For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-300 — Adopted; where filed; amendments

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 8-300

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/b646de80-fed4-4a01-919d-f8262d15578a

Sec. 8-300. - Adopted; where filed; amendments.

That certain document known as "The International Residential Code, 2024 Edition," which has been published as a code in book form by the International Code Council (ICC), chapters one through forty-four, and appendix chapters BB, BF, BG, BO, CA, CB, CD, CE, CF, and NB inclusive, three (3) copies with amendments of which are on file in the office of the City Clerk, and this same code, appendices and amendments are hereby referred to, adopted and made a part hereof, as if fully set forth in this article. Chapter 1 Scope and Administration Notes: 3. For reserved sections herein, refer to the City of Tempe Administrative Code for these code requirements. 4. Any conflicts between this code and the Tempe Administrative Code, the Tempe Administrative Code shall apply. 101.1 Title. These regulations shall be known as the International Residential Code, hereinafter referred to as "this code." These regulations are one document of the overall City of Tempe Construction Code as defined by the adopting ordinance. 101.2 Scope. - Reserved 101.3 Purpose. - Reserved 102 Applicability. - Reserved Section 103 (IRC) Code Compliance Agency - Reserved. Section 104 (IRC) Duties and powers of the Building Official - Reserved. Section 105 (IRC) Permits - Reserved. Section 106 (IRC) Construction documents - Reserved. Section 107 (IRC) Temporary Structures and Uses - Reserved. Section 108 (IRC) Fees - Reserved. Section 110 (IRC) Certificate of Occupancy - Reserved. Section 111 (IRC) Service Utilities - Reserved. Section 112 (IRC) Means of Appeals - Reserved. Section 113 (IRC) Violations - Reserved. Section 114 (IRC) Stop Work Order - Reserved. Section R109.1.1.1. R109.1.1.1 Stem Wall Inspection. Shall be made after any reinforcement is in place and forms (if needed) are in place. Cast in place hardware shall be in place at time of inspection. Section R109.1.1.2. R109.1.1.2 Concrete pre-slab and under-floor inspection. Concrete slab and under-floor inspections shall be made after in-slab or under-floor reinforcing steel and building service equipment, conduit, piping accessories and other ancillary equipment items are in place, but before any concrete is placed or floor sheathing installed, including the subfloor. Section R109.1.7.1. R109.1.7.1 Strap and Shear. All bracing, hardware, and holddowns are in place. Roof sheathing is in place and fastened, all structural sheathing is in place and properly fastened. Approved truss layout and calculations shall be onsite at time of inspection. Section R109.1.8.1. R109.1.8.1 Lath and gypsum panel product inspection. Lath and gypsum panel product inspections shall be made after lathing and gypsum panel products, interior and exterior, are in place, but before any plastering is applied or gypsum panel product joints and fasteners are taped and finished. Section R301.2 TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load o | Wind Design | Seismic Design Category f | Subject To Damage From | Ice Barrier Underlayment Required h | Flood Hazards g | Air Freezing Index i | Mean Annual Temp j Speed d (mph) | Topographic effects k | Special wind region l | Windborne debris zone m | Weathering a | Frost line depth b | Termite c 0 | 115 | NO | NO | NO | B | Negligible | 0 | HEAVY | NO | See Maricopa County | NA | 71.2F MANUAL J DESIGN CRITERIA n Elevation | Altitude correction factor e | Coincident wet bulb | Indoor winter design relative humidity | Indoor winter design dry-bulb temperature | Outdoor winter design dry-bulb temperature | Heating temperature difference - | - | - | - | - | - | - Latitude | Daily range | Summer design gains | Indoor summer design relative humidity | Indoor summer design dry-bulb temperature | Outdoor summer design dry-bulb temperature | Cooling temperature difference - | - | - | - | - | - | - For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(1). The grade of masonry units shall be determined from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM C145, ASTM C216 or ASTM C652. b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the ultimate design wind speeds map [Figure R301.2(2)]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The jurisdiction shall fill in this section of the table to establish the design criteria using "Phoenix Sky Harbor" in Table 10A from ACCA Manual J or established criteria determined by the jurisdiction. f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with: the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas); and the title and date of the currently effective Flood Insurance Study or other flood hazard study and maps adopted by the authority having jurisdiction, as amended. h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. l. In accordance with Figure R301.2(2), where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. Section 301.2.4. R301.2.4 Floodplain construction. Buildings and structures constructed in whole or in part in flood hazard areas (including A or V zones) as established in Table R301.2, and substantial improvement and repair of substantial damage of buildings and structures located in whole or in part in flood hazard areas, shall be designed and constructed in accordance with the Tempe City Code, Chapter 12. Section 301.5 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) USE | UNIFORM LOAD (psf) | CONCENTRATED LOAD (lb) Uninhabitable attics without storage b | 10 | — Uninhabitable attics with limited storage b,g | 20 | — Habitable attics and attics served with fixed stairs | 40 | — Balconies (exterior) and decks e | 40 | — Fire escapes | 40 | — Guards | - | 200 h,i Guard in-fill components f | — | 50 h Handrail d | — | 200 h Passenger vehicle garages | 50 | 2,000 a Areas other than sleeping areas | 40 | — Sleeping areas | 40 | — Stairs | 40 c | 300 c For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kPa, 1 square inch = 645 mm 2 , 1 pound = 4.45 N. Section 302.1(1) and 302.1(2). TABLE R302.1 EXTERIOR WALLS EXTERIOR WALL ELEMENT | MINIMUM FIRE-RESISTANCE RATING | MINIMUM FIRE SEPARATION DISTANCE Walls | Fire-resistance rated | 1 hour-tested in accordance with ASTM E119, UL 263 OR Section 703.2.2 of the International Building Code with exposure from both sides | 0 feet Not fire-resistance rated | 0 hours | ≥ 5 feet Projections | Not allowed | NA | < 2 feet Fire-resistance rated | 1 hour on the underside, or heavy timber, or fire-retardant-treated wood a, b | ≥ 2 feet to < 5 feet Not fire-resistance rated | 0 hours | ≥ 5 feet Openings in walls | Not allowed | NA | < 3 feet 25% maximum of wall area | 0 hours | 3 feet Unlimited | 0 hours | 5 feet Penetrations | All | Comply with Section R302.4 | < 3 feet — | — | None required | 3 feet For SI: 1 foot = 304.8 mm. NA = Not Applicable. a. The fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave overhang if fireblocking is provided from the wall top plate to the underside of the roof sheathing. b. The fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the rake overhang where vent openings that communicate with the attic are not installed in the overhang or gable wall. c. Patios and carports fire separation distance shall be taken from walls and projections, no consideration shall be given for openings in walls. d. The fire-resistance rating of columns and projections, shall be permitted to be reduced to 0 for patios and carports constructed of noncombustible materials where the fire separation distance is 3 feet or more. TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS AND TOWNHOUSES WITH AN AUTOMATIC SPRINKLER SYSTEM EXTERIOR WALL ELEMENT | MINIMUM FIRE-RESISTANCE RATING | MINIMUM FIRE SEPARATION DISTANCE Walls | Fire-resistance rated | 1 hour-tested in accordance with ASTM E119, UL 263 OR Section 703.2.2 of the International Building Code with exposure from both sides | 0 feet Not fire-resistance rated | 0 hours | 3 feet a Projections | Not allowed | NA | < 2 feet Fire-resistance rated | 1 hour on the underside, or heavy timber, or fire-retardant-treated wood b, c | 2 feet a Not fire-resistance rated | 0 hours | 3 feet Openings in walls | Not allowed | NA | < 3 feet Unlimited | 0 hours | 3 feet a Penetrations | All | Comply with Section R302.4 | < 3 feet — | — | None required | 3 feet a For SI: 1 foot = 304.8 mm. NA = Not Applicable. a. The fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the eave overhang if fireblocking is provided from the wall top plate to the underside of the roof sheathing. b. The fire-resistance rating shall be permitted to be reduced to 0 hours on the underside of the rake overhang where vent openings that communicate with the attic are not installed in the overhang or gable wall. c. Patios and carports fire separation distance shall be taken from walls and projections, no consideration shall be given for openings in walls. d. The fire-resistance rating of columns and projections, shall be permitted to be reduced to 0 for patios and carports constructed of noncombustible materials where the fire separation distance is 3 feet or more. Section R306.1. R306.1 General. Buildings and structures constructed in whole or in part in flood hazard areas (including A or V zones) established in Table R301.2, and substantial improvement and repair of substantial damage of buildings and structures located in whole or in part in flood hazard areas, shall be designed and constructed in accordance with the provisions contained in this section and Tempe City Code, Chapter 12. Buildings and structures that are located in more than one flood hazard area, including A Zones, Coastal A Zones and V Zones, shall comply with the provisions associated with the most restrictive flood hazard area. Buildings and structures located in whole or in part in identified floodways shall be designed and constructed in accordance with ASCE 24. Section R309. R309.1 Townhouse automatic sprinkler systems. Other than where preempted by the Arizona Revised Statutes in townhouses and attached accessory uses thereto, an automatic fire sprinkler system shall be installed as required by Section P2904 R309.1.1 Design and installation. Automatic sprinkler systems for townhouses shall be designed and installed in accordance with Section P2904 or NFPA 13D. R309.2 One- and two-family dwellings automatic sprinkler systems. Other than where preempted by the Arizona Revised Statutes in one and two-family dwellings, and attached accessory uses thereto, an automatic fire sprinkler system shall be installed as required by Section P2904. Section R325.8. R325.8 Required heating and cooling. Interior spaces intended for human occupancy shall be provided with active or passive heating and cooling systems capable of maintaining an indoor temperature between 70°F (21°C) and 82°F (28°C) (if cooled by air conditioning, and 88°F (30°C) if cooled by evaporative cooling), measured at a point 3 feet (914mm) above the floor in the center of the room. The installation of space heaters or coolers shall not be used to achieve compliance with this section. Exceptions: 1. Space heating and cooling systems are not required for interior spaces where the primary purpose is not associated with human comfort. Section R310.6 & R311.6. R310.6 Power source. Smoke alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and, where primary power is interrupted, shall receive power from a battery. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Exceptions: 1. Smoke alarms shall be permitted to be battery operated where installed in buildings without commercial power. 2. Smoke alarms installed in accordance with Section R310.2.2 shall be permitted to be battery powered where alteration or repairs do not result in the removal of interior wall or ceiling finishes unless there is an attic or crawl space or basement available which could provide access for hardwiring of smoke alarms. R311.6 Power source. Carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and, where primary power is interrupted, shall receive power from a battery. Wiring shall be permanent and without a disconnecting switch other than those required for overcurrent protection. Exceptions: 1. Carbon monoxide alarms shall be permitted to be battery operated where installed in buildings without commercial power. 2. Carbon monoxide alarms installed in accordance with Section R311.2.2 shall be permitted to be battery powered where alteration or repairs do not result in the removal of interior wall or ceiling finishes unless there is an attic or crawl space or basement available which could provide access for hardwiring of smoke alarms. Section R401.3. R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard in accordance of the provisions of the Tempe City Code, Chapter 12. Lots shall be graded to drain surface water away from foundation walls. The grade shall fall not fewer than 6 inches (152 mm) within the first 10 feet (3048 mm). Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches (152 mm) of fall within 10 feet (3048 mm), drains or swales shall be constructed in accordance with the provisions of the Tempe City Code, Chapter 12, to ensure drainage away from the structure. Impervious surfaces within 10 feet (3048 mm) of the building foundation shall be sloped not less than 2 percent away from the building Section R502.3.1. R502.3.1 Sleeping areas and attic joists. Table R502.3.1(1) shall be used to determine the maximum allowable span of floor joists that support sleeping areas and attics that are accessed by means of a fixed stairway in accordance with Section R318.7 provided that the design live load does not exceed 40 pounds per square foot (92 kPa) and the design dead load does not exceed 20 pounds per square foot (0.96 kPa). The allowable span of ceiling joists that support attics used for limited storage or no storage shall be determined in accordance with Section R802.5. Section R1007.1. R1007.1 Clean Burning Fireplaces. The purpose of this standard is to regulate fireplaces, woodstoves, or other solid-fuel burning devices to reduce the amount of air pollution caused by particulate matter and carbon monoxide. The effective date of the regulations and prohibitions set forth in this standard took effect on December 31, 1998. Definitions: For purposes of this standard, the following words and terms shall be defined as follows: FIREPLACE means a built-in place masonry hearth and fire chamber or a factory-built appliance, designed to burn solid fuel or to accommodate gas or electric log insert or similar device, and which is intended for occasional recreational or aesthetic use, not for cooking, heating, or industrial processes. SOLID FUEL includes but is not limited to wood, coal, or other nongaseous or non-liquid fuels, including those fuels defined by the Maricopa County Air Pollution Control Officer as inappropriate fuel to burn in residential wood-burning devices. WOODSTOVE means a solid-fuel burning heating appliance including a pellet stove, which is either freestanding or designed to be inserted into a fireplace. R1007.2 Installation restrictions. On or after the effective date, no person, firm or corporation shall construct or install a fireplace or a woodstove, and the building official shall not approve or issue a permit to construct or install a fireplace or a woodstove, unless the fireplace or woodstove complied with one of the following: 1. A fireplace which has a permanently installed gas or electric log insert. 2. A fireplace, woodstove, or other solid-fuel burning appliance which has been certified by the United States Environmental Protection Agency as conforming to 40 Code of Federal Regulations Part 60, Subpart AAA as in effect on July 1, 1990. 3. A fireplace, woodstove or other solid-fuel burning appliance which has been tested and listed by a nationally recognized testing agency to meet performance standards equivalent to those adopted by 40 Code of Federal Regulations Part 60, Subpart AAA as in effect on July 1, 1990. 4. A fireplace, woodstove or other solid-fuel burning appliance which has been determined by the Maricopa County Air Pollution Control Officer to meet performance standards equivalent to those adopted by 40 Code of Federal Regulations Part 60, Subpart AAA as in effect on July 1, 1990. 5. A fireplace which has a permanently installed woodstove insert which complies with subparagraphs 2, 3, or 4 above. R1007.3. The following installations are not regulated by this standard and are not prohibited by this standard: 1. Furnace, boilers, incinerators, kilns, and other similar space heating or industrial process equipment. 2. Cook-stoves, barbecue grills, and similar appliances designed primarily for cooking. 3. Fire pits, barbecue grills, and other outdoor fireplaces. R1007.4 Fireplace or Woodstove Alterations Prohibited. R1007.4.1. On or after the effective date, no person, firm or corporation shall alter or remove a gas or electric log insert or a woodstove insert from a fireplace for purposes of converting the fireplace to directly burn wood or other solid fuel. R1007.4.2. On or after the effective date, no person, firm or corporation shall alter a fireplace, woodstove or other solid fuel burning appliance in any manner that would void its certification or operational compliance with the provisions of this standard. R1007.5 Permits Required. In addition to the provisions and restrictions of this standard, construction, installation or alteration of all fireplaces, woodstoves and other gas, electric or solid-fuel burning appliances and equipment shall be done in compliance with provisions of this Code and shall be subject to the permits and inspections. Section N1103.10.3. N1103.10.3 (R403.10.3) Covers. Outdoor heated pools and outdoor permanent spas shall be provided with a vapor-retardant cover or other approved vapor-retardant means. Exception: 1. Where more than 75 percent of the energy for heating, computed over an operation season of not fewer than 3 calendar months, is from a heat pump or an on-site renewable energy system, covers or other vapor-retardant means shall not be required. 2. Where pools are equipped with variable speed pump motors. Section N1111.1.2. N1111.1.2 (R503.1.2) Heating and cooling systems. New heating and cooling systems and duct work that are part of an alteration shall comply with Section N1103 and this section. Alterations to existing heating and cooling systems and duct work shall comply with this section. Exception: 1. Where ductwork from an existing heating and cooling system is extended. 2. Where additions are 250 square feet or less and do not exceed the capacities of the existing system. Section P2603.5.1. P2603.5.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be not less than 12 inches (305mm) below finished grade at the point of septic tank connection. Building sewers shall be not less than 12 inches (305mm) below grade. Section E3901.4.2 & E3901.4.3. E3901.4.2 Island and peninsular countertops and work surfaces. At least one receptacle outlet shall be installed at each island countertop space with a long dimension of 24 inches (610 mm) or greater and a short dimension of 12 inches (305 mm) or greater. Not less than one receptacle outlet shall be installed at each peninsular countertop long dimension space having a long dimension of 24 inches (610 mm) or greater and a short dimension of 12 inches (305 mm) or greater. A peninsular countertop is measured from the connected perpendicular wall. E3901.4.3 Receptacle outlet location. Receptacle outlets rendered not readily accessible by appliances fastened in place, appliance garages, sinks, or rangetops as covered in the exception to Section E3901.4.1, or appliances occupying assigned spaces shall not be considered as these required outlets. Required receptacle outlets shall be located in one or more of the following: 1. On or above, but not more than 20 inches (508 mm) above, the countertop or work surface. 2. In a countertop using receptacle outlet assemblies listed for the use in countertops. 3. In a work surface using receptacle outlet assemblies listed for use in work surfaces or listed for use in countertops. [210.52(C)(3)] 4. Receptacle outlets shall be permitted to be mounted not more than 12 inches (305 mm) below the countertop or work surface in construction designed for the physically impaired and for island and peninsular countertops or work surface where the surface is flat across its entire surface and there are no means to mount a receptacle within 20 inches (508 mm) above the countertop, such as in an overhead cabinet. Receptacles mounted below the countertop or work surface in accordance with this exception shall not be located where the countertop or work surface extends more than 6 inches (152 mm) beyond its support base. Section P2904.1.1. P2904.1.1 Required sprinkler locations. Sprinklers shall be installed to protect all areas of a dwelling unit of livable, including garages and carport areas, greater than 5000 square feet. Exceptions: 1. Attics, crawl spaces and normally unoccupied concealed spaces that do not contain fuel-fired appliances do not require sprinklers. In attics, crawl spaces and normally unoccupied concealed spaces that contain fuel-fired equipment, a sprinkler shall be installed above the equipment; however, sprinklers shall not be required in the remainder of the space. 2. Clothes closets, linen closets and pantries not exceeding 24 square feet (2.2 m 2 ) in area, with the smallest dimension not greater than 3 feet (915 mm) and having wall and ceiling surfaces of gypsum board. 3. Bathrooms not more than 55 square feet (5.1 m 2 ) in area. Appendix BB, Section BB102-Definitions TINY HOUSE. A dwelling that is not less than 120 square feet (18.58 m2) and not more than 400 square feet (37 m2) in floor area excluding lofts, that is not under the authority of the Arizona Department of Housing, Manufactured Housing Division, or constructed as a recreational vehicle as determined by the building official. Appendices Adoption Adopt the following appendices: Appendix BB - Tiny Houses Appendix BF - Patio Covers Appendix BG - Sound Transmission Appendix BO - Existing Buildings and Structures Appendix CA - Sizing and Capacities of Gas Piping Appendix CB - Sizing of Venting Systems Serving Appliances Equipped with Draft Hoods, Category 1 Appliances and Appliances Listed for Use with Type B Vents. Appendix CD - Piping Standards for Various Appliances Appendix CE - Venting Methods Appendix CF - Sizing of Water Piping System Appendix NB - (Rb) Solar-Ready Provisions - Detached One- and Two-Family Dwellings and Townhouses

(Ord. No. O2018.59, §§ 1, 4, 8-30-18; Ord. No. O2026.24, § 4(Exh. A), 6-4-26)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.