§ 106-5.4 — Mixed use resort (MU-3)
Municipal Code of Surprise, Arizona (Supp. No. 68: codified through Ordinance No. 2026-07, adopted January 20, 2026) · Surprise Municipal Code § 106-5.4
Corpus is an independent public-information project, not the official City of Surprise website. Stable reference: corpuslaw.us/code/c5fc7d5e-7854-4e30-86ad-956d11bc0f5d
Sec. 106-5.4. - Mixed use resort (MU-3).
A. Purpose. The mixed use resort (MU-3) zoning district provides for the development of resort areas into the natural environment and setting with ancillary recreational amenities as well as residential cluster development. This zoning district also allows limited commercial establishments that specifically cater to the needs of the tourist oriented trade and which are designed and located to be walkable from the resort area without interference to other daily functions of the surrounding community and other uses in the vicinity. B. Applicability and density. 1. The MU-3 zoning district may be applicable for land that is: a. Within the scenic lands development sub area of the neighborhood character area, of the city General Plan; as a rural development type. b. Within the commerce and office character area of the city General Plan; as a mixed use residential development type. 2. The minimum development parcel size to request MU-3 zoning is twenty (20) acres. The allowed overall gross residential density of a MU-3 development is between eight (8) and twenty (20) dwelling units per acre when the resort development includes an ancillary residential component. C. Review and process. 1. Procedures. a. A resort master site plan (MSP) shall be submitted as part of the rezoning process pursuant to Chapter 102 of this ordinance. The resort MSP is the compilation of exhibits that demonstrate compliance with all requirements of this ordinance and shall identify the size and location of each allowed development parcel listed below. (1) Residential. A residential development parcel does not require space designed for commercial occupancy but is meant for a variety of housing. (2) Non-residential. A non-residential development parcel has no residential requirement associated with the land uses permitted in Table 106-1c. (3) Mixed use. A mixed use development parcel incorporates multi-family housing with space designed for commercial occupancy. The ground floor of all mixed use structures shall be designed for commercial occupancy; except residential structures in a horizontal mixed use site plan. b. Development parcels labeled as residential will be platted as per Chapter 108 of this ordinance and shall comply with the PEDS and other design standards in Chapter 107 . c. A site plan review will still be required for any multiple-building apartment complex, mixed use, or non-residential development. 2. Amendments. A council approved resort MSP may be amended administratively for the following circumstances: a. Up to a ten (10) percent transfer (increase or decrease) in the allowed quantity of dwelling units between development parcels with the resort MSP; b. Up to a ten (10) percent increase or decrease to the gross residential density of the resort MSP as compared to city council approval; c. Up to a ten (10) percent shift in the individual development parcel gross area or configuration, as compared to city council approval. 3. Requests for an administrative amendment shall require the following: a. The master developer, or the specific applicant if the master developer is no longer involved in the project, shall provide the city with a "revised resort MSP" that reflects any and all administratively approved alterations to date. b. No further applications for plats, site plans, or building permits shall be submitted to the city until after the administrative amendment request has been determined; and if approved, a new "revised resort MSP" showing the latest approved amendment has been submitted back to the city. 4. Administrative amendment to the resort MSP shall not be allowed if: a. Any amendment would require backbone infrastructure (water and wastewater) upsizing, or change the parameters for the master drainage design, or change the amount or intent of the open space component of the resort MSP as compared to the initial approval. 5. Any alteration to the "resort MSP" that exceeds the limits set for administrative approval, as listed above, shall require city council action as a resort MSP amendment. D. Development standards. 1. The resort MSP will comply with overall development standards shown in Table 106-5c related to the perimeter to the overall development. 2. Each development parcel shall further comply with the development standards identified in Table 106-5d and Table 106-5e related to the internal development within the overall resort MSP. 3. Each residential lot of record will be allowed a maximum of three (3) dwelling units, provided that said lot has a minimum lot area of three thousand five hundred (3,500) square feet per dwelling unit. 4. The individual building footprint for a mixed use or non-residential land use shall be limited to a maximum of thirty thousand (30,000) square feet; excluding the main resort structure and ancillary restaurant. 5. Within the thirty thousand (30,000) square feet building footprint limits, non-residential uses shall be further limited to fifteen thousand (15,000) square feet per tenant. Table 106-5c—Mixed Use Resort (MU-3) Zoning Overall Project Development Standards Min. resort MSP project size | 20 acres Gross residential density (du/ac) | 8—20 Min. setback to arterial ROW | 35 Min. setback to collector and local ROW (ft) | 20 Min. setback adjacent to residential zoning (ft) | 45 Min. setback adjacent to non-residential zoning (ft) | 30 Net open space (%) | 30% Table 106-5d—Mixed Use Resort (MU-3) Zoning Residential Development Standards Lot Categories | A1 | B1 | C1 Lot area (sf) | 4,000—7,999 | 8,000—15,999 | 16,000—20,000 Min. lot width (sf) | 40 6 | 60 | 80 Min. front setback (ft) | 12 2, 3 | 15 2, 3 | 15 2, 3 Max. front setback (ft) | 30 4 | 30 4 | 30 4 Min. side setback (ft) | 5/10 total 2, 5 | 5/10 total 2, 5 | 10 Min. rear setback (ft) | 12 2 | 12 2 | 20 2 Max. bldg. height (ft) | 30 | 30 | 30 Lot coverage % | 50 | 40 | 30 Notes: 1. Maximum of three (3) dwelling units per lot of record, provided that said lot has a minimum lot area of three thousand five hundred (3,500) square feet per dwelling unit. 2. Garage doors/embellishments shall be setback a minimum of twenty [20] feet measured from the opposing property line, except rear, alley loaded garages, which shall be setback six (6) feet from the alley edge line. 3. A covered front porch may encroach closer to the street by up to five (5) feet. 4. Measured from the primary dwelling, excluding front porch. 5. Minimum side setback: one (1) side / total side setbacks on a lot. May be reduced to zero-foot setback for single-family dwellings as attached building to and separated by a common wall along the property line. End units shall maintain the total combined setback. 6. Residential projects shall contain no more than fifty (50) percent of lots less than forty-eight (48) feet wide as calculated across whole subdivisions or preliminary plat and will include mitigating designs outline in Chapter 108 of this ordinance. Table 106-5e—Mixed Use Resort (MU-3) Zoning Non-Residential and Mixed Use Development Standards Non-Residential | Mixed Use Min. lot area (sf) | 20,000 (min.) | 20,000 Lot area per dwelling unit (sf/du) | N/A | 2,100—5,400 Min. setback to arterial ROW | 15 | 20 Min. setback to collector and local ROW (ft) | 30 | 15 1 Min. setback adjacent to residential parcels (ft) | 10 | 10 Min. setback adjacent to non-residential zoning (ft) | 12 | 20 Max. bldg. height (ft) | 45 2 | 50 2 Notes: 1. Setback may be reduced to ten (10) feet along collector or local ROW for units that open to the street and exclude a perimeter wall. 2. The height of any structure, or portions thereof, shall not exceed 30 feet in height measured at the setback line when adjacent to RR, R-1, and R-2 zoning districts and established uses. The height of the accessory structure may increase at a ratio of one-foot vertical for every one-foot horizontal as measured relative to the property line to a maximum height equal to the zoning district.
(Ord. No. 2024-03, § 1(Exh. A), 3-5-24)
Ask a question about Surprise law
Corpus searches the Surprise sections it holds and shows the ones that match, with their citations. Free, no sign-in.
