6-3.6 - General Specifications for Signs.

a. All signs shall be designed, erected and maintained to withstand wind loadings from any direction as follows, the detail design to be in accordance with the provisions of the Building Laws of the City: 1. For solid surface signs, twenty (20) pounds per square foot on any one (1) face of sign. 2. For skeleton surface signs, thirty (30) pounds per square foot of the total face area of the letters or other sign surface, or ten (10) pounds per square foot on the gross area within the frame of the sign proper, whichever is the greater. b. Metal shapes or flats used for supporting or bracing signs shall be no less than one-eighth (⅛″) inch thick and shall be galvanized or the equivalent. Where wire is used to support or brace signs, it shall be galvanized or the equivalent. c. Glass panels or panes shall be not less than three-sixteenths ( 3/16 ″) inch in thickness; shall be continuously and securely supported by metal on all edges of each piece; shall not exceed three hundred (300) square inches in area in any one (1) piece; provided, however, that when the glass is contained entirely within the body of a sign having closed bottom and closed ends or edges and is covered with metal except for areas cut out to form letters or other characters, the glass may be not less than one-eighth (⅛″) of an inch in thickness, need not be continuously supported along all edges, and will not be subject to the above limitations as to area, but the height of any individual letter or other character formed as above described shall not exceed twenty-four (24″) inches; further provided, that glass transparencies over three hundred (300) square inches and not more than six hundred (600) square inches in any one piece will be allowed if the glass used is not less than one-quarter (¼″) inch wire plate glass. d. Nothing in paragraph c. shall be construed to prohibit signs of so called leaded art glass construction. Such art glass signs shall be made up in panels not to exceed eighteen (18″) inches in any dimension and every such panel shall be supported in a galvanized iron or noncorrosive metal frame. Such art glass signs shall not contain any one (1) piece of glass larger in size than thirty-six (36″) square inches; one (1) dimension in length or width of every such piece of glass shall be less than four (4″) inches; and every such piece of glass shall be firmly and continuously secured and supported on both sides along all edges by noncorrosive metal. e. All cloth signs shall have a rigid wood or metal frame, and shall extend not more than six (6″) inches from the face of a building, and shall not be permitted to hang for a period exceeding ninety (90) days. All signs projecting more than six (6″) inches from the face of a building shall be of wood or noncombustible material; provided that all signs projecting more than eighteen (18″) inches from the face of a building shall be constructed throughout of metal or of metal and glass. f. Exception; Wood Sign. A wood sign may extend more than eighteen (18″) inches from the face of the building if the following conditions are met: 1. The sign shall have a net dimension of not less than two (2″) inches thick. 2. The sign shall not extend beyond the property line on which the building sits. 3. The sign shall not be an electric sign. 4. The sign shall not be a roof sign. g. Temporary signs, advertisements, flags and banners may be suspended over the street upon holidays, election days and days of public parade or display, provided that the same shall be placed and secured subject to the direction of the City Manager and be removed immediately following the days for which they have been suspended. With the special permission of the City Manager, however, such temporary signs, flags and banners may be suspended in front of theatres, hotels and other places of business on days other than those above specified. h. Every electric street sign shall be illuminated by incandescent lamps having a total rated wattage at least equal to twelve (12) watts per square foot area of the exposed face or faces of the sign, or by luminous tubing of total length at least equal to nine (9) linear inches per square foot area of such face or faces, or by other equivalent approved electric illuminant. In every electric street sign, every letter and figure shall be formed or clearly outlined by incandescent lamps, luminous tubes or other approved electric illuminant contained within the sign; provided, that minor or secondary letters or figures not exceeding four (4″) inches in height need not be so formed or outlined if the sign contains larger letters and figures which are individually so formed or outlined and which constitute the principal wording or information displayed by the sign. The illuminating elements in and on all signs shall be maintained in good order and in the full number for which the sign was designed, and failure to so maintain such illuminating elements shall constitute a discontinuance of use within the purview of subsection 6-3.5c. i. No sign other than electric signs and fixed horizontal double face nonelectric signs provided for in subsection 6-3.7f. shall project more than eighteen (18) inches from the face of a building, and no sign other than a double face vertical sign or a double face horizontal sign shall extend above the eaves or parapet of the building to which it is attached. j. No double or triple face electric signs shall be more than four (4) feet thick between sign faces. k. No sign which projects more than ten (10) inches from the face of a building shall be less than eight (8) feet above the sidewalk; provided, however, that this provision shall not apply to barber pole signs or to sidewalk clocks legally erected. No sign shall project beyond the face of the curb below. l. No sign shall be attached to any fire escape, standpipe, or window, nor shall any sign extend across or in front of any window or other exterior opening in any building above the first story thereof in such a way as to obstruct the ingress or egress from such building; nor shall any sign extend across any mezzanine floor in such a manner as to leave less than two (2) feet of window or glass front exposed. m. All signs hereafter erected in the City shall bear the date of erection or the building permit number clearly painted thereon in characters one (1) inch in height, provided, however, that electric signs may have attached thereto an approved metal tag in lieu of the painted characters. n. No advertising structure shall exceed fifty (50) square feet in area.

(Ord. No. 535 N.S. 12-251—12-2512; Ord. No. 1858 N.S.; Ord. No. 1958 N.S.)

Ask a question about Alameda law

Corpus searches the Alameda sections it holds and shows the ones that match, with their citations. Free, no sign-in.