§ 4-706 — Screens, Walls and Access Control Landscapes
The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe Zoning and Development Code § 4-706
Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/f3861875-8a3d-4ffb-8389-1141ed2faac6
Section 4-706 - Screens, Walls and Access Control Landscapes.
The following standards are intended to avoid or reduce impacts regarding visual, sound, privacy, and/or glare to and from land uses, and to implement the crime prevention and security standards contained in this chapter. In all locations where walls are either required by this Code, or desired by the owner of the property, the walls shall conform to all provisions of this chapter. A. General Fence and Wall Height Standards. 1. The maximum height of any freestanding wall or fence shall be measured from the highest adjacent finished surface of the ground, paving, or sidewalk within twenty (20) feet, unless otherwise noted; 2. Walls or fences in a required front yard building setback, including walls for single-family dwellings, shall be four (4) feet maximum in height. An increase in the maximum four (4) foot height may be permitted subject to a use permit. With a use permit, the maximum height may be up to six (6) feet, except that an additional two (2) feet of height may be permitted for architectural features including but not limited to archways, pergolas, and other similar features. For all heights above four (4) feet, the use permit shall demonstrate that a natural surveillance to the street will be maintained by incorporating openings, providing transparent materials, or varying height/materials; 3. In areas behind a required front yard building setback and within the required rear and side yards, the maximum height of walls shall be ten (10) feet, except where a taller wall is necessary to screen service areas under Section 4-706(G). For single-family uses, the maximum height shall be eight (8) feet; 4. The Clear Vision Requirements, Section 4-702(G), shall apply to fences and walls; and 5. All fences and walls shall be subject to City review and approval through development plan review, or by approval of the Community Development Director, or designee. Any fence or wall height in excess of seven (7) feet or as determined by Building Code, shall require a building permit. B. Reverse Frontage Walls. An eight (8) foot masonry wall shall be required along the rear of reverse frontage lots, including single-family. C. Wall Design. All required walls shall be located and designed based on the intended screening function, proposed use and adjoining uses, as follows: 1. Walls placed between a residential district and any commercial use, industrial uses, or surface parking lot shall be constructed of masonry or concrete, or equal or better quality material, as approved through development plan review. Alternatively, an ornamental iron fence, combination iron fence with masonry pillars, or similar design with equal or better quality material may be approved. 2. All masonry walls shall have an architectural texture, color and material compatible with the primary building on-site (or on respective sides). Walls may have ornamental decorative iron fence panels, vertical pickets with spacing that is consistent with the Building Code, as an integral part of the design of the wall; 3. A living wall or see-through ornamental iron fence may be approved as a substitute for masonry if the wall is not required for visual screening of mechanical equipment, outdoor storage areas, or parking areas. See Landscape Design Guidelines in Appendix A-IV. D. Land Use Buffers. Property lines of parcels developed for multi-family, mixed-use, commercial, office, or industrial uses that are adjacent to or separated by an alley from any single-family residential district (except when land is used for City parks) or use shall provide a wall and landscape screen in conformance with the following standards: 1. Screen planting areas shall be at least six (6) feet clear in width; 2. Screening shall conform to the Landscape Design Guidelines in the Appendix A-IV; 3. These buffer areas shall contain trees with a maximum spacing of twenty (20) feet on center; 4. All walls shall be constructed of masonry or concrete material and shall be a minimum of eight (8) feet in height; 5. Screens and walls shall provide for natural surveillance, when required by the Community Development Director or designee; and 6. Where a commercial, office or industrial development of over fifty thousand (50,000) square feet of building area is located adjacent to a single-family residential district or use, the landscape buffer described above in this section shall be a minimum of twenty (20) feet wide adjacent to that use. This buffer shall be planted with two (2) rows of trees along the interior side of the required wall. Each row is to contain trees spaced at thirty (30) feet on center and staggered by fifteen (15) feet to the adjacent row, except where an alternative design approved through development plan review would provide an equal or better effect in screening the two (2) uses. See Figure 4-706D. Figure 4-706D. Land Use Buffer [image omitted; see the official code] E. Parking Screens. All on-site parking areas adjacent to streets shall be screened from street view. This standard can be met through the use of the following screening methods, which may be used individually or in combination: 1. A parking screen wall shall be installed adjacent to the edge of the parking. The top of the parking screen wall shall be a minimum of three (3) feet above the adjacent parking surface. Parking screen walls shall be constructed of masonry or concrete, be a minimum of eight (8) inches in thickness, and incorporate offsets and relief. Open areas or portals for natural surveillance shall be provided, if required by the Community Development Director or designee; or 2. Earth berms, if used in lieu of or in conjunction with screen walls, shall have a maximum slope of 4:1 and minimum width of twenty-five (25) feet. Berms are allowed only when there is sufficient area to create a three (3) feet tall berm. See Figure 4-706E. Figure 4-706E. Parking Lot Screens [image omitted; see the official code] F. Outdoor Storage Areas. All outdoor storage areas for materials, vehicles, trailers, equipment, trash or other similar items shall be enclosed by a masonry or concrete wall with gate to screen the view of these uses from public rights-of-way and adjoining residential, commercial and mixed-use districts. This wall, and gate, shall be a minimum of eight (8) feet tall but not to exceed ten (10) feet tall, measured from the highest adjacent grade within twenty (20) feet or street curb, whichever is higher. G. Service Areas. All service bays, loading, delivery and refuse areas shall be screened from street view by a minimum of a six (6) foot high masonry wall. Site conditions and surrounding uses will be used to determine maximum height of walls adjacent to loading areas, service bays, mechanical equipment, etc. that are required to be screened. H. Alleys. Screening requirements along alleys shall be the same as for land use buffers, See Section 4-706(D), except when alley access is allowed by use permit per Section 4-502(F)(2). I. Mobile Home Parks, Mobile Home Subdivisions and Trailer Parks. Perimeter boundaries of all mobile home parks, mobile home subdivisions and trailer parks shall contain a screening and security wall that conforms to the standards in Section 3-416(B), Mobile Homes Perimeter Walls.
(Ord. No. 2005.48, 8-18-2005; Ord. No. 2008.28, 10-2-2008; Ord. No. O2121.44, 10-14-2021)
Ask a question about Tempe law
Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.
