§ 15.30.010 — International Swimming Pool and Spa Code
Municipal Code of the City of Bullhead City, Arizona (Codified through Ordinance No. 2026-14, enacted August 17, 2026. (Supp. No. 75)) · Bullhead City Municipal Code § 15.30.010
Corpus is an independent public-information project, not the official City of Bullhead City website. Stable reference: corpuslaw.us/code/28283f95-a5e6-49eb-9fcd-a077fc570fb3
15.30.010 - International Swimming Pool and Spa Code.
A. The 2018 Edition of the International Swimming Pool and Spa Code, copyrighted by International Code Council, Inc., shall be adopted, except as revised as follows: Section 101.1 Title. These regulations shall be known as the Swimming Pool and Spa Code of The City of Bullhead City hereinafter referred to as "this code." Section 105.1 When required. (Add) Section 105.1.1 ADEQ approval. Public swimming pools, spas and other aquatic recreation features are subject to additional permitting requirements of the Arizona Department of Environmental Quality (ADEQ). ADEQ requirements supersede this code. Section 105.3 Construction documents. (Add) 105.3.1 Documents prepared by a registered design professional. Not less than one set shall bear an original seal and signature of the registered design professional. An electronic signature, as an option to a permanently legible signature, in accordance with AZ Board of Technical Registration R4-30-304(G), is acceptable for all professional documents. Section 105.6.2 Fee schedule. The fee policy is established in City Chapter 15.12.010, Section 109.2 Schedule of permit fees. Section 105.6.3 Fee refunds. The refund policy is established in City Chapter 15.12.010, Section 109.6 Refunds. Section 107 Violations. The violations policy is established in Section 114 of the 2018 International Building Code. Section 107.5 Stop work orders. The stop work order policy is established in Section 115 of the 2018 International Building Code. Section 108 Board of appeals. The board of appeals policy is established in Section 113 of the 2018 International Building Code. (Delete) Section 303 Energy. Section 305 Barrier Requirements. Section 305.1 General. The provisions of this section shall apply to the design of barriers for restricting entry into areas having pools and spas whether below ground or above ground. Where spas or hot tubs are equipped with a lockable safety cover complying with ASTM F1346 and swimming pools are protected by a motorized safety pool cover that complies with ASTM F1346 that requires the operation of a key switch which meets the ASTM emergency standards 13-89 and which does not require manual operation other than the use of the key switch, the areas where those spas, hot tubs or pools are located shall not be required to comply with amended Sections 305.2 through 305.5. 305.2 Outdoor swimming pools and spas. Outdoor pools and spas and indoor pools and spas shall be surrounded by a barrier that complies with Sections 305.2.1 through 305.5 Commercial and Multi-Family Locations: An interior barrier fence between the buildings and the pool/spa is required. Single Family Residential Locations: Where the barrier requirements of sections 305.2.1 through 305.5 can not be achieved an inner barrier fence around the entire pool/spa is required. Section 305.2.1 Barrier height and clearances. 1. The top of the barrier shall be not less than 60 inches (1524 mm) above grade where measured on the side of the barrier that faces away from the pool or spa. Such height shall exist around the entire perimeter of the barrier and for a distance of 48 inches (1219.2 mm) of the barrier and for a distance of 48 inches (1219.2 mm) measured horizontally from the outside of the required barrier from any natural or man-made object that would effectively reduce the 60 inch (1524 mm) non-climbable height of the barrier. (Remain—items 2, 3 and 4) Section 305.3.2 Double or multiple gates. Double gates or multiple gates shall have no fewer than one leaf secured in place, and the adjacent leaf shall be secured with a self-latching device. The gate and barrier shall not have openings larger than ½ inch (12.7 mm) within 24 inches (609.6 mm) of the latch release mechanism. The self-latching device shall comply with the requirements of Section 305.3.3. Gates shall remain locked when not in use. Section 305.3.3 Latches. Where the release mechanism of the self-latching device is located less than 54 inches (1372 mm) from grade, the release mechanism shall be located on the pool or spa side of the gate not less than 5 inches (127 mm) below the top of the gate, and the gate and barrier shall not have openings greater than ½ inch (12.7 mm) within 24 inches (609.6 mm) of the release mechanism. Section 305.4 Structure wall as a barrier. (Remain—items 1, 2 and 3) (Add) 4. All ground level doors or other doors with direct access to the swimming pool or other contained body of water shall be equipped with a self-latching device that meets the requirements of 305.3.3 amended. Emergency escape or rescue windows from sleeping rooms with access to the swimming pool or other contained body of water shall be equipped with a latching device not less than 54 inches (1372 mm) above the floor. All other openable dwelling unit or guest room windows with similar access shall be equipped with a screwed in place wire mesh screen, or a keyed lock that prevents opening the window more than 4 inches (102 mm), or a latching device located not less than 54 inches (1372 mm) above the floor. (Reference A.R.S. § 36-68) (Add) 5. Between the swimming pool or other contained body of water and the residence or living area, a minimum four foot (1219.2 mm) wall, fence or barrier to the pool area which meets all of the requirements of amended Sections 305.2 through 305.3. (Delete) Section 305.6 Natural barriers. (Delete) Section 305.7 Natural topography.
(Ord. No. 2024-09, § 1, 4-16-2024)
Ask a question about Bullhead City law
Corpus searches the Bullhead City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
