§ 18.208.070 — Breakaway walls
City Code, City of Buena Park, California (Includes legislation through Ord. No. 1769 adopted July 14, 2026) · Buena Park City Code § 18.208.070
Corpus is an independent public-information project, not the official City of Buena Park website. Stable reference: corpuslaw.us/code/7a51af3c-0c60-41d1-94dc-b99cae00eb3b
§ 18.208.070: Breakaway walls.
"Breakaway walls" means any type of walls, whether solid or lattice, and whether constructed of concrete, masonry, wood, metal, plastic or any other suitable building material which is not part of the structural support of the building and which is designed to break away without causing any damage to the structural integrity of the building on which they are used or any buildings to which they might be carried by floodwaters. A breakaway wall shall have a safe design loading resistance of not less than ten and no more than twenty pounds per square foot. Use of breakaway walls must be certified by a registered engineer or architect and shall meet the following conditions: A. Breakaway wall collapse shall result from a water load less than that which would occur during the base flood; and B. The elevated portion of the building shall not incur any structural damage due to the effects of wind and water loads acting simultaneously in the event of the base flood.
( Ord. 1210 § 3 (2.0 (6)), 1987 )
Ask a question about Buena Park law