13-80.3 - Findings and Intent.

(a) The City of Alameda is located within Design Category D & E, as defined in the 2007 California Building Code. (b) The City Council desires to lessen the risks to life and property of the residents of the City of Alameda posed by a major earthquake along the Hayward Fault. (c) Buildings with soft, weak or open front ground floor stories are recognized by engineers, and other seismic safety experts, as having potential for sustaining serious damage including collapse, in the event of strong earthquakes. (d) Neither the International Building Code nor the California Building Standards Code contains provisions governing the earthquake retrofit of soft-story residential buildings. (e) In 2006, the International Code Counsel [Council] published the second edition of the International Existing Building Code (IEBC). Chapter A4 of that code, entitled "Earthquake Hazard Reduction in Existing Wood-Fame [Wood-Frame] Residential Buildings with Soft, Weak, or Open-Front Walls", which is the basis for this chapter. (f) In 2005, California Health and Safety Code sections 19162 and 19163 were amended to expressly authorize local jurisdictions the authority to adopt by ordinance retrofit standards for soft-story residential buildings that comply with a nationally recognized model code relating to the retrofit of existing buildings or substantially equivalent standards. (g) The current nationally recognized model code for the retrofit of soft-story residential buildings is Appendix Chapter A4 of the 2006 IEBC. The provisions of this chapter, as amended by this Article, comply with or are substantially equivalent to Appendix Chapter A4 of the IEBC. (h) These codes are not intended to provide structural performance equivalent to that provided by new construction built to the current City Building Code, rather these codes identify and provide for improving the structure's more vulnerable portions and, if identified improvements are made, can be expected to substantially reduce the likelihood of excessive building drift or collapse and substantially lessen the loss of human life. (i) The establishment of an inventory of soft-story buildings and the notification of owners and residents is a necessary first step in developing a mitigation program and will provide the basis for obtaining input from affected parties for any future mandatory retrofit program. (j) Although the general vulnerability of such buildings is known, determining the seismic adequacy of each of the structures and the appropriate elements of a retrofit to remedy vulnerabilities requires a detailed evaluation by a licensed engineer. (k) Such an evaluation is also necessary for the City to identify fully the risks to the city and its inhabitants and to determine the feasibility of programs to address the vulnerabilities. (l) This Article requires the establishment of an inventory of potentially hazardous, wood frame, multi-unit (five (5) units or more) residential structures with soft-story, weak or open front walls; provides for notification of the owners, residents, and users of such buildings; adopts Appendix Chapter A4 of the 2006 IEBC and requires owners to provide analysis of their building's seismic adequacy.

(Ord. No. 2989 N.S. § 1)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.