Sec. 22-68. - Ventilation.
(a) For attic moisture control, minimum standard requirements for an effective air flow of five-tenths cubic foot per minute of the net free per-square-foot ceiling areas shall be required. (b) Soffit vents will be installed every eight feet on all hip roofs. These can be either eight by 16 vents or two-inch side running vent. Both must have bug screen or an approved equal. (c) Exhaust ventilation may be accomplished in numerous ways, such as statis gable loovers, power attic ventilation, cupolas, etc., as long as it performs the minimum requirement of subsection (a) of this section.
(Code 1973, § 16½-13)