§ 8-44 — Standards for manufactured homes
Municipal Code of the City of Avondale, Arizona (Codified through Ordinance No. 2021-0726, adopted July 6, 2026 (Supp. No. 38, Update 1)) · Avondale Municipal Code § 8-44
Corpus is an independent public-information project, not the official City of Avondale website. Stable reference: corpuslaw.us/code/aadc9916-d532-44ab-837a-dbf2e80dc390
8-44 - Standards for manufactured homes.
(a) No manufactured home shall be placed in a floodway, except to replace an existing manufactured home park or existing manufactured home subdivision. (b) All manufactured homes that are placed on site or substantially improved shall: (1) Be elevated so that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is at or above the regulatory flood elevation; and (2) Be securely anchored to an adequately anchored foundation system to resist flotation, collapse or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. (3) Be installed in compliance with the manufacturer specifications. (c) Upon completion of installation of the manufactured home, certification by a registered professional engineer or surveyor that the elevation requirements of this section have been satisfied shall be provided to the Floodplain Administrator for verification.
(Ord. No. 1673-1018, § 2, 10-15-18; Ord. No. 2008-0325, § 6, 3-24-25)
Ask a question about Avondale law
Corpus searches the Avondale sections it holds and shows the ones that match, with their citations. Free, no sign-in.