§ 15.36.050 — California Fire Code Chapter 9 – Fire Protection and Life Safety Systems – Adopted and Amended

Municipal Code of the City of Chula Vista, California (Chula Vista Municipal Code current through Ordinance 3626, passed August 18, 2026 (municipal.codes publication, scraped 2026-11-17)) · Chula Vista Municipal Code § 15.36.050

Corpus is an independent public-information project, not the official City of Chula Vista website. Stable reference: corpuslaw.us/code/1fbb97ae-bdce-4ee2-9156-adcf2407c82c

15.36.050 California Fire Code Chapter 9 – Fire Protection and Life Safety Systems – Adopted and Amended.

California Fire Code, Chapter 9, Fire Protection and Life Safety Systems, is adopted with the following amendments: A. Chapter 9, Section 901.6.3, Records, is amended to add Section 901.6.3.2, Records reporting, to read as follows: 901.6.3.2 Records reporting. The Fire Code Official has the authority to enter into a contract/agreement with a third-party vendor for purposes of collecting, organizing, categorizing, and tracking inspection, testing, and maintenance records in accordance with the adopted California edition of NFPA 25. All inspection, testing and maintenance records shall be forwarded and made accessible to the Fire Code Official using the digital records management platform of the designated third-party as approved by the City. Paper (hard copy) reports are not permitted. Third-party vendor fees are further approved under said contract/agreement. B. Chapter 9, Section 903.2.8.1, Group R-3, is amended to add Section 903.2.8.1.1, NFPA 13-D meter size, to read as follows: 903.2.8.1.1 NFPA 13-D meter size. The minimum water meter size serving NFPA 13-D (dwelling) fire sprinkler systems shall be no less than one (1) inch in diameter. Exceptions: 1. Minimum meter size can be dependent upon hydraulic analysis, including safety factors, for second dwelling units and accessory structures to group R3 occupancies. C. Chapter 9, Section 905.4, Location of Class I standpipe hose connections, is amended to read as follows: 905.4 Location of Class I standpipe hose connections. Class I standpipe hose connections shall be provided in all of the following locations: 1. In every required interior exit stairway or exterior exit stairway, a hose connection shall be provided for each story above and below grade plane. Hose connections shall be located at intermediate floor level landings between floors or as approved by the Fire Code Official. See Section 909.20.2.3 of the California Building Code for additional provisions in smokeproof enclosures. Exception to Item 1 of 905.4 along with Item 2 through 6 shall remain in full force and effect.

Ask a question about Chula Vista law

Corpus searches the Chula Vista sections it holds and shows the ones that match, with their citations. Free, no sign-in.