Sec. 12-29. - Standards of construction.
In all Special Flood Hazard Areas the following standards are required: (1) Anchoring: a. All new construction and substantial improvements shall be anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; and b. All manufactured homes shall meet the anchoring standards of Section 12-33(a). (2) Construction materials and methods: a. All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage; b. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage; c. All new construction, substantial improvement, and other proposed new development shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located to or above the regulatory flood elevation to prevent water from entering or accumulating within the components during conditions of flooding; and d. Within zones AH or AO, adequate drainage paths shall be constructed around structures on slopes to guide floodwaters around and away from proposed structures. (3) Elevation and floodproofing: a. Residential construction. Residential construction, new or substantial improvement, shall have the lowest floor, including basement, elevated to or above the regulatory flood elevation; i. In an AO zone, elevated to or above the regulatory flood elevation, or elevated at least two (2) feet above the highest adjacent grade if no depth number is specified; ii. In an A zone where a base flood elevation data has not been provided, the Floodplain Administrator shall obtain, review, and reasonably utilize any base flood elevation data available from a federal, state, or other source, in order to administer Section 12-29. Any such information shall be consistent with the requirements of the FEMA and the Director of the Arizona Department of Water Resources and the lowest floor shall be elevated to or above the regulatory flood elevation; or iii. In zones AE, and AH, base flood elevation is determined from the FIS and/or FIRM. Upon completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by Tempe's building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. b. Nonresidential construction. Nonresidential construction, new or substantial improvement, shall either be elevated to conform with paragraph (3)(a) of this section or together with attendant utility and sanitary facilities: i. Be floodproofed below the elevation recommended under subsection (3)(a) of this section so that the structure is watertight with walls substantially impermeable to the passage of water; ii. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. Upon completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by Tempe's building inspector to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. c. Flood openings. All new construction and substantial improvement with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must meet or exceed the following criteria: i. Have a minimum of two (2) openings, on different sides of each enclosed area, having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding. The bottom of all openings shall be no higher than one (1) foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwater; or ii. Have engineered openings (or covers and devices): 1. That are specifically designed and certified by a registered engineer or architect as meeting the required performance and design requirements; or 2. For which an evaluation report has been issued by the International Code Council (ICC) Evaluation Service, Inc. (ICC-ES), a subsidiary of the International Code Council, Inc. Upon completion of the structure, certification by a registered professional engineer or surveyor that the requirements of this section have been satisfied shall be provided to the Floodplain Administrator for verification. d. Manufactured homes. Manufactured homes shall also meet the standards in Section 12-33(a). e. Attached garages and low cost accessory structures. i. A garage attached to a residential structure, constructed with the garage floor slab below the regulatory flood elevation, must be designed to allow for the automatic entry of flood waters. See paragraph (3)(c) of this section. Areas of the garage below the regulatory flood elevation must be constructed with flood resistant materials. See paragraph (2) of this section; and f. Detached garages and accessory structures. "Accessory structure" used solely for parking (two (2) car detached garages or smaller) or limited storage (small, low-cost sheds), may be constructed such that its floor is below the regulatory flood elevation, provided the structure is designed and constructed in accordance with the following requirements: i. Use of the accessory structure must be limited to parking or limited storage; ii. The portions of the accessory structure located below the regulatory flood elevation must be built using flood-resistant materials; iii. The accessory structure must be adequately anchored to prevent flotation, collapse and lateral movement; iv. Any machinery or equipment servicing the accessory structure must be elevated or floodproofed to or above the Regulatory Flood Elevation; v. The accessory structure must comply with floodway encroachment provisions in Section 12-34; vi. The accessory structure must be designed to allow for the automatic entry of flood waters in accordance with paragraph 12-29(3)(c) of this section; and vii. Detached garages and accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in this section. Upon completion of the structure, certification by a registered professional engineer or surveyor that the requirements of this section have been satisfied shall be provided to the Floodplain Administrator for verification.
(Ord. No. 87.25, 9-10-87; Ord. No. 2005.67, 9-29-05; Ord. No. 2013.52, 10-3-13; Ord. No. O2016.33, § 1, 6-9-2016; Ord. No. O2022.47, § 1, 11-3-22; Ord. No. O2025.33, § 1, 9-18-25)
Ask a question about Tempe law
Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.