13-31.4 - Noise Insulation from Exterior Sources.

a. Location and Orientation. Consistent with land use standards, residential structures located in noise critical areas, such as proximity to select system of County roads and City streets (as specified in Section 186.4 of the State of California Streets and Highways Code), railroads, rapid transit lines, airports, or industrial areas shall be designed to prevent the intrusion of exterior noises beyond prescribed levels with all exterior doors and windows in the closed position. Proper design shall include, but shall not be limited to, orientation of the residential structure, setbacks, shielding, and sound insulation of the building itself. b. Interior Noise Levels. Interior community noise equivalent levels (CNEL) with windows closed, attributable to exterior sources shall not exceed an annual CNEL of forty-five (45) dB in any habitable room. c. Airport Noise Source. Residential structures to be located within an annual CNEL contour (as defined in Title 4, Subchapter 6, California Administrative Code) of sixty (60) dB require an acoustical analysis showing that the structure has been designed to limit intruding noise to the prescribed allowable levels. CNEL's shall be as determined by the general plan. d. Vehicular and Industrial Noise Sources. 1. Residential buildings or structures to be located within exterior community noise equivalent level contours of sixty (60) dB of an existing or adopted freeway, expressway, major street, thoroughfare, bridge, railroad, rapid transit line or industrial noise source shall require an acoustical analysis showing that the proposed building has been designed to limit intruding noise to the prescribed allowable levels. CNEL's shall be as determined by the general plan. 2. Exception: Railroads, where there are no nighttime (10:00 p.m. to 7:00 a.m.) railway operations and where daytime (7:00 a.m. to 10:00 p.m.) railway operations do not exceed four (4) per day. e. Parks, Playgrounds and Schools. Residential buildings or structures to be located within exterior community noise equivalent level contours of sixty (60) dB of an existing park, playground or school shall require an acoustical analysis showing that the proposed building has been designed to limit intruding noise to the prescribed allowable levels. CNEL's shall be as determined by the general plan. f. High Exposure Area. Buildings located within a high exposure area shall require an acoustical analysis showing that the structure has been designed to limit noise to the prescribed allowable levels. CNEL's shall be as determined by the general plan.

(Ord. No. 1750 N.S.; Ord. No. 2722 N.S. § 2)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.