For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 15.40.080 — Tables and standards

Municipal Code of the City of Bakersfield, California (Bakersfield Municipal Code current through Ordinance 5223, passed August 26, 2026 (municipal.codes publication, scraped 2026-11-17)) · Bakersfield Municipal Code § 15.40.080

Corpus is an independent public-information project, not the official City of Bakersfield website. Stable reference: corpuslaw.us/code/5af0b155-6c14-40e0-88eb-2703b5db9a5a

15.40.080 Tables and standards.

For time limits and technical specifications see Table Nos. 1-A, 1-B, 1-C, and 1-D; Standard Nos. 24-7 and 24-9. TABLE NO. 1-A TIME LIMITS FOR PROCEEDINGS FOLLOWING DECEMBER 31, 1998 DEADLINE Required Action By Owner | Obtain Building Permit Within | Commence Construction Within | Complete Construction Within Anchorage Installation | 1 Year(1) | 180 Days(2) | 1 Year(2) Buildings to be Demolished | 1 Year(1) | 180 Days(2) | 1 Year(2) TABLE NO. 1-B ALLOWABLE VALUES FOR TENSION ANCHORS Type of Installation | Allowable Values(1) Type of Installation | Allowable Values(1) EXISTING TENSION ANCHORS: Anchors at floor level embedded in brick (to be tested per Section 15.40.050B). | Allowable shall be 40% of the average of the tests for anchors having same wall thickness and joist orientation. Anchors at floor or roof levels embedded in existing concrete or gunite on the opposite side of the wall.(2) | 1800 lb. per anchor. TENSION BOLTS: Bolts extending entirely through unreinforced masonry walls secured with bearing plates on far side of a 3 wythe minimum wall with a bearing plate having an area of at least 30 square inches.(2)(3) | 1800 lbs. per bolt. 900 lbs. for 2 wythe walls. COMBINATION TENSION AND SHEAR BOLTS: Combination tension and shear bolts are tension bolts centered in a 2½ inch diameter by 8 inch minimum depth hold with dry-pack or nonshrink grout around the circumference of bolt. | Same as for tension bolts. EMBEDDED BOLTS: Bolts extending to the exterior wall with a 2½ inch round plate under the head and drilled at an angle of 22½ degrees to the horizontal. Bolts shall be centered in 2½ inch diameter holes with dry-pack or non-shrink grout around circumference of bolts. Bolts shall be tested per Section 15.40.050C. | 1200 pounds. TABLE NO. 1-C HORIZONTAL FORCE FACTOR “Cp” FOR PARTS OR PORTIONS OF BUILDINGS OR OTHER STRUCTURES Part or Portion of Buildings | Direction of Force | Value of Cp Part or Portion of Buildings | Direction of Force | Value of Cp Exterior bearing and nonbearing walls; interior bearing walls and partitions; interior nonbearing walls and partitions over 10 feet in height. | Normal-to-flat surface | 0.3 Cantilever parapet and other cantilever walls, except retaining walls. | Normal-to-flat surface | 1.00 Exterior and interior ornamentations and appendages. | Any direction | 1.00 Prefabricated structural elements, other than walls, with force applied at center of gravity of assembly. | Any horizontal direction | 0.30 Connections for exterior panels or elements. | Any direction | 2.00 TABLE NO. 1-D ALLOWABLE VALUE OF HEIGHT-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS WITH MINIMUM QUALITY MORTAR Buildings with Crosswalls As Defined by Section 15.40.030 | All Other Buildings Walls of one-story buildings | 16 | 13 First-story walls of two-story buildings | 16 | 15 Walls in top story of multi-story buildings | 14 | 9 All other walls | 16 | 13

Ask a question about Bakersfield law

Corpus searches the Bakersfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.