For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.348.110 — Cottage Cluster Developments

City Code, City of Buena Park, California (Includes legislation through Ord. No. 1769 adopted July 14, 2026) · Buena Park City Code § 19.348.110

Corpus is an independent public-information project, not the official City of Buena Park website. Stable reference: corpuslaw.us/code/0ad5b4df-38bb-4b99-8984-8c3904eb5a40

§ 19.348.110: Cottage Cluster Developments.

A. Purpose. The purpose of this section is to encourage affordable detached cottage cluster developments that include between four (4) and ten (10) smaller single-family residential units arranged around a shared court visible from the street on parcels 20,000 square feet or more in size in the RS-8 and RS-6 zones. B. Submittal Requirements and Application Processing. Any application for a cottage cluster development shall include a site plan, floor plan, and elevations substantiating and evidencing compliance with all applicable development standards. Cottage cluster developments that do not provide a minimum of 80% affordable housing shall be subject to discretionary review. Where all requirements of this section and the Buena Park City Code are met, the application shall be approved ministerially without discretionary review or public hearing within 60 days of receiving the application for affordable housing exceeding the minimum 80% affordability requirement. The City and applicant may agree to additional time with a written request from the applicant. C. Development and Objective Design Standards. 1. Site Dimensions. The minimum site dimensions for cottage cluster developments in the RS-8 and RS-6 zones is shown in the table below. Site Dimensions | RS-8 | RS-6 Minimum Lot Area (square feet) | 24,000 sq. ft. | 20,000 sq. ft. Minimum Street Frontage (lineal feet) | 150 ft. | 100 ft. Minimum Lot Width (lineal feet) | 150 ft. | 100 ft. Minimum Lot Depth (lineal feet) | 150 ft. | 100 ft. 2. Setbacks. The minimum setbacks for cottage cluster developments are shown in the table below. Minimum Front Yard Setbacks (Property Line to Dwelling) | 20 feet Minimum Side Yard Setbacks (Property Line to Dwelling) | 15 feet Minimum Rear Yard Setbacks (Property Line to Dwelling) | 20 feet Minimum Setbacks from Dwellings to Parking Lot | 15 feet Minimum Building Separation (Side to Side) | 5 feet 3. Lot Coverage. The lot coverage for cottage cluster developments shall not exceed 60%. 4. Building Height. The maximum building height shall not exceed two (2) stories or thirty (30) feet, whichever is less. Building projections shall meet the requirements set forth in Section 19.320.020. 5. Density. Density requirements shall be pursuant to the density standards of the underlying zone. Cluster bonuses may be applied to cottage cluster developments, although the number of units per cottage cluster on a single parcel shall not exceed ten (10) units in any RS zone. 6. Floor Area. The minimum floor area for each cottage cluster unit within the development shall be a minimum of 600 square feet and a maximum of 1,200 square feet. Attached garages are not required. If an attached garage is provided, the floor area shall not be less than 1,200 square feet. The attached garage shall be included as part of the minimum floor area requirement. 7. Parking. The cottage cluster development is exempt from minimum parking requirements if the development is located within a half-mile from public transit or located within one (1) block of a dedicated car share lot. a. Garage parking is not required. If garage parking is provided, each unit shall maintain a minimum 400 square foot garage consisting of 2 parking spaces 10 feet in width and 20 feet in length. Garages shall not be shared by more than one (1) cottage cluster unit. Garages shall be attached to the cottage cluster unit but shall not abut common open spaces. Parking may also be located in the driveway in front of the garage provided that the driveway has a minimum width of 8 feet per space and minimum length of 20 feet and is not shared with any other unit. b. On-site parking for cottage cluster developments shall provide a minimum of one (1) parking space per unit with up to two (2) bedrooms, two (2) parking spaces per unit with three (3) bedrooms, and three (3) parking spaces per unit with four (4) bedrooms or more. Guest parking shall provide a minimum of 0.5 parking spaces per unit, regardless of the number of bedrooms. c. Parking Lots. (i) Parking spaces in a parking lot on-site shall be provided in clusters of up to eight (8) spaces. Parking clusters shall be separated by a minimum four (4) foot landscaped buffer. (ii) Parking lots shall be set back at least ten (10) feet from the property line. (iii) Screening shall be required between clustered parking areas and public streets, common courtyards, and existing single-family residential. (iv) Landscaping, fencing, or walls at least three (3) feet tall shall separate parking areas and parking structures from common courtyards and public streets. 8. Cottage Orientation. a. Each cottage cluster unit shall either abut a common courtyard or shall be directly connected to the common courtyard by an ADA compliant pedestrian path, and shall meet the following standards: (i) A minimum of 50% of the cottage cluster units within a cottage cluster development shall be oriented to the common courtyard and shall: (1) Have a main entrance facing the common courtyard, as applicable. (2) Be within ten (10) feet of the common courtyard measured from the façade of the cottage cluster unit to the nearest edge of the common courtyard. (3) Be connected to the common courtyard by a pedestrian path. (ii) Cottage cluster units within twenty (20) feet of a street property line may have their entrances facing the street. (iii) Cottage cluster units not facing the common courtyard or the street, shall have their main entrances facing a pedestrian path that is directly connected to the common courtyard. [image] Figure F. Example of a Small Lot Single-Family Cluster Development. 9. Common Courtyard. a. The minimum common courtyard shall be 150 square feet per cottage cluster unit. b. The common courtyard shall be a single compact, continuous, central open space, that has a minimum width of fifteen (15) feet. c. The common courtyard shall be developed with a mix of landscaping and lawn area, recreational amenities, hard-surfaced pedestrian paths, and/or paved courtyard area, Impervious elements of the common open space shall not exceed 70 percent of the total common courtyard area. d. Pedestrian paths must be included in a common courtyard. Paths that are contiguous to a courtyard shall count toward the courtyard's minimum dimension and area. Parking areas, required setbacks, and driveways do not qualify as part of a common courtyard. 10. Community Buildings. Single-family cluster developments may include community buildings for the shared use of residents that provide space for accessory uses such as community meeting rooms, guest housing, exercise rooms, daycare, or community eating areas. Community buildings shall require a conditional use permit.

( Ord. 1754 , 6/24/2025 )

Ask a question about Buena Park law

Corpus searches the Buena Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.