Sec. 35-386. - Computations.
The extra strength surcharge shall be calculated in accordance with the provisions of the applicable rate ordinance (the same being incorporated by reference) using the following limits and calculations: (1) BOD in excess of two hundred fifty (250) mg/L (2) COD in excess of four hundred (400) mg/L (3) TSS in excess of two hundred fifty (250) mg/L (4) O&G in excess of fifty (50) mg/L _____ SURCHARGE | = | [(BOD x - 250 mg/L) (8.34) (V) (A)] or [(COD x - 400 mg/L) (8.34) (V) (A)] + [(TSS x - 250 mg/L) (8.34) (V) (B)] + [(O&Gx × 50 mg/L) (8.34) (V) (C)] Where: | BOD x | = | concentration of BOD in mg/L COD x | = | concentration of COD in mg/L TSS x | = | concentration of TSS in mg/L O&G x | = | concentration of O&G in mg/L 8.34 | = | weight of one gallon of water, pounds V | = | flow in million gallons per month A | = | unit charge for BOD/COD B | = | unit charge for TSS C | = | unit charge for O&G _____
(Ord. No. 19,895, § 14.2, 12-21-07)