§ 15.20.020 — National Electrical Code—Adopted—Amendments
Municipal Code of the City of Bullhead City, Arizona (Codified through Ordinance No. 2026-14, enacted August 17, 2026. (Supp. No. 75)) · Bullhead City Municipal Code § 15.20.020
Corpus is an independent public-information project, not the official City of Bullhead City website. Stable reference: corpuslaw.us/code/0596b1fc-f0a9-436a-b25f-06f68104646e
15.20.020 - National Electrical Code—Adopted—Amendments.
A. The 2017 Edition of the National Electrical Code, copyrighted by International Code Council, Inc., shall be adopted, except as revised as follows: Article 90 Introduction (Add) Section 90.10 Administration. (Add) Section 90.10.1 Schedule of permit fees. The fee policy is established in City Chapter 15.12.010, Section 109.2 Schedule of permit fees. (Add) Section 90.10.2 Refunds. The fee refund policy is established in City Chapter 15.12.010, Section 109.6 Refunds. (Add) Section 90.10.3 Board of Appeals. The board of appeals policy is established in Section 113 of the 2018 International Building Code. (Add) Section 90.10.4 Violations. The violations policy is established in Section 114 of the 2018 International Building Code. (Add) Section 90.10.5 Stop Work Orders. The stop work order policy is established in Section 115 of the 2018 International Building Code. Section 110.1 Scope. (Add) Section 110.1.1 Services above 400 amperes. Electrical plans submitted for services above 400 amperes shall be submitted and sealed by an Arizona licensed registrant. A qualified AZ Registrar of Contractors licensed contractor is required for services above 400 amperes. Section 210.12 Arc-Fault Circuit-Interrupter Protection (A) Dwelling Units. All 120-volt, single-phase, 15- and 20-ampere outlets or devices installed in bedrooms shall be protected by any of the means described in 210.12(A)(1) through (6): (D) Branch Circuit Extensions or Modifications—Dwelling Units and Dormitory Units. In any of the areas specified in 210.12(A) or (B), where branch-circuit wiring is modified, replaced, or extended, the branch circuit may be protected by one of the following: (Remain—items 1 and 2) Section 230.70 General. (Add) (D) Shunt Trip Devices. (1) Location. The shunt trip may be located in a central control station in a high-rise building, mall or atrium when approved by the fire department. (2) Supply. The branch circuit supplying power for the shunt trip device shall be connected to the supply side of the main service disconnecting means and be a maximum conductor size of No. 12 AWG copper. (3) Marking. Where a shunt trip station is installed outside the building or structure served, the station shall be a 1-foot (0.093 sq m.) square, colored yellow and have black lettering 1 inch (25.4 mm) high with a ¼ inch (6.35 mm) stroke describing it as the "Main Electrical Disconnect" in accordance with building department requirements. (4) Enclosure. The shunt trip device shall be located inside an approved metal enclosure and shall have a hinged cover that can be locked from the exterior by means of an exposed shaft-type locking device. The shaft of the locking device shall be no larger than 5/16 inch (7.94 mm) in diameter. (5) Type. The shunt trip device shall be a momentary contact type switch. Section 250.50 Grounding Electrode System. (Add) Two means of grounding are required. The primary grounding electrode shall be an 8 foot (2438 mm) long by 5/8 inch (15.88 mm) diameter driven rod. All supplemental grounding systems are open to any type allowed by the NEC. Section 406.12 Tamper-Resistant Receptacles. (1) May be provided in One- and Two-Family dwelling units. Shall be provided in all other dwelling units in all areas specified in 210.52 and 550.13.
(Ord. No. 2024-09, § 1, 4-16-2024; Ord 2008-18 § 1 (part))
Ask a question about Bullhead City law
Corpus searches the Bullhead City sections it holds and shows the ones that match, with their citations. Free, no sign-in.