15.52.040 - Material testing.
The material testing requirements shown below are for public improvements only; the city inspector shall select testing locations and may increase or decrease the frequency of the tests. Cost of materials testing shall be the responsibility of the property developer and not the city of Cottonwood. A third party testing laboratory, agreed to by the city engineer, shall be used for all material testing. Testing Frequency Concrete | 1 set of 4 cylinders per 50 CY. Embankment | 1 density test per 500 LF per lift. Subgrade | 1 density test per 500 LF. Base Course | 1 density test per 500 LF; one gradation check. Asphalt | 1 density per 500 LF in each lane; 1 extraction per paving day; 1 gradation check per paving day. Trench Backfill | For MAG 601, Type I backfill. Density test at spring line; 1′ above pipe and each 2′ depth increment above pipe for each 500 feet of pipe. Testing is required for public sewer and utilities within 10 feet of a public street. Sewer | Testing per MAG, Section 615. Video inspection of all public sanitary sewer is required.
(Ord. 362 § 2(part), 1998)