15.36.270 California Fire Code – Appendices – Adopted in part and Amended.
The Appendices to the California Fire Code are adopted in part and amended as follows: A. Appendix Chapter 4, Special Detailed Requirements Based Upon Use and Occupancy, is adopted. B. Appendix B, Fire-Flow Requirements for Buildings, is adopted with the following amendments: TABLE B105.1(1). TABLE B105.1(1) REQUIRED FIRE FLOW FOR ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSESb FIRE FLOW CALCULATION AREA (square feet) | AUTOMATIC SPRINKLER SYSTEMS (Design-Standard) | MINIMUM FIRE FLOW (gallons per minute)a | FLOW DURATION (hours) FIRE FLOW CALCULATION AREA (square feet) | AUTOMATIC SPRINKLER SYSTEMS (Design-Standard) | MINIMUM FIRE FLOW (gallons per minute)a | FLOW DURATION (hours) 0-3,600 | No automatic sprinkler system | Value in Table B105.1(2) | Duration in Table B105.1(2) at the required fire-flow rate 3,601 and greater | No automatic sprinkler system | Value in Table B105.1(2) | Duration in Table B105.1(2) at the required fire-flow rate 0-3,600 | Section 903.3.1.3 of the California Fire Code or Section P2904 of the California Residential Code | Value in Table B105.1(2) | Duration in Table B105.1(2) at the required fire-flow rate 3,601 and greater | Section 903.3.1.3 of the California Fire Code or Section P2904 of the California Residential Code | Value in Table B105.1(2) | Duration in Table B105.1(2) at the required fire-flow rate Table B105.2, Required fire flow for buildings other than one- and two-family dwellings, group R-3 and R-4 buildings and townhouses, is amended to read as follows: TABLE B105.2. TABLE B105.2 REQUIRED FIRE FLOW FOR BUILDINGS OTHER THAN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSESc AUTOMATIC SPRINKLER SYSTEMS (Design-Standard) | MINIMUM FIRE-FLOW (gallons per minute)b | FLOW DURATION (hours) AUTOMATIC SPRINKLER SYSTEMS (Design-Standard) | MINIMUM FIRE-FLOW (gallons per minute)b | FLOW DURATION (hours) No automatic sprinkler system | Value in Table B105.1(2)a | Duration in Table B105.1(2) Section 903.3.1.1 of the California Fire Code | 75% of the value in Table B105.1(2)a | Duration in Table B105.1(2) at the original flow rate Section 903.3.1.2 of the California Fire Code | 75% of the value in Table B105.1(2)a | Duration in Table B105.1(2) at the original flow rate C. Appendix BB, Fire-Flow Requirements for Buildings, is adopted with the following amendment: Appendix BB, Section BB105, Fire-Flow Requirements for Buildings, is amended to read as follows: BB105.1 The minimum fire flow and flow duration for school buildings shall be as specified in Table BB105.1. Exception. A reduction in required fire flow of up to 25 percent is allowed when the building is provided with an approved automatic sprinkler system. When a reduction in fire flow is used, fire flow shall not be less than 1500 GPM. D. Appendix C, Fire Hydrant Locations and Distribution, is adopted with the following amendment: Appendix C, Table C102.1, Required number and spacing of fire hydrants – Footnotes, is amended to read as follows: TABLE C102.1 REQUIRED NUMBER AND SPACING OF FIRE HYDRANTS a. The fire code official is authorized to modify the location, number and distribution of fire hydrants based upon site-specific constraints, and hazards. All other footnotes are deleted. E. Appendix CC, Fire Hydrant Locations and Distribution, is adopted with the following amendment: Appendix CC, Table CC105.1, Number and distribution of fire hydrants – Footnotes, is amended to read as follows: TABLE CC105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS Footnotes a through e are deleted. F. Appendix H, Hazardous Materials Management Plans and Hazardous Materials Inventory Statements, is adopted. G. Appendix P, Temporary Haunted Houses, Ghost Walks and Similar Amusement Uses, is adopted. H. Appendices not listed herein are not adopted as part of this chapter.
(Ord. 3613 § 2, 2025).
Ask a question about Chula Vista law
Corpus searches the Chula Vista sections it holds and shows the ones that match, with their citations. Free, no sign-in.