18.08.05 - Provisions for flood hazard reduction.

A. Standards of Construction. In all special flood hazard areas the following standards shall apply: 1. Anchoring. a. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; b. All manufactured homes shall meet the anchoring standards of Section 18.08.05.E.2. 2. Construction Materials and Methods. a. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; b. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage; c. Within zones AH or AO, adequate drainage paths shall be constructed around structures on slopes to guide floodwaters around and away from proposed structures. 3. Elevation and Floodproofing. a. Residential Construction. Residential construction, as well as new or substantial improvements, shall have the lowest floor, including basement, elevated to or above the regulatory flood elevation. 1. In a zone AO, the base flood election is determined from the FIRM panel. If unspecified, the required elevation is at minimum two feet above the highest adjacent grade. 2. In a zone A where the base flood election has not been determined, the base flood election is determined by the criteria set out in Section 18.08.04.B.3. 3. In zones AE and AH, the base flood election is determined from the FIS and/or FIRM. 4. A garage attached to a residential structure, constructed with the garage floor slab below the regulatory flood elevation, must be designed to allow for the automatic entry and exit of flood waters and must be used solely for parking, access and/or storage. See section 18.08.05.A.3.d.1. or 2. Upon completion of the structure, certification by a registered professional engineer or surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the floodplain administrator for verification. b. Nonresidential Construction. Nonresidential construction, as well as new or substantial improvements, shall have the lowest floor either elevated to conform with Section 18.08.05.A.3.a.1, 2., or 3. as appropriate, or, together with attendant utility and sanitary facilities, 1. Be floodproofed below the elevation recommended under Section 18.08.05.A.3.a.1., 2., or 3 as appropriate so that the structure is watertight with walls substantially impermeable to the passage of water; and 2. Have structural components capable of resisting hydrodynamic and hydrostatic loads and effects of buoyancy. Upon completion of the structure, certification by a registered professional engineer or surveyor that the elevation requirements of the lowest floor, including basement, of this section have been satisfied shall be provided to the floodplain administrator for verification; or certification by a registered professional engineer or architect that the floodproofing standards of this section are satisfied shall be provided to the floodplain administrator for verification. c. Manufactured Home. Manufactured homes shall meet the standards in Section 18.08.05.E. d. Accessory Structures (detached garages and storage structures). Accessory structures used solely for parking of vehicles or storage may be constructed such that the floor is below the regulatory flood elevation, provided the structure is designed and constructed in accordance with the following requirements: 1. Use of the accessory structure must be limited to parking of vehicles or storage; 2. The portions of the accessory structure located below the regulatory flood elevation must be built using flood resistant materials; 3. The accessory structure must be adequately anchored to prevent flotation, collapse and lateral movement; 4. Any machinery or equipment servicing the accessory structure must be elevated or floodproofed to or above the Regulatory Flood Elevation; 5. The accessory structure must comply with floodway encroachment provisions in Section 18.08.05.G; and 6. The accessory structure must be designed to allow for the automatic entry and exit of flood waters in accordance with Section 18.08.05.A.3.e 1. or 2. Detached garages, storage structures and other accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in Section 18.08.05.A.3.a 1., 2., or 3. as appropriate. Upon completion of the structure, certification by a registered professional engineer or surveyor that the requirements of this section have been satisfied shall be provided to the floodplain administrator for verification. 4. Flood Openings. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. Designs for meeting this requirement must meet or exceed the following criteria: a. For non-engineered openings: 1. Have a minimum of two openings, on different sides of each enclosed area, having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above grade; 3. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they either permit the automatic entry and exit of floodwater, or b. For engineered openings: 1. Engineered openings (or covers and devices) that are specifically designed and certified by a registered engineer or architect as meeting the required performance and design requirements. 2. Engineered openings (or covers and devices) for which an evaluation report has been issued by the International Code Council (ICC) Evaluation Service, Inc. (ICC-ES), a subsidiary of the International Code Council, Inc. 5. Machinery and Service Equipment. All new construction, substantial improvement and other proposed new development shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. B. Standards for Storage of Materials and Equipment. 1. The storage or processing of materials that could be injurious to human, animal or plant life if released due to damage from flooding is prohibited in special flood hazard areas. 2. Storage of other material or equipment may be allowed if not subject to damage by floods and if firmly anchored to prevent flotation, or if readily removable from the area within the time available after flood warning. C. Standards for Water Supply and Waste Disposal Systems. 1. All new or replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from systems into flood waters. 2. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. 3. Waste disposal systems shall not be installed wholly or partially in a regulatory floodway. D. Additional Development Standards for Subdivisions. 1. All new subdivision proposals and other proposed development (including proposals for manufactured home parks and subdivisions), greater than fifty lots or five acres, whichever is the lesser, shall: a. Identify the special flood hazard area and the base flood election; b. Identify on the final plans the elevation(s) of the proposed structure(s) and pads. If the site is filled above the base flood election, the final lowest floor and grade elevations shall be certified by a registered professional engineer or surveyor and provided to the floodplain administrator for verification. c. All subdivision proposals and other proposed development shall be consistent with the need to minimize flood damage. d. All subdivision proposals and other proposed development shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage. e. All subdivision proposals and other proposed development shall provide adequate drainage to reduce exposure to flood hazards. E. Standards for Manufactured Homes. All manufactured homes that are placed on site or substantially improved shall: 1. Be elevated to conform with Section 18.08.05.A.3.a.1., 2., or 3., as appropriate so that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is at or above the regulatory flood elevation; and 2. Be securely anchored to an adequately anchored foundation system to resist flotation, collapse or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state, county and local anchoring requirements for resisting wind forces. Upon completion of installation of the manufactured home, certification by a registered professional engineer or surveyor that the elevation requirements of this section have been satisfied shall be provided to the floodplain administrator for verification. F. Standards for Recreation Vehicles. All recreational vehicles placed on site shall: 1. Be on site for fewer than one hundred and eighty consecutive days; 2. Be fully licensed and ready for highway use. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions; or 3. Meet the permit requirements of Section 18.08.04 of this chapter and the elevation and anchoring requirements for manufactured homes in Section 18.08.05.D. G. Floodways. Located within the special flood hazard areas established in Section 18.08.03.B are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions apply: 1. Prohibit encroachments including fill, new construction, substantial improvements, and other development within the adopted regulatory floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment shall not result in any increase in flood levels during the occurrence of the base flood discharge. 2. If Section 18.08.05.G is satisfied, all new construction and substantial improvements shall also comply with all other applicable flood hazard reduction provisions of Section 18.08.05.

(Ord. No. 739, § 2, 12-19-2023)

Ask a question about Cottonwood law

Corpus searches the Cottonwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.