For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-70.2 — Scope

Municipal Code of the City of Alameda, California (Codified through Ordinance No. 3398 N.S., passed April 21, 2026. (Supp. No. 74)) · Alameda Municipal Code § 13-70.2

Corpus is an independent public-information project, not the official City of Alameda website. Stable reference: corpuslaw.us/code/360d95f7-c98d-4fe4-be22-bb47e3340b53

13-70.2 - Scope.

This chapter sets standards for strengthening that may be approved by the building official without requiring plans or calculations prepared by an architect or engineer. In accordance with the restrictions outlined below one (1) of two (2) prescriptive standards may be used. a. Standard Plan A — Residential Seismic Strengthening Plan. The provisions of this article may be applied to one (1) and two (2) story, conventional light-frame wood construction, Group R, Division 3 Occupancies. 1. The provisions of this article do not apply to buildings or elements thereof, listed below. (a) Buildings without a continuous perimeter concrete foundation. (b) Buildings with cripple walls that exceed four (4′) feet in height. (c) Buildings exceeding two (2) stories in height. (d) Buildings or portions thereof, constructed on a concrete slab on grade. (e) Buildings where the building official determines conditions exist that are beyond the scope of the prescriptive requirements of this chapter. b. Chapter A3 2006 International Existing Building Code. The provisions of this article may be applied to one (1) to two (2) story, conventional light-frame wood construction, Group R, Division 3 Occupancies, containing one (1) or more of the structural weaknesses specified in Section 13-70.2(b)(2). 1. The provisions of this section do not apply to the buildings, or elements thereof, listed below. These buildings or elements require analysis by an engineer or architect in accordance with Section A301.3 of the 2006 International Existing Building Code to determine appropriate strengthening: (a) Group R-1, R-2 or R-4 occupancies with more than four dwelling units; (b) Buildings with a lateral-force-resisting system using poles or columns embedded in the ground; (c) Cripple walls that exceed four (4') feet in height; (d) Buildings exceeding three (3) stories in height and any three (3) story building with cripple wall studs exceeding fourteen (14″) inches in height; (e) Buildings where the building official determines that conditions exist that are beyond the scope of the prescriptive requirements of Chapter A3 of the 2006 International Existing Building Code; (f) Buildings or portions thereof constructed on concrete slabs on grade. 2. Structural Weaknesses. For the purposes of this section structural weaknesses shall be as specified below. (a) Sill plates or floor framing that are supported directly on the ground without an approved foundation system. (b) A perimeter foundation system that is constructed only of wood posts supported on isolated pad footings. (c) Perimeter foundation system that is not continuous. Exceptions: i. Existing single story exterior walls not exceeding ten (10') feet in length, forming an extension of floor area beyond the line of an existing continuous perimeter footing; ii. Porches, storage rooms, and similar spaces not containing fuel-burning appliances. (d) A perimeter foundation system that is constructed of unreinforced masonry or stone. (e) Sill plates that are not connected to the foundation or that are connected with less than what is required by the building code. Exceptions: i. When approved by the building official connections of a sill plate to the foundation made with other than sill bolts may be accepted if the capacity of the connection is equivalent to that required by the building code. (f) Cripple walls that are not braced in accordance with the requirements of Section A304.4 and Table A3-A of the 2006 International Existing Building Code, or cripple walls not braced with diagonal sheathing or wood structural panels in accordance with the building code.

(Ord. No. 2950 N.S. § 1)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.