For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 1205 — Frontage Elements

City Code of the City of Phoenix, Arizona (Phoenix City Code current through Ordinance G-7524, passed June 17, 2026 (municipal.codes publication, scraped 2026-11-17)) · Phoenix Zoning Ordinance § 1205

Corpus is an independent public-information project, not the official City of Phoenix website. Stable reference: corpuslaw.us/code/e6837a05-d608-4458-bed4-5c9f581116a4

Section 1205. Frontage Elements.

The following frontage elements consist of architectural features, designs, and amenities which may project within the frontage zone, though no closer than the required minimum setback unless specifically permitted by this chapter. Please see the streetscape and frontage zone matrix for each character area for applicable standards, in addition to the streetscape and frontage zone standards of Section 1204. A. Active Front Yard (AFY). An active front yard is a frontage element intended for use on blocks with a high percentage of existing and/or historic residential structures. AFY is not permitted for use on sites with primary uses which are nonresidential, or on residential lots with more than four primary dwelling units. (R*) 1. For sites with HP zoning or designation, both the building elevations and improvements in the frontage zone shall be constructed as approved by Historic Preservation. 2. For sites not zoned or designated HP, buildings and improvements shall be installed in conformance with Section 507 Tab A II.C.9 (Residential Lot Design Review). If any of the requirements of Section 507 Tab A II.C.9 conflict with provisions of the Downtown Code, Section 507 Tab A II.C.9 requirements shall prevail. 3. Minimum building frontages stated in the streetscape and frontage zone matrix for each character area do not apply when implementing active front yard standards as a frontage element. B. Patio (PA). A patio (previously known as a "dooryard") is a residential frontage element which incorporates a private outdoor space for each dwelling unit, and is surrounded by a fence or wall to provide a separation of the private realm from the adjacent streetscape. [image] 1. A permanent hardscaped or landscaped area shall be provided in accordance with the following standards: a. Minimum depth: eight feet. (R*) b. Minimum area: 64 square feet. (R*) c. Maximum grade differential: 30 inches above adjacent streetscape grade. (T) d. Placement: adjacent to the individual dwelling unit entry. (R*) e. Hardscape shall consist of concrete slab, pavers, open grid pavers, wood decking (if elevated) or equivalent alternative. (T) 2. Pedestrian Access. An opening in the wall/fence, or stairs to the elevated area, shall be provided for a pedestrian connection to the adjacent streetscape from each patio. (R*) 3. Separation of Public and Private Realm. a. A wall/fence of at least 40 inches in height shall be provided around each patio, up to a maximum of 72 inches in height as measured from the adjacent streetscape grade. This maximum height applies only to walls abutting patios and not to other walls located in the frontage zone. b. The portion of walls or fences above 40 inches in height shall consist of view fencing, as approved by Planning and Development. c. Screen walls/fences may be constructed on top of permitted retaining walls, but the combined height of the retaining wall and screen wall/fence may not exceed 72 inches as measured from the adjacent streetscape grade. 4. Shade. Each patio shall have a minimum of 50 percent shade provided either by landscaping or permanent structural shade. (T) C. Stoop/Door Well (SD). A stoop/door well is a type of facade that provides an entryway that is elevated (stoop) or depressed (door well) to provide differentiation from the adjacent streetscape. A stoop/door well is constructed as an integral part of the building, rather than as a courtyard or patio. It may or may not have structural shade. [image] 1. A landing area shall be provided for each stoop/door well in accordance with the following standards: a. Minimum depth: six feet. (R*) b. Minimum area: 36 square feet. (R*) c. Maximum grade differential: 60 inches above or below adjacent streetscape grade. Retaining walls of up to 66 inches in height may be permitted within the frontage zone when necessary for this frontage element. (T) d. Placement: adjacent to a primary entrance. (R*) e. Walls/fences, if provided, shall not exceed 40 inches in height. 2. Pedestrian Access. A pedestrian connection to the adjacent streetscape zone from each stoop/door well shall be provided. (R*) 3. Minimum Building Frontage Requirements. If a stoop/door well is deeper than the applicable frontage zone depth for that street and character area, the width of the stoop/door well shall still count towards the minimum building frontage requirement(s), so long as the front (street side) of the stoop/door well is located within or abutting the frontage zone. (R*) D. Porch (PO). A porch frontage element consists of a covered structure that is often elevated above street grade, sheltering an outdoor area deep enough to ensure usability. A porch is larger than a stoop and is structurally shaded for its entirety. A porch provides a transition between the public and private realm, and creates opportunity for interaction between neighbors. [image] 1. Each porch shall meet the following requirements: a. Minimum depth: eight feet. (R*) b. Minimum area: 96 square feet. (R*) c. Maximum grade differential: 60 inches above the adjacent streetscape grade. (R*) d. Placement: adjacent to a primary entrance. (R*) e. Each porch shall have 100 percent structural shading. (R*) f. Porch floor shall consist concrete, stone, metal, wood decking, or equivalent alternative suitable for outdoor flooring. (T) g. Walls/fences, if provided, shall not exceed 40 inches in height. 2. Pedestrian Access. A pedestrian connection to the adjacent streetscape zone from each porch shall be provided. (R*) 3. Minimum Building Frontage Requirements. If a porch is deeper than the applicable frontage zone depth for that street and character area, the width of the porch shall still count towards the minimum building frontage requirement(s), so long as the front (street side) of the porch is located within or abutting the frontage zone. (R*) E. Common Entry (CE). A common entry is a building facade design element which includes ground floor entrance(s) to a shared lobby/hallway, which in turn provides direct access to residential units and/or office suites on all floors. This frontage element is generally not intended for use with frontages consisting primarily of retail suites. Elevations should include a large number of transparent windows and frequent building entrances to create visual interest from the adjacent public sidewalk, though to a lesser extent than storefront. This frontage element should also include cantilevered canopies or awnings. [image] 1. Primary Entrance Requirements. a. A minimum of one primary entrance leading to a shared lobby/hallway is required from each frontage on a pedestrian street. For sites located at an enhanced corner, the corner building entry may serve as the required primary entrance for both street frontages. (R*) b. Additional primary entrances are required on each pedestrian street frontage at the rate of one per 100 feet of building frontage. Each additional primary entrance (beyond the minimum one per street frontage) may provide access to either a shared lobby/hallway or an individual commercial/office suite. (R*) c. Stoops or door wells may be provided as part of any common entry frontage, even if stoop/door well is not a permitted frontage element per the applicable streetscape and frontage zone matrix, so long as they comply with all stoop/door well development standards. 2. Glazing Requirements. a. Location: the area between three feet and eight feet above the adjacent sidewalk grade. b. Minimum amount: 50 percent of each required building frontage, which may include primary entrances if the doors are glass and meet visibility requirements. (R*) c. Glazing requirements shall be calculated as a percentage of the common entry frontage element length. d. Glazing shall allow a minimum of 75 percent of the visible light (as specified by the manufacturer) to be visible on either side of the window. This includes the doors for any primary entrances located within the common entry frontage element. (R*) 3. Shade Requirements. A cantilevered canopy, fixed awning, or retractable awning shall be provided along each common entry frontage element, in accordance with Section 1204.B.2, and the following: a. Minimum depth: five feet. (R*) b. Minimum length: 50 percent of the common entry frontage element length. c. Minimum clear height: ten feet, if not required greater clearance per Section 1204.B.2. (T) 4. Walls/Fencing. a. Retaining walls may be provided as otherwise permitted by this chapter. A railing/view fence is permitted on top of a retaining wall to a height of 40 inches if required for pedestrian safety due to the grade differential. F. Forecourt (FC). A forecourt is a pedestrian-oriented design element, where a courtyard that is open to the sky and the street (or two streets if located on a corner) is provided. The forecourt may be used as an entry area and shared garden space for residential uses, or as additional shopping, seating, or gathering areas adjacent to and accessible from the street for commercial uses. Art installations and other pedestrian amenities are also appropriate uses within a forecourt. [image] 1. Mechanical equipment, transformers, trash and recycling containers, and vehicular uses are not permitted within a forecourt. 2. Minimum Building Frontage Requirements. If a forecourt is deeper than the applicable frontage zone depth for that street and character area, the width of the forecourt shall still count towards the minimum building frontage requirement(s), so long as compliance with other streetscape and frontage zone requirements (including but not limited to slopes, landscaping, and amenities) is demonstrated. 3. Minimum glazing: 50 percent of the area measured between three and eight feet above grade for the portion of the building facade abutting each forecourt. (R*) 4. A forecourt should be a minimum 500 square feet in size, with a minimum street frontage of 20 feet. (P) Rationale: A forecourt needs to be of a minimum size to encourage gathering, while also having a large enough frontage to encourage pedestrians to enter and create a successful transition between the public and private realm. 5. Accessibility. Forecourts shall have a slope not exceeding two percent, except for approved ADA ramps, and be grade-separated by no more than 24 inches above or below the abutting streetscape zone(s). (T) 6. Pedestrian Access. A minimum of one pedestrian connection to each streetscape zone abutting the forecourt shall be provided. (R*) 7. Primary Entrance Requirements. a. Residential Uses. At least one residential unit shall have a primary entrance from a forecourt, unless a primary entrance is provided which leads to a lobby or hall which provides direct access to the abutting unit(s). (R*) b. Commercial Uses. Each ground floor commercial suite abutting a forecourt shall provide a primary entrance into the forecourt, unless a primary entrance is provided which leads to a lobby or hall which provides direct access to the abutting suite(s). (R*) 8. Walls/Fences/Public Access. A forecourt is a quasi-public area which is an extension of the public realm. No walls or fences are permitted within or abutting a forecourt, except as follows: a. Walls or fences not exceeding 40 inches in height. b. Retaining walls, as otherwise permitted by this chapter. A railing/view fence is permitted on top of a retaining wall to a height of 40 inches if required for pedestrian safety due to the grade differential. c. View fencing (no solid/opaque portions) surrounding areas approved for outdoor dining or outdoor alcohol consumption may be provided up to a height of 72 inches above the forecourt grade. d. Walls/fencing separating private residential patios which front on a forecourt may be provided up to a height of 72 inches above the grade of the forecourt, so long as all portions of the wall/fence above 40 inches consists of view fencing, as approved by Planning and Development. 9. Shade Requirements. A minimum of 50 percent of each forecourt should be shaded with landscape and/or structural shade. (P) Rationale: Shade is needed in the hotter months to encourage users to gather in the area. G. Storefront (S). A storefront is a building facade design element which includes a ground floor elevation with a large number of transparent windows and frequent building entrances to create visual interest from the adjacent public sidewalk. This frontage element is traditionally used for retail, live/work, and other nonresidential active uses and should include cantilevered canopies or awnings. [image] 1. Minimum Building Frontage Requirements. If a portion of the frontage zone occupied by outdoor dining or outdoor liquor service is deeper than the applicable frontage zone depth for that street and character area, the width of the outdoor dining/liquor service area shall still count towards the minimum building frontage requirement(s), so long as compliance with other streetscape and frontage zone requirements (including but not limited to slopes, landscaping, and amenities) is demonstrated. 2. Primary Entrance Requirements. a. Each ground floor commercial suite located within a storefront frontage element shall provide a primary entrance on the street side that directly connects to the street. A suite which abuts a corner may meet this requirement for both street frontages by providing a single primary entrance at the corner. (R*) b. A recessed display entry may be included as part of a storefront frontage element. 3. Glazing Requirements. a. Location: the area between three feet and eight feet above the adjacent sidewalk grade. b. Minimum amount: per the table below. (R*) Number of Primary Entrances* Within Storefront Frontage Element: | Glazing Requirement: Number of Primary Entrances* Within Storefront Frontage Element: | Glazing Requirement: One: | 75% Two: | 70% Three: | 65% Four or more: | 60% c. Glazing requirements shall be calculated as a percentage of the storefront frontage element length. 4. Shade Requirements. A cantilevered canopy, fixed awning, or retractable awning shall be provided along each storefront frontage element, in accordance with Section 1204.B.2, and the following: a. Minimum depth: five feet. (R*) b. Minimum length: 75 percent of the storefront frontage element length. (R*) c. Minimum clear height: ten feet, if not required greater clearance per Section 1204.B.2. (T) 5. No fencing is permitted within the streetscape or frontage zones adjacent to a storefront frontage element, except as follows: a. Retaining walls may be provided as otherwise permitted by this chapter. A railing/view fence is permitted on top of a retaining wall to a height of 40 inches if required for pedestrian safety due to the grade differential. (R*) H. Gallery/Arcade (GA). A gallery or an arcade is a building facade design element where significant and continuous structural shade is provided for pedestrians, often over the actual public sidewalk. Similar to the storefront frontage element, a large number of transparent windows and frequent building entrances should be provided to create visual interest from the adjacent public sidewalk. This frontage element is traditionally used for retail, office, and other nonresidential active uses. [image] Gallery [image] Arcade 1. Minimum Setback Requirements. A gallery/arcade may project into the frontage zone to the property line and is not required to meet minimum setbacks as stated in the applicable character area so long as compliance with other streetscape and frontage zone requirements (including but not limited to slopes, landscaping, and amenities) is demonstrated. (R*) 2. Minimum Dimensions. All portions of a gallery/arcade frontage element shall comply with the following: a. Minimum depth: ten feet. (R*) b. Maximum depth: 30 feet. No maximum for the portion of a gallery/arcade is being used for outdoor dining, outdoor liquor service, or a public gathering space. (R*) c. Minimum spacing between columns/supports: ten feet as measured parallel to the street. (R*) d. Minimum clear height: ten feet as measured from finished grade. (R*) e. Maximum clear height: 25 feet as measured from finished grade. (R*) 3. Pedestrian Use. All portions of a gallery/arcade frontage element shall have a walkway provided for pedestrians. The walkway may serve as the actual public sidewalk, if public easements are dedicated, or it may be provided in addition to the public sidewalk located within the streetscape zone so long as the area under the gallery/arcade is also open for pedestrian use. a. Public sidewalk easement dedications shall be no less than the required sidewalk width for the applicable character area. (T) b. Outdoor uses (dining, alcohol consumption, or similar), if permitted by the character area, may be provided within a gallery/arcade, so long as the greater of five feet, or the minimum public sidewalk width (if there is no other public sidewalk) is left unobstructed for use as a pedestrian walkway. (R*) 4. Primary Entrance Requirements. a. Each gallery/arcade frontage element shall provide a minimum of one primary entrance on the street side that directly connects to the street. A single primary entrance provided at the corner of a building at a street intersection complies this requirement for both street frontages. (R*) b. A recessed display entry may be included as part of a gallery/arcade frontage element. 5. Glazing Requirements. a. Location: The area between three feet and eight feet above the adjacent sidewalk grade for the portion of the building that is a gallery/arcade frontage element. (R*) b. Minimum amount: per the table below. (R*) Number of Primary Entrances* Within Gallery/Arcade Frontage Element: | Glazing Requirement: Number of Primary Entrances* Within Gallery/Arcade Frontage Element: | Glazing Requirement: One: | 75% Two: | 70% Three: | 65% Four or more: | 60% c. Glazing requirements shall be calculated as a percentage of the gallery/arcade frontage element length. 6. Walls/Fencing. a. No walls or fences are permitted in the frontage zone adjacent to a gallery/arcade frontage element which separates the gallery/arcade from the frontage zone. b. Walls and fences within a gallery/arcade may be provided to separate outdoor dining or other permitted outdoor uses from the public walkway, if compliance with both of the following is demonstrated: (1) A minimum five-foot walkway clearance (or the minimum sidewalk width, if the public sidewalk has been located within the gallery/arcade) is maintained. (2) View fencing (no solid/opaque portions) may be provided up to a height of 72 inches above the gallery/arcade grade. I. Recessed Display Entry. A recessed display entry is not a separate frontage element; rather it is a feature which may be included as part of a common entry, storefront or gallery/arcade frontage element. The characteristics of a recessed display entry are as follows: [image] 1. Consists of a primary entrance to a public space (retail, restaurant, lobby/reception, etc.) recessed from the facade of the building, and is shaded by the upper portion of the building. 2. Minimum depth to primary entrance: five feet. (R*). 3. Maximum depth to primary entrance: 25 feet. (R*) 4. Minimum clear height: eight feet on private property; ten feet if permitted to project within public ROW or into a public sidewalk easement. (T) 5. Glazing provided within the recessed display entry counts toward the minimum required glazing for the associated frontage element. 6. Shade provided by a recessed display entry counts towards the minimum requirement for the associated frontage element. 7. No portion of a recessed display entry may be fenced off, unless included as a part of an outdoor dining/bar/patio which is otherwise allowed. 8. If a recessed display entry is deeper than the applicable frontage zone depth for that street and character area, the width of the recessed display entry shall still count towards the minimum building frontage requirement(s), so long as compliance with other streetscape and frontage zone requirements (including but not limited to slopes, landscaping, and amenities) is demonstrated. J. Grand Entry (GR). [image] A grand entry is a building facade design element which includes the most important pedestrian entrance to the building, indicated by significant architectural features and windows which may be provided more for visual impact than actual need. A grand entry should also incorporate significant public gathering space(s), pedestrian amenities, and art. A grand entry may also incorporate vehicular passenger loading and valet functions, including a porte-cochere, if the proposed use allows it. A grand entry would typically be used in conjunction with hotels, government buildings, educational institutions, hospitals, large office buildings, large residential and mixed-use buildings, and large assembly uses. [image] 1. Applicability. A grand entry frontage element may be provided for the following uses if also permitted by the streetscape and frontage zone matrix for the applicable character area: (R*) a. Hotels. b. Government buildings. c. Schools/educational institutions. d. Hospitals. e. Office, retail, assembly, and mixed use buildings 100,000 square feet (gross) or larger. f. Residential buildings with at least 100,000 square feet (gross) or 100 dwelling units. 2. Main Entrance. A grand entry frontage element must serve as the main and most prominent entrance to the building for pedestrians. At least one primary entrance shall be provided which leads to a lobby or other internal gathering area which provides access to any ground-level suites and upper stories. (R*) 3. Architecture. A grand entry should consist of architectural features which are prominent and intended to attract users to the main entry. These features may extend above the height of the frontage zone. Examples are: porticos/columns, large sets of steps; significant structural shade; extensive and imaginative use of colors, textures, windows, and/or lighting; prominent exterior works of art; and monuments. Signage may also contribute if otherwise in compliance with applicable sign regulations. (R*) 4. Pedestrian Accessibility. Pedestrian access to the primary entrance must be visually obvious, preferably by use of materials and colors. The access route should be greater in width than any minimum required for ADA accessibility and commensurate in scale with the architectural features of the grand entry. Pedestrian routes may cross vehicular areas but must otherwise be segregated from vehicular traffic. (R*) 5. Passenger Loading. A passenger loading zone, including a porte-cochere, may be part of a grand entry and located within the frontage zone if it complies with all of the following: (R*) a. It does not preclude installation of required streetscape and frontage zone improvements, including trees; and b. It allows for the most intuitive and direct pedestrian access to the primary entrance from the streetscape zone. 6. Valet Parking. A valet parking station and valet parking zone, including a porte-cochere, may be incorporated within a grand entry if it complies with all of the following: (R*) a. It is a permitted accessory use per the Land Use Matrix; b. It is constructed in accordance with Section 1206.G. c. It does not preclude installation of required streetscape and frontage zone improvements, including trees; and d. It allows for the most intuitive and direct pedestrian access to the primary entrance from the streetscape zone. 7. Trash and recycling containers, service areas, and commercial loading areas are not permitted to be incorporated within a grand entry, or within the adjacent streetscape or frontage zones. Mechanical equipment and transformers/utility equipment may be provided only if located within a building or subterranean ground vault. (R*) 8. Minimum Building Frontage Requirements. If a grand entry incorporates pedestrian plazas, outdoor dining, outdoor liquor service, or other improved public gathering areas which are deeper than the applicable frontage zone depth for that street and character area, the width of the gathering areas shall still count towards the minimum building frontage requirement(s), so long as compliance with other streetscape and frontage zone requirements (including but not limited to slopes, landscaping, and amenities) is demonstrated. (R*)

Ask a question about Phoenix law

Corpus searches the Phoenix sections it holds and shows the ones that match, with their citations. Free, no sign-in.