§ 19.736.080 — Parking Structure
City Code, City of Buena Park, California (Includes legislation through Ord. No. 1769 adopted July 14, 2026) · Buena Park City Code § 19.736.080
Corpus is an independent public-information project, not the official City of Buena Park website. Stable reference: corpuslaw.us/code/d190f8d3-49a7-497e-a55d-35c398ef7963
§ 19.736.080: Parking Structure.
In addition to other requirements of this Division, a parking structure shall be subject to the following requirements. A. For any portion of a parking structure within 50-feet of a residential zone, openings, other than for pedestrian or vehicular access shall be visually screened on any wall which faces the residential zone. Furthermore, any ramp and the top level parking surface shall have a minimum of 5-foot high perimeter solid wall as measured from the floor of the parking surface. B. For the purpose of screen parking vehicles from public view on all other levels, there shall be a minimum of 48-inch high perimeter architectural screen or wall as measured from the finished floor, for all parking areas within the structure. 1. A parapet may count as an architectural screen if it meets the height requirement and effectively blocks the view of parked vehicles. 2. Examples of acceptable architectural screens include solid walls, perforated metal panels, decorative masonry, louvered screens, or vegetation walls, provided they are designed to complement the overall architectural style of the building and sufficiently obscure parked vehicles from public view. C. The use of materials and the architectural design for the parking structure shall be compatible with the other structures on the property. D. Suitable trees of a size and height relative to the scale and height of the structure shall be planted near and around the parking structure. E. The exterior elevations of parking structures shall be designed to minimize the use of blank concrete facades. This can be accomplished through the use of textured concrete, planters or trellises, or other architectural treatments. 1. Any driveway providing access to a parking structure shall have a minimum width of 25 feet. 2. Parked vehicles at each level in the structure shall be shielded from view of adjoining streets. 3. If a toll or fee booth is in the driveway area, the driveways on either side of the booth shall have a minimum width of 14 feet and minimum depth of 40 feet from the property line to the booth to ensure vehicles can queue without obstructing traffic. 4. The maximum length of a parking aisle without being intersected by another parking aisle or driveway shall be 300 feet. 5. All ramps shall be provided with transition zones at the top and bottom of the ramp. Ramps with a grade of 10 percent or less shall have a transition zone at least 8 feet in length. Ramps with a grade of greater than 10 percent shall have transition zones at least 12 feet in length. The grade of a transition zone shall not exceed one-half the grade of the ramp it serves. 6. Minimum lighting requirement at entrances and exits is 20 foot-candles. Minimum lighting requirement of parking areas is 1.0 foot-candles. 7. The minimum distance of entry/exit from a corner intersection is 150 feet. 8. Large illuminated signs with architectural features, such as an arch or canopy, shall be used at the entrance to emphasize the facility entry and attract patrons. 9. Drive aisles shall be designed with a minimum turning radius of 25 feet to accommodate safe maneuvering of vehicles.
( Ord. 1754 , 6/24/2025 )
Ask a question about Buena Park law
Corpus searches the Buena Park sections it holds and shows the ones that match, with their citations. Free, no sign-in.