For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-800 — Adopted; where filed; amendments

The Code of the City of Tempe, Arizona (Supp. No. 34, Update 1: codified through Ordinance No. O2026.34, enacted June 25, 2026) · Tempe City Code § 8-800

Corpus is an independent public-information project, not the official City of Tempe website. Stable reference: corpuslaw.us/code/706f9dff-7498-4d7c-9bdb-c3082bfde0c3

Sec. 8-800. - Adopted; where filed; amendments.

That certain document known as "The National Electrical Code, 2023 Edition," that which has been published as a code in book form by the National Fire Protection Association entitled National Electrical Code, N.F.P.A. No. 70-2023 edition, article ninety and chapters one through nine, three (3) copies with amendments of which are on file in the office of the City Clerk, and this same code, and amendments are hereby referred to, adopted and made a part of, as if fully set out in this article. Article 90 Introduction Notes: 1. For reserved sections herein, refer to the City of Tempe Administrative Code for these code requirements. 2. Any conflicts between this code and the Tempe Administrative Code, the Tempe Administrative Code shall apply. 90.1 Scope. This article covers use and application, arrangement, and enforcement of this Code. It also covers the expression of mandatory, permissive, and nonmandatory text, provides guidance on the examination of equipment and on wiring planning, and specifies the use and expression of measurements. 90.1.1 Title. These regulations shall be known as the National Electrical Code as amended by the City of Tempe hereinafter referred to as "this code or NEC". These regulations are one document of the overall City of Tempe Construction Code as defined by the adopting ordinance. 90.1.2 Authority. Where used in this article, the term authority having jurisdiction shall include the building official or other individuals designated by the building official. This Code shall be administered and enforced by the authority having jurisdiction designated by the governing authority as follows: 1. The authority having jurisdiction shall be permitted to render interpretations of this Code in order to provide clarification to its requirements, as permitted by 90.4. 2. When the use of any electrical equipment or its installations is found to be dangerous to human life or property, the authority having jurisdiction shall be empowered to have the premises disconnected from its source of electric supply. When such equipment or installation has been so condemned or disconnected, a notice shall be placed thereon listing the causes for the condemnation, the disconnection, or both, and the penalty established by 80.23 for the unlawful use thereof. Written notice of such condemnation or disconnection and the causes therefore shall be given within 24 hours to the owners, the occupant, or both, of such building, structure, or premises. It shall be unlawful for any person to remove said notice, to reconnect the electrical equipment to its source of electric supply, or to use or permit to be used electric power in any such electrical equipment until such causes for the condemnation or disconnection have been remedied to the satisfaction of the inspection authorities. 3. The authority having jurisdiction shall be authorized to inspect, at all reasonable times, any building or premises for dangerous or hazardous conditions or equipment as set forth in this Code. The authority having jurisdiction shall be permitted to order any person(s) to remove or remedy such dangerous or hazardous condition or equipment. Any person(s) failing to comply with such order shall be in violation of this Code. 4. Where the authority having jurisdiction deems that conditions hazardous to life and property exist, he or she shall be permitted to require that such hazardous conditions in violation of this Code be corrected. 5. The authority having jurisdiction shall be permitted to investigate the cause, origin, and circumstances of any fire, explosion, or other hazardous condition. 6. The authority having jurisdiction shall be permitted to require plans and specifications to ensure compliance with this Code. 7. Whenever any installation subject to inspection prior to use is covered or concealed without having first been inspected, the authority having jurisdiction shall be permitted to require that such work be exposed for inspection. The authority having jurisdiction shall be notified when the installation is ready for inspection and shall conduct the inspection. 90.1.3 Inspections and Approvals. Inspections shall be made throughout the installation process and shall be requested by the permit holder. Work shall not be continued until required inspections has been passed. 1. Upon the completion of any installation of electrical equipment that has been made under a permit other than an annual permit, it shall be the duty of the person, firm, or corporation making the installation to notify the building official, who shall cause the work to be inspected. 2. Underground electrical work shall be inspected and made prior to the concealing any of the work or conduits 3. Rough Electrical work shall be inspected prior to being covered by other materials and prior to the installation of fixtures 4. Electrical Equipment Inspection. Prior to energizing all wiring within the panel shall be secured and landed. 5. Other electrical inspections, special inspections, observation and reports as required by the building official. 6. Final Electrical Inspection. Electrical shall be energized and all over current protection devices are to be in place and all required arc fault, ground fault interruption, fuses, surge protection devices and all other protection devices installed in their permanent location. 90.1.4 Connection to Electricity Supply. Connections to the electric supply shall conform to 80.25(A) through (C). (A) Authorization. Except where work is done under an annual permit and except as otherwise provided in 80.25. it shall be unlawful for any person, firm, or corporation to make connection to a supply of electricity or to supply electricity to any electrical equipment installation for which a permit is required or that has been disconnected or ordered to be disconnected. (B) Special Consideration. By special permission of the authority having jurisdiction, temporary power shall be permitted to be supplied to the premises for specific needs of the construction project. (C) Disconnection. Where a connection is made to an installation that has not been inspected, as outlined in the preceding paragraphs of this section, the supplier of electricity shall immediately report such connection to the Building Official. If, upon subsequent inspection, it is found that the installation is not in conformity with the provisions of Article 80, building official shall notify the person, firm, or corporation making the installation to rectify the defects immediately without delay or a longer period of time as determined by the building official. If such work is not completed within the period as may be specified, the building official shall have the authority to cause the disconnection of that portion of the installation that is not in conformity. Article 110.2 110.2 Approval. The conductors and equipment required or permitted by this Code shall be acceptable only if approved. 110.2.1 Electrical special inspections and observation. The owner or the owner's authorized agent, other than the contractor, shall employ the registered design professional responsible for the electrical design or one or more approved agencies designated by the registered design professional responsible for the electrical design to perform visual observations of complex electrical equipment and systems for general conformance to the approved plans and specification, including but not limited to, placement and interconnection of equipment and shall identify the approved agencies to the building official in accordance with Section 1704.2 of the International Building Code as amended. Electrical observations shall be performed at significant stages of the construction when the installation is complete and ready for inspection. Electrical observations are in addition to and not in lieu of inspections required by Section 110 of the Tempe Administrative Code and Section 1705.12.6 of the International Building Code, and shall be provided when one of the following conditions exist: 1. Ground-fault protection performance tests for equipment with ground-fault protect. 2. Switch boards, panelboards, motor control centers and other equipment rated at 1,000 amperes or more or over 600 volts. 3. The installation or alteration of electrical systems over 600V. 4. Transformers rated 100 kVA or more, single phase or 300 kVA or more three-phase. 5. Insulation integrity of conductors that supply equipment rated at 1,000 amperes or more, or over 600 volts. 6. Emergency and standby power systems, including switchboards, panelboards, distribution boards, transfer equipment, power source, conductors, fire pumps, exhaust and ventilation fans. 7. Selective Coordination - This includes verification of the installation in accordance with the required selective coordination study. 8. The installation or alteration of that portion of a health care facility's electrical system which fall under the scope of Article 517 of this code, including such systems installed in facilities where outpatient surgical procedures are performed. 9. The installation or alteration of electrical systems within locations classified as hazardous by provisions of this code, except for gasoline dispensing installations and systems located within storage garages, repair garages or lubritorium's. 10. Special cases - Work which, in the opinion of the building official, involves unusual hazards or conditions. Article 110.7 110.7 Wiring Integrity. Completed wiring installations shall be free from short circuits, ground faults, or any connections to ground other than as required or permitted elsewhere in this code. All equipment rated at 1,000 amperes or more shall be tested for insulation breakdown prior to its being energized. This test shall be performed by an independent testing facility or agency approved by the authority having jurisdiction and in accordance with this code. Article 210.52 210.52 (G)(1) Garages. In each attached garage and in each detached garage that is provided with electric power, at least one GFCI receptacle outlet shall be installed in each vehicle bay at not less than 457 mm (18 in.) and not more than 1.7 m (5½ ft.) above the floor. Article 215.25 215.25 Feeder Circuits in Attached Single-Family Dwellings (Townhouses). Dwelling Unit Feeders. Feeder circuits in each dwelling unit of attached one-family dwellings (townhouses) shall supply only loads within that dwelling unit or loads associated with that dwelling unit. Feeders serving adjoining townhouse dwelling units shall not pass through, above, below, or be attached to other townhouse dwelling units. This applies regardless of ownership of the individual townhouse units. Article 250.118 250.118 Types of Equipment Grounding Conductors. The equipment grounding conductor run with or enclosing the circuit conductors shall be one or more or a combination of the following: (4) Electrical metallic tubing with an additional equipment grounding conductor.

(Ord. No. O2018.59, §§ 1, 9, 8-30-18; Ord. No. O2026.24, § 9(Exh. A), 6-4-26)

Ask a question about Tempe law

Corpus searches the Tempe sections it holds and shows the ones that match, with their citations. Free, no sign-in.