§ 13.09.030 — General requirements
Municipal Code of the City of Bullhead City, Arizona (Codified through Ordinance No. 2026-14, enacted August 17, 2026. (Supp. No. 75)) · Bullhead City Municipal Code § 13.09.030
Corpus is an independent public-information project, not the official City of Bullhead City website. Stable reference: corpuslaw.us/code/46736310-b892-4d85-8e28-97b364bd3c80
13.09.030 - General requirements.
A. Requirements. All food service facilities are required to have a gravity grease interceptor installed outside the facility. The requirements of this chapter are in addition to any applicable requirements for the International Building and Plumbing Codes adopted by the city, and any pretreatment requirement adopted by the city for protection of the city's water reclamation plant. 1. New facilities. On or after the effective date of this chapter, food service and facilities which are newly proposed, constructed, or permitted, or existing facilities which are expanded or renovated to include a food service facility, where such facility did not previously exist, shall be required to install, operate, and maintain a gravity grease interceptor according to the requirements contained in this chapter. Gravity grease interceptors shall be installed and permitted prior to the issuance of a certificate of occupancy. 2. Existing facilities. For the purpose of sizing and installation of grease interceptors, all food service facilities existing within the city prior to the effective date of this ordinance shall be permitted to operate and maintain existing gravity grease interceptors provided their gravity grease interceptors are in compliance with the criteria for the individual interceptor as defined in this chapter. B. Compliance. On or after the effective date of this ordinance, the city may require an existing food service facility to install, operate, and maintain a new gravity grease interceptor that complies with the requirements of this chapter or to modify or repair any noncompliant plumbing or existing gravity grease interceptor or grease trap within one hundred eighty days of written notification by the city when any one or more of the following conditions exists: 1. The facility is found to be discharging FOG in quantities greater than one hundred milligrams per liter in the facility effluent sample. 2. The facility does not have a gravity grease interceptor(s). 3. The facility has an undersized, irreparable or defective gravity grease interceptor(s). 4. When remodeling or renovation of an existing facility where a plumbing permit is issued by the city. 5. The existing facility effluent causes sewer line blockage, sanitary sewer overflows (SOS), or stoppage that requires the city to increase standard maintenance. C. Plumbing connections. All plumbing connections shall be located outside the food service facilities lateral sewer line between all fixtures which may introduce FOG into the sewer system and the connection to the city's wastewater collection system. Such fixtures shall include, but not be limited to hand, prep, and mop sinks, dishwashers, garbage disposals, automatic hood wash units, floor drains in food preparation and stage areas, and any other fixture which is determined to be a potential source of FOG. Wastewater from sanitary facilities and other similar fixtures shall not be introduced into gravity grease interceptor(s) under any circumstance. D. Gravity grease interceptors. Gravity grease interceptors shall be installed at all new food service facilities. All new and existing gravity grease interceptors shall meet the following criteria: 1. Interceptor design and location. Gravity grease interceptors shall have a minimum of two compartments and shall be capable of separation and retention of FOG and storage of settled solids. Gravity grease interceptor designs shall conform to the requirements of the International Building Code (plumbing section) adopted by the city. A control manhole over each compartment for monitoring and purposes shall be required and installed at the owners/operator's sole expense. Covers shall have a gas tight fit. The gravity grease interceptor shall be designed, constructed, and traffic rated if located in a traffic area. Flow control devices shall be required where the water flow through the gravity grease interceptor may exceed its rated flow. Interceptors shall be installed in a location outside of the building and which provides easy access at all times for inspections, cleaning, and maintenance, including pumping. Nothing shall be stored on top or built over the gravity grease interceptor covers. A sampling port of six-inch discharging tee shall be installed. 2. Capacity. Gravity grease interceptor capacity calculations shall be performed by each food service facility based on size and type of operation according to the formula contained in Section 1003.3.5.1 International Plumbing Code adopted by the city, and the sizing methods contained in the standard. Minimum capacity of any one unit shall be eight hundred gallons. Maximum capacity of any one unit shall be one thousand two hundred fifty gallons. Where sufficient capacity cannot be achieved within a single unit, installation of gravity grease interceptors in series is required. Prior to the installation of the gravity grease interceptors(s), the city shall approve the gravity grease interceptor(s) capacity calculations. The capacity of the gravity grease interceptor(s) required for food manufacturing or processing facilities which are not covered by the International Building Code and Plumbing Codes adopted by the city, shall be approved by the city according to the mass and type of food prepared, the wastewater volume produced from food preparation or manufacture, total hours of operation per day and a load factor depending on the installed equipment. 3. Cleaning, pumping and maintenance. Each food service facility shall be solely responsible for the cost of the gravity grease interceptor installation, inspection, cleaning, pumping, and maintenance. All food service facilities with gravity grease interceptors shall contract with and utilize a FOG hauler. Pumping services shall include the initial complete removal of all contents, including floating materials, wastewater, and bottom sledges and solids from the interceptor. The return of gray water back into the gravity grease interceptor from which the wastes were removed is strictly prohibited. Gravity grease interceptor cleaning shall include scraping excessive solids from the walls, floors, baffles, and all pipe work. It shall be the responsibility of each food service facility to inspect its gravity grease interceptor during the pumping procedure to ensure it is properly cleaned out and all fittings and fixtures inside the interceptor are in good working condition and functioning properly. 4. Pumping frequency. Each food service facility shall have its gravity grease interceptor(s) pumped at a minimum frequency of once every calendar month. In addition to required monthly pumping, the city may determine by monthly or bi-monthly core sampling inspection that additional pumping is required or more interceptor space is needed if the following criteria cannot be met with the existing FOG interceptor space: a. When the floatable grease layer exceeds six inches in depth as measured by an approved dipping method. b. When the settled solids layer exceeds eight inches in depth as measured by an approved dipping method. c. When the total volume of captured FOG and solid material displaces more than twenty percent of the capacity of the interceptor as calculated using an approved dipping method. d. When the interceptor is not retaining or capturing FOG or the removal efficiency of the device, as determined through sampling an analysis, is less than eighty percent. 5. Inspection. The city shall inspect gravity grease interceptors as necessary to assure compliance with this chapter as well as adherence to proper cleaning and maintenance schedules. 6. Repairs. The food service facility shall be responsible for the cost and scheduling of all repairs to its gravity grease interceptor(s). Repairs required by the city shall be completed within fourteen calendar days after the date of written notice of required repairs is received by the food service facility unless a different schedule is approved by the city in writing. 7. Disposal. Waste removed from any gravity grease interceptor shall be disposed of at a facility permitted to receive such waste. Neither FOG nor other solid material removed from a gravity grease interceptor shall be returned to any gravity grease interceptor, private sewer line or to any portion of the city's wastewater collection system or water reclamation facilities without prior written approval of the city utilities director. 8. Record keeping. The food service facility shall maintain records including the date and time of all cleaning and maintenance, details of any repairs required, and dates of repairs for each gravity grease interceptor in a bound logbook and shall make the logbook available for inspection by the city on request. Additionally, each food service facility shall maintain a file on site, and available at all times for inspection and review by the city, which contains the following information: a. The as-built drawings of the plumbing system. b. Records of all inspections. c. Receipts of all repairs. d. Log of pumping activities. e. Log of maintenance activities. f. FOG hauler information. g. Disposal information. h. Records shall be kept for a period of three years from time of cleaning or repair. E. FOG interceptors. FOG interceptors shall be constructed of impervious material capable of withstanding abrupt and extreme changes in temperature. They shall be of substantial construction, watertight, and equipped with easily removable covers which, when bolted in place, shall be gas tight and watertight. An approved control manhole or inspection box for monitoring purpose shall be required and installed at the owners/operator's sole expense. F. Variance procedure. If a food service facility determines that monthly pumping of the gravity grease interceptor is unnecessary in order to remain in compliance with the criteria of this section, the food service facility may make written application for a variance from the monthly pumping requirement to the city. The variance procedure shall be as follows: 1. The food service facility shall submit an application for a variance on a form provided by the city along with the appropriate application fee if required. The application shall include the next scheduled date and time for pumping and cleaning of the gravity grease interceptor(s). 2. The city shall observe the pump out procedure and inspect the gravity grease interceptor(s) on the scheduled date and time. 3. If the gravity grease interceptor(s) is in good working condition during the initial inspection, the city shall re-inspect the gravity grease interceptor(s) approximately one month after the initial inspection. If there is less than four inches of surface grease and less than six inches of bottom solids at the time of this re-inspection, the grease interceptors) will not need to be pumped out at that time. 4. After the initial re-inspection, the city shall inspect the gravity grease interceptor(s) at intervals of approximately every ten working days to determine the FOG and solids levels using a dipping method approved by the city. 5. When either the level of FOG reaches six inches or the level of solids reaches eight inches, the city shall use the number of days from the initial pumping date to the final re-inspection date as the new pumping frequency requirement to be included in the variance granted. 6. At all times, pump-out and cleaning of a gravity grease interceptor(s) shall be required at least once every one hundred eighty days.
(Ord. No. 2024-04, § 3, 2-6-2024)
Ask a question about Bullhead City law
Corpus searches the Bullhead City sections it holds and shows the ones that match, with their citations. Free, no sign-in.