§ 15.24.020 — Amendments to the International Fire Code, 2024 Edition

Municipal Code of the City of Cottonwood, Arizona (Codified through Ordinance No. 767, passed April 21, 2026. (Supp. No. 26, (8/26), Update 2)) · Cottonwood Municipal Code § 15.24.020

Corpus is an independent public-information project, not the official City of Cottonwood website. Stable reference: corpuslaw.us/code/463ff565-ef74-475f-af84-06fcbc651307

15.24.020 - Amendments to the International Fire Code, 2024 Edition.

The International Fire Code, 2024 Edition, is amended as follows: A. Chapter 3, Open Flames, Section 308.1.5, Open-flame devices in wildfire risk areas, is amended to read as follows: 308.1.5 Open-flame devices in wildfire risk areas. Torches and other devices, machines or processes liable to start and or cause a fire shall not be operated or used in high fire risk areas or high-risk fire seasons within the City of Cottonwood, this will include to prohibit the use of all aerial Fireworks (Exception: Public Fireworks displays permitted by fire code official) and aerial Sky Lanterns that are made of materials that can easily catch on fire. These provisions shall meet the additional requirements as listed in Chapter 56 of the International Fire Code. B. Chapter 5, Fire Service Features. Section 505.1, Address identification, is amended to read as follows: 505.1 Address identification. New and existing buildings shall have approved address numbers, building numbers or building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 6 inches high with a minimum stroke width of 0.5 inch. Larger numbers may be required by the fire code official to facilitate emergency response. C. Chapter 9, Fire Protection Systems, Section 901.2, Construction documents, is amended by adding the following: Automatic sprinkler system plans shall be submitted bearing a review certification and signature of a minimum level III NICET Certified Engineering Technician or Arizona registrant. Fire sprinkler plans for high-piled combustible storage occupancies shall require a registered fire protection engineer stamp. Fire alarm system plans shall be submitted bearing a review certification and signature of a minimum level III NICET Technician or Arizona registrant. D. Sections 903.2—903.2.11.3 Where required: are deleted and replaced with: Section 903.2 Approved automatic fire sprinkler systems-Where required: An automatic fire sprinkler system shall be installed throughout any: • H, I & R occupancy. • Multistory structure (including basements). • A, B, E, F, M, S & U occupancy of more than 1,000 square feet. • Structure where the required fire flow cannot be provided. • At any other time as determined by the Fire Code Official. • Such systems shall be designed and installed in accordance with: • IFC standard 903.3.1.1 (NFPA 13) for Group A, B, E, F, H, I, M, R, S and U occupancies, • IFC standard 903.3.1.2 (NFPA 13-R) for residential occupancies four stories or less, and • IFC standard 903.3.1.3 (NFPA 13-D) for R-3 & R-4 occupancies (one- and two-family dwellings). Exceptions: l. Detached non-combustible carports or shade canopies. 2. Detached non-combustible canopies used exclusively for automotive, motor fuel-dispensing stations for private passenger vehicles not exceeding 5,000 square feet. 3. When in the opinion of the Fire Code Official, and subject to the approval of the Building Official, fire sprinklers may be omitted in rooms or areas as follows: • When sprinklers are considered undesirable because of the nature of the contents or in rooms or areas, which are of noncombustible construction with wholly noncombustible contents and, which are not exposed by other areas. Fire sprinklers shall not be omitted from any room merely because it is damp, of fire-resistive construction or if it contains electrical equipment. (i.e., Sprinklers shall not be installed when the application of water, or flame and water may constitute a serious life or fire hazard, as in the manufacture or storage of quantities of aluminum powder, calcium carbide, calcium phosphide, rpetallic sodium, and potassium, quicklime, magnesium powder and sodium peroxide.) • Safe deposit or vaults of fire-resistive construction, when used for the storage of records, files and other documents, when stored in metal cabinets. • Communications equipment areas under the exclusive control of a public communications utility agency provided it is installed in accordance with NFPA standards. • Other approved automatic fire-extinguishing systems may be installed to protect special hazards or occupancies in lieu of automatic fire sprinklers. Existing buildings: Existing buildings (occupancies) are required to comply with the provisions of 903.2 when any of the following apply: 1. One or more additions are made to any occupancy and the aggregate of the addition(s) exceeds 50% of the square footage of the original building (at the time of this ordinance) or 1,000 square feet, whichever is less; or an occupancy which undergoes a partial or complete renovation when the cost of the renovation exceeds 50% of the value of the original building as determined by the current "Building Fee Schedule Cost Per Square Foot" table published by the International Code Council and adopted by the City of Cottonwood. 2. Any structure over 1000 square feet, regardless of occupancy classification, and all R occupancies, which are relocated to a new site, shall require a Fire Sprinkler system to be installed throughout the building in accordance with the applicable NFPA standards for the building classification. 3. Any addition or renovation to a building, or occupancy classification change, which results in a structure that exceeds the available fire flow. 4. Any addition or renovation to a building or an occupancy classification change, when it is determined by the Fire Code Official to present a greater risk of fire or danger to the safety of occupants than before the addition, change or occupancy classification change. 5. Any building undergoing a change of occupancy when the new occupancy classification is H, I, R or any mixed use which includes an R occupancy, Fl & SI occupancies in excess of 1500 square feet and A1, A2 & A3 occupancies with an occupant load of greater than 100 persons. E. Chapter 56, Explosives and Fireworks, Section 5601.2.4, Financial responsibility, is amended to read as follows: 5601.2.4 Financial responsibility. Before a permit is issued, as required by Section 5601.2, the applicant shall file with the jurisdiction a corporate surety bond in the principal sum of $5,000,000 (five million dollars) or a public liability insurance policy for the same amount, for the purpose of the payment of all damages to persons or property which arise from, or are caused by, the conduct of any act authorized by the permit upon which any judicial judgment results. The fire code official is authorized to specify a greater or lesser amount when, in his or her opinion, conditions at the location of use indicate a greater or lesser amount is required. Government entities shall be exempt from this bond requirement. F. Chapter 56, Explosives and Fireworks, Section 5601.2.4.1, Blasting, is amended to read as follows: 5601.2.4.1 Blasting. Before approval to do blasting is issued, the applicant for approval shall file a bond or submit a certificate of insurance in the amount of $5,000,000 (five million dollars) in each case to indemnify the City of Cottonwood against any and all damages arising from permitted blasting. All blasting permit applicants shall have a valid Certificate of Fitness card issued by a jurisdiction deemed acceptable by the Fire Code Official. G. Chapter 56, Explosives and Fireworks, Section 5601.4, Qualifications, is amended to read as follows: 5601.4 Qualifications. A current pyrotechnics Shooters Certificate or Certificate of Fitness for pyrotechnics issued by the City of Phoenix or the City of Tucson be held by at least one individual on the shooting crew during the fireworks display.

(Ord. No. 640, § 11, 6-19-2018; Ord. No. 662, § 11, 5-21-2019; Ord. No. 761, § 16, 5-20-2025)

Ask a question about Cottonwood law

Corpus searches the Cottonwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.