13-38.18 - Electrical Wiring and Service.

a. General. The provisions of this subsection cover the electric conductors and equipment installed within or on the floating homes and the conductors that connect floating homes to the supply of electricity. Wherever requirements of the National Electrical Code and this subsection differ, the requirements of this subsection shall apply. The provisions of this subsection apply to floating homes only. A wiring system nominally rated 115/230 volts, three (3) wire AC, with grounded neutral shall be used. b. Branch Circuits, Feeders and Calculations. Branch circuits, feeders and calculations, shall correspond to requirements for a single unit of a multi-family dwelling and comply with the National Electrical Code and the Alameda Rules and Regulations Articles Nos. 210-215 and 220. c. Services. Service equipment shall be placed ashore and shall comply with the National Electrical Code and the Alameda Rules and Regulations Article 230 in all applicable respects. Power supply from dock or shore to floating homes shall be cord, Type SSO or ST, installed in compliance with the National Electrical Code Article No. 400 with one (1) conductor in the cord for grounding only, in addition to the neutral conductor. Individual cord over current protection shall not exceed fifty (50) amperes. Not more than two (2) cords may be installed to supply one (1) vessel. Cords shall be fitted with an approved separable connector at the shore end and direct connected at the vessel distribution panel. The cord shall be supported with a corrosion resistant mesh type strain relief device at the vessel end. d. Grounding. The neutral terminal block of the vessel's distribution panel shall not be grounded to the metal parts of the vessel. The grounding conductor or conductors of the supply cord or cords shall be terminated on a grounding bus in the distribution panel. The hull, if metal, and electrical equipment, metallic piping, exposed metal structural members, metal railing, ladders, etc., shall be effectively bonded to the ground bus. If the hull is built of material other than metal, a ground electrode of corrosion-resistant metal shall be so located as to be in contact with the water and be connected with #6 AWG copper wire to the ground bus. The electrode shall be of bronze or brass and not smaller than one-quarter (1/4″) inch diameter and eighteen (18″) inches in length. e. Wiring Methods. 1. Installation in wood frame construction may be in accordance with the National Electrical Code Article No. 336 "Non-Metallic Sheathed Cable," except that exposed work will not be permitted in living areas. 2. The following methods are acceptable for all types of construction: (a) National Electrical Code, Article No. 330. Mineral Insulated-Metal Sheathed Cable. (b) National Electrical Code, Article No. 333. Armored Cable. (c) National Electrical Code, Article No. 334. Metal-clad Cable. (d) National Electrical Code, Article No. 338. Service Entrance Cable. Use in accordance with Alameda Rules and Regulations, Article No. 338. (e) National Electrical Code, Article No. 346. Rigid Metal Conduit. (f) National Electrical Code, Article No. 348. Electrical Metallic Tubing. (g) National Electrical Code, Article No. 351. Liquid-tight Flexible Metal Conduit. (h) National Electrical Code, Article No. 352. Surface Metal Raceways.

(Ord. No. 1610 N.S.; Ord. No. 2722 N.S. § 7)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.