For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-55 — Access to buildings

The Little Rock City Code, Revised 1988 (Supp. No. 83: codified through Ordinance No. 22,703, enacted December 16, 2025) · Little Rock City Code § 8-55

Corpus is an independent public-information project, not the official City of Little Rock website. Stable reference: corpuslaw.us/code/c5080446-cdab-4a0c-9f0a-5747bd2097f7

Sec. 8-55. - Access to buildings.

(a) Accessibility to buildings shall be provided from right-of-way and parking areas by means of a pathway leading to at least one (1) entrance generally used by the public. Such pathway shall have been cleared of nonstructural items related to construction activity, prior to the opening of the building to the general public. Where curbs exist along such pathway, as between a parking lot surface and a sidewalk surface, inclined curb approaches or curb cuts having a gradient of not more than one (1) foot in twelve (12) feet and a width of not less than four (4) feet shall be provided for access by wheelchairs. The sidewalls of a curb cut shall not exceed an inclination ratio of 8:1. (b) A parking lot serving each such entrance pathway shall have a number of level parking spaces, as set forth in the following table, identified by above-grade signs as being reserved for physically handicapped persons. Each parking space so reserved shall be not less than twelve (12) feet in width. Such spaces shall be level or have a maximum slope of two (2) percent, (50:1 ratio) and marked with the international symbol of access. PARKING SPACES FOR HANDICAPPED Total Spaces in Lot | Required Number of Reserved Spaces up to 25 | 1 26 to 50 | 2 51 to 75 | 3 76 to 100 | 4 100 to 150 | 5 151 to 200 | 6 201 to 300 | 7 301 to 400 | 8 401 to 500 | 9 501 to 1000 | 2% of total over 1000 | 20 plus 1 for each 100 over 1000 Parking spaces for the physically handicapped shall be located as close as possible to elevators, ramps, walkways and entrances. Parking spaces should be located so that physically handicapped persons are not compelled to wheel or walk behind parked cars to reach entrances, ramps, walkways and elevators. (c) All buildings that have their main floor level above or below ground level shall have a least one (1) ramp at a public entrance to the building accessible and available for use by physically handicapped persons using wheelchairs, braces, crutches or other devices. Ramps for use by physically handicapped persons shall not have a slope greater than one (1) foot rise in twelve (12) feet, or eight and one-third (8⅓) percent, or four (4) degrees fifty (50) minutes. Ramps shall have landings at the top and bottom. Top landing will be a minimum of five (5) feet by five (5) feet with one and one-half (1½) feet of clearance on either side of a door that swings outward onto the landing. The bottom landing shall provide at least six (6) feet of straight clearance uninterrupted by gratings, drain covers, or other change in level. (d) Landings shall be provided at twenty-foot intervals for a ramp over twenty (20) feet in length. Each landing shall have a minimum length of five (5) feet except the bottom landing which shall have a length of six (6) feet. Ramps over twenty (20) feet in length shall not exceed a slope ratio of 20:1 (five (5) percent). (e) Projections into the required ramp and landing width shall be limited to handrails (three and one-half (3½) inches maximum) and stringers (one and one-half (1½) inches maximum). Doors opening onto a ramp or landing shall not reduce the clear width to less than forty-two (42) inches. Where changes in elevations exist in exit access corridors, exits and exit discharges, ramps shall be used when the difference in elevation is less than twenty-one (21) inches. Handrails shall be provided on both sides of a ramp, shall be between thirty (30) and thirty-four (34) inches high and extend one (1) foot beyond top and bottom steps (except where the extension would in itself create a hazard). (f) All controls, emergency equipment, alarms, etc. shall be mounted no higher than forty-eight (48) inches. (g) All alarms shall be both visual and audible; visual alarms will be designed to raise the overall light level sharply and be visible from all public areas (such as library stacks, or individual reading rooms). (h) If the use of an exit is controlled by such devices as narrow checkout lanes, turnstiles, etc., there shall be at least one (1) lane of thirty-two (32) inches of clear opening path of exit which will be open and available for use whenever other controlled exits are available for use. "Express lanes" or other exits shall provide thirty-two (32) inches clear width in addition to other controlled exits. (i) At least one (1) main entrance door designed for use by the handicapped and equipped with door closer shall have kickplates extending the width of the door of at least twelve (12) inches width. This main entrance door shall be operable by single effort and opening pressure shall not exceed eight (8) pounds pressure.

(Ord. No. 13,478, § 2(517.3), 8-1-78)

Ask a question about Little Rock law

Corpus searches the Little Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.