For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-2-4 — DIGITAL/ELECTRONIC DRAWING FILE SUBMISSIONS

Mesa City Code (Supp. No. 22: codified through Ordinance No. 5996, adopted March 9, 2026) · Mesa City Code § 7-2-4

Corpus is an independent public-information project, not the official City of Mesa website. Stable reference: corpuslaw.us/code/1a00536f-54d6-41d8-ba66-9ab6d1b1da06

7-2-4: - DIGITAL/ELECTRONIC DRAWING FILE SUBMISSIONS

(A) General. Projects requiring a construction permit from Development Services, including projects performed under annual facilities permits, shall be submitted in digital/electronic format. Other than construction permits, drawing shall not be required for the following: 1. R-3, R-4, and R-5 occupancies. 2. Other buildings or structures accessory to and located on the same lot with one- and two-family dwellings. 3. Projects not required to submit drawings to obtain a permit. (Refer to Title 4, Chapter 1, Mesa Administrative Code). The digital/electronic copy of the permit drawings shall be submitted to the Mesa Fire and Medical Department (MFMD) through the Development Services DIMES database for approval by MFMD Technical Services prior to the issuance of the certificate of occupancy/completion by the Development Services Director. (B) Required Format. Submittals shall be digital/electronic files in one of the following formats: (.dwg) or (.dxf). If submitted files are embedded with external references (example: .xref), such drawings shall also be uploaded in DIMES. Cryptic naming of layers/files shall include a "definition key." All digital/electronic files shall be drawn in "feet" at a 1:1 scale. New buildings three stories or more when required by the Fire Code Official shall provide: 3D object-oriented software shall comply with interoperability standards capable of data exchange with coordination and collaboration software. Modeling must represent real axonometric dimensions and accurately define project site with X, Y, Z coordinates. Refer to Fire Details for software and formatting specifics. 1. Required Information. At minimum, each file shall contain the following information: (a) Floor Plans: i. One floor plan with exterior and interior walls for each building floor. ii. All door locations (ingress/egress) throughout the building, including roll up doors and roof hatch/doors. iii. Stairs and elevator locations. iv. Room/suite names and/or numbers. v. Utility shutoff locations (water, electric and gas). vi. Special hazards and high-piled stock/racks, if any. vii. Fire protection items shall include at minimum, standpipes, fire sprinkler risers, alarm panels, fire department connections, and Knox boxes. viii. Building elevations with height dimensions. (b) Site Plan: Including parking lots, building numbers, parking garages, fire lanes, and hydrants. (c) Roof Plan: Layout and access (ladder/hatch locations). 2. Not Required. Layers listing furnishings, floor coverings, ceiling styles/grids, plumbing fixtures, electrical (lights, switches, outlets), wall coverings, or landscape information.

(Ord. No. 5978, § 6, 12-8-25)

Ask a question about Mesa law

Corpus searches the Mesa sections it holds and shows the ones that match, with their citations. Free, no sign-in.