§ 4-18 — Stabilized adobe and earthen masonry
Municipal Code of the City of Avondale, Arizona (Codified through Ordinance No. 2021-0726, adopted July 6, 2026 (Supp. No. 38, Update 1)) · Avondale Municipal Code § 4-18
Corpus is an independent public-information project, not the official City of Avondale website. Stable reference: corpuslaw.us/code/cbfbf562-5cb4-4f4c-b82b-a2f2b8bd38ab
4-18. - Stabilized adobe and earthen masonry.
Scope: This section governs the use, design, testing, and installation of stabilized adobe and earthen masonry units in all building types and occupancies regulated under the 2024 International Building Code (IBC) and 2024 International Residential Code (IRC) within the City of Avondale. (a) Material Standards. Only stabilized adobe units meeting specific criteria are permitted. The units must achieve a minimum average compressive strength of 700 psi, with no individual unit below 600 psi, tested in accordance with ASTM C1713 or an approved equivalent. The modulus of rupture shall be a minimum of 75 psi, tested per ASTM C1713 or an approved equivalent. Moisture absorption shall not exceed 8 percent by weight when tested under applicable ASTM standards. Unstabilized adobe or earthen masonry is strictly prohibited. (b) Design and Submittal Requirements. All structural designs, including foundations, walls, bond beams, lintels, and anchorage, must be prepared by a registered design professional. Applicants are required to submit structural calculations demonstrating compliance with IBC or IRC requirements, soil composition and mix reports verifying clay and stabilizer content, and material testing results confirming compliance with the compressive strength, modulus of rupture, and absorption limits. All designs and submittals are subject to approval by the Chief Building Official prior to commencement of construction, in accordance with IBC Sections 107.1, 1704.2 and IRC Section R106.1. (c) Construction Requirements. All adobe or stabilized earthen masonry walls shall be supported on continuous concrete footings or foundation systems designed and constructed in accordance with applicable provisions of the 2024 International Building Code (IBC) or the 2024 International Residential Code (IRC) for structures. Footings shall be designed to safely support the loads imposed by the masonry walls and any roof or floor loads, consistent with soil conditions, wall height, and structural design. Reinforcement, anchorage, and lateral support shall comply with the applicable IBC or IRC provisions for masonry construction. (d) Inspection and Verification. Material testing shall be conducted on random samples from each batch of adobe units to ensure compliance with the approved standards. In addition, on-site inspections may be required by the Chief Building Official to verify that construction aligns with the approved designs and that all ASTM testing requirements have been satisfied. (e) Prohibited Uses. Unstabilized adobe is strictly prohibited for any portion of a building. Adobe or earthen masonry shall not be used for foundations, basement walls, or load-bearing elements located below the finished floor unless such use is specifically designed by a registered design professional and approved by the Chief Building Official. (Ord. No. 2046-1225, § 6, 12-1-25)
Ask a question about Avondale law
Corpus searches the Avondale sections it holds and shows the ones that match, with their citations. Free, no sign-in.