Sec. 18-373. - Other regulations.

(a) Water heaters. Water heaters shall not be installed in any location where flammable vapors are likely to be present, unless the design, operation and installation are such to eliminate the probable ignition of the flammable vapors. Water heaters installed where flammable vapors are likely shall be installed so that all burners and/or ignition devices are located not less than 18 inches above the floor. All other gas appliances shall be installed per manufacturer's instructions. (b) Gas meters. Gas meters shall be located at least three feet from any source of ignition. (c) Downstream from a water closet. When fixtures, open site drains, floor drains and other openings to the drainage system discharge downstream from a water closet, each fixture discharging downstream shall be vented individually, with exception of another water closet which shall be otherwise vented in accordance to other sections of this Code. (d) Wet venting. Wet venting shall be limited to the same floor only. (e) Water services. All water services on new construction (residential and/or commercial) shall be installed under the footing. (f) Gas shut off for fireplaces. All fireplace units with log lighters shall have a log lighter valve, or appliance valve, installed on the outside of the fireplace unit. (g) Closets on three-inch drain. No more than two water closets shall drain into a three-inch DWV drain line. (h) Reduced pressure zone (RPZ) valves. All reduced pressure zone (RPZ) valves, either lawn sprinkler or structural, shall be installed as close as possible to the structure being served. At no time shall it be installed in a right-of-way. (i) Lawn sprinkler. All lawn sprinkler systems shall be protected by an RPZ valve. (j) Double compartment sinks. All double compartment sinks shall have a "P" trap installed for each compartment. (k) Gas pipe grounding. When gas pipe is installed new and/or repaired, the installer or repair person shall be responsible for the proper grounding of the gas pipe system.

(Ord. No. 7743, § 1, 9-26-05)

Ask a question about North Little Rock law

Corpus searches the North Little Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.