§ 4-803 — Lighting Standards

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe Zoning and Development Code § 4-803

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/e3abc2fd-b2b5-4258-bd8c-2910cecba1d6

Section 4-803 - Lighting Standards.

Prior to issuance of a building, electrical or sign permit, the Community Development Director, or designee, shall determine that the submitted plans and details for said permit are in conformance with the following standards. The stamping of the plans and the signature of the Community Development Director, or designated representative, and the date of the signature shall indicate that the plans are in conformance. Should the applicant desire to substitute outdoor light fixtures or lamps to be installed on private property after a permit has been issued, the applicant shall submit all changes to the Community Development Director or designated representative for approval, with adequate information to assure compliance with this chapter. A. Illumination in General. Exterior lighting shall provide for appropriate and desirable nighttime illumination for all uses on and related to the site, including, but not limited to, pedestrian pathways, plazas, courtyards, building entrances, parking and driveway areas, automatic teller machines (ATMs), and other outdoor spaces commonly used at night. Lighting of exterior areas shall reduce conflicts between building design and landscape treatments, provide appropriate surveillance for crime prevention, and minimize glare or intrusive light onto adjoining properties and into the night sky. B. Illumination LevelsThe maximum illumination level for on-site lighting is forty (40) foot-candles as measured at surface based on light loss factor of sixty-eight percent (0.68) for metal halide lighting and seventy-two percent (0.72) for high pressure sodium lighting. Refer to Section 4-805 Exemptions. C. Mounting and Operation of Light Fixtures. The mounting and operation of light fixtures shall be governed by the following: 1. Building mounted light fixtures shall be attached only to walls and the top of the fixture shall not be higher than necessary to illuminate the area required; 2. In any residential zoning district or within fifty (50) feet of any residential zoning district, freestanding light fixtures shall not exceed eighteen (18) feet in height. Within the next fifty (50) to one hundred fifty (150) feet of any residential zoning district, freestanding light fixtures shall not exceed twenty-five (25) feet in height. In all other locations, freestanding light fixtures shall not exceed thirty (30) feet tall; 3. To comply with 1 and 2, above, height shall be measured from the top of a light fixture to the adjacent surface at the base of the support for that light fixture; 4. Controls for lights for rest rooms identified for general public use shall be of the style that cannot be turned off or on by users other than employees of the business; 5. Light fixture design: a. All luminaries used for security shall be vandal resistant that resist tampering, incorporate vandal resistant refractors (lens) and be provided with a gasket or seal that is designed to resist rain, dust and insect contamination; b. Outdoor light fixtures, which are full cutoff to direct all light below a horizontal plane through the bottom of the fixture and have no lens which drops below the fixture may use any illumination source, up to a maximum of forty (40) foot-candles, as provided in Section 4-803(B); c. Outdoor light fixtures, which have a lens or diffuser which is visible above the horizontal plane and constructed of white/opal glass, are considered non-cutoff and filtered and shall be limited to the light output no greater than one thousand seven hundred (1,700) lumens; d. Outdoor light fixtures, which have a lens or diffuser which is visible above the horizontal plane and constructed of clear or prismatic glass, are considered non-cutoff and non-filtered and shall be limited to the light output no greater than six hundred (600) lumens; Figure 4-803C. Types of Light Fixtures [image omitted; see the official code] e. All conduit shall be concealed; f. The foot-candle level at the property line adjacent to a single-family district (from the proposed lighting) shall not exceed one-half (0.5) foot-candle. Lighting next to a residential use shall not spill over onto that use; g. Lighting fixtures used to illuminate an outdoor advertising sign (billboard) shall be mounted on the top of the sign structure and shall comply with the shielding requirements of this chapter; 6. Ornamental twinkling lights are permitted when part of a window display, patio, landscape or other integral part of a business, provided that they do not exceed one-half (0.5) foot-candles at the property line and do not conflict with the provisions of Section 4-803(C)(5) above, related to adjacent residential use; and 7. Other conditions related to lighting may be required through development plan review. D. Specific Areas to be Illuminated. The following areas on a building or development shall be illuminated to the minimum security lighting levels shown on Table 4-803 D. 1. Secondary lighting may be required to supplement the primary security lighting due to design elements and landscape conflicts, in order to meet the minimum lighting criteria. Table 4-803 D. Specific Areas to be Illuminated Location | Duration | Illumination Level * | Additional Requirements Breezeway Lighting | Dusk to Dawn | 4 Fc | Transitional Lighting Is Required At All Entry areas Building: Entrances and Exits, ATMs | Dusk to Dawn | 5 FC | 2 FC within 15' of the Centerpoint of the Entrance Canopies: Carport Parking Structures, Ramadas, Pavillions, Shade Canopies | Dusk to Dawn | 3 FC | Including Adjacent Landscape Area at Finished Surface. Cluster or Gang Mailboxes | Dusk to Dawn | 4 FC | within a 15' Radius of the Mailboxes Drive Aisles | Dusk to Dawn | 1 FC Gates: Pedestrian, Vehicular | Dusk to Dawn | 4 FC | 2 FC within 15' of the Centerpoint of the Gate Loading Areas and Docks | Dusk to Dawn | 4 FC Parking Lot Drive Aisles | Dusk to Dawn | 1 FC Parking Spaces for Vehicles and Bicycles, Parking Deck (Open) | Dusk to Dawn | 2 FC Parking Structure Entrances/Transition Areas | 24 Hrs | 5 FC Parking Structures and Garages | Dusk to Dawn | 4 FC | Can have dimmers with motion sensors to allow reduction to 2 foot candles when inactive 100% when active Parking Structures and Garages | Dawn to Dusk | 10 FC | Can have dimmers with motion sensors to allow reduction to 2 foot candles when inactive 100% when active Parking Structures and Garages that are Sub-Level | 24 Hrs | 4 FC | Transitional Lighting is Required at all Entry Areas Pedestrian Paths and Adjacent Landscape Areas within 20' of Path | Dusk to Dawn | 0.5 FC Playground Equipment | Dusk to Dawn | 5 FC Refuse Enclosure Area | Dusk to Dawn | 2 FC | 5 FC at Gate to Enclosure Retention Areas and Commercial Patios | Dusk to Dawn | 0.5 FC Stairwells, Landings and Under Areas of Lower Landings | 5 FC | Shall be Continuously Illuminated to this Level * Illumination Level is Measured at Finished Surface. FC = Foot Candles

(Ord. No. 2005.48, 8-18-2005; Ord. No. O2121.44, 10-14-2021; Ord. No. O2026.23, 6-4-2026)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.