Ch. 9.50 Appendix Two — Appendix Two of Chapter 9.50 CVMC
Municipal Code of the City of Chula Vista, California (Chula Vista Municipal Code current through Ordinance 3626, passed August 18, 2026 (municipal.codes publication, scraped 2026-11-17)) · Chula Vista Municipal Code § Ch. 9.50 Appendix Two
Corpus is an independent public-information project, not the official City of Chula Vista website. Stable reference: corpuslaw.us/code/07e4d6e9-198a-4b9e-8158-6ce52fc99e39
Appendix Two
MOBILEHOME PARK CODE VIOLATIONS WHICH MAY CREATE SERIOUS HEALTH, SAFETY, AND WELFARE PROBLEMS INDIVIDUAL SPACES – Exterior only A. All lots shall be numbered in a conspicuous location facing the interior roadway. [Section 1104(a)] B. Power sources and plumbing adequately supplied, supported, and protected. [Sections 1170, 1182, and 1280] C. No illegal discharge of liquid or solid wastes (CVMC 19.66.150) THE FOLLOWING APPLY TO PARK GROUNDS – NOT INDIVIDUAL SPACES PARK IN GENERAL – not individual spaces/lots PARK GROUNDS A. Clearly identify park address at street [CVMC Section 12.48.030] B. Emergency information posted in conspicuous place. [Section 1686] C. Unobstructed roadway shall be a 25 feet minimum (15 feet minimum if park constructed prior to 9-15-61). If parking is allowed on one side of roadway, minimum clearance is 32 feet, and if parking is permitted on both sides of roadway, a minimum clearance of 40 feet is required. If there is some type of curb divider, each side must be a minimum of 15 feet. [Section 1106] D. Maintain proper grading and drainage (Accumulation of water) [Section 1610(a)] E. Adequate refuse/rubbish disposal. [Section 1610 (d)] F. No illegal discharge of liquid or solid wastes (CVMC 19.66.150) PERMANENT BUILDING STRUCTURES G. Any new structures or work to have required permits [Section 1018(a)] H. Maintenance sufficient to assure minimum life and safety standards [Section 1636] I. Water heater properly installed and vented [Uniform Plumbing Code Sections 508.0, 512.1, and 608] J. Required lighting in public toilets, showers, and laundry facilities [Section 1612] K. Conformance with the California Fire Code (CFC): 1. Exit Doors (CFC 2501.8) 2. Aisles (CFC 2501.9) 3. Seating (CFC 2501.10) 4. Exit ways must be free of obstructions. [CFC 2501.11] 5. Fire extinguishers shall be maintained in good repair. [CFVC 2501.13] 6. Exits shall be identified and lighted [CFC 2501.15, 1211 and 1212] 7. Room capacity shall be posted [CFC 2501.16.1] UTILITIES L. All electrical equipment outside permanent buildings shall comply with requirements of the California Electrical Code (CEC). [Section 1134(a) and 1384] M. All overhead electrical supply and conductors and supporting structures shall comply with requirements of the California Public Utilities Commission Rules for Overhead Electrical Line Construction. [Section 1134.(b) & (c)] N. Connections adequately protected if subject to potential damage by vehicles, etc. [Sections 1228(a) and 1280] O. All electrical switches, circuit breakers, receptacles, lighting fixtures, control equipment, and metering devices located in wet places or outside of a building shall be rain-tight type equipment. [Section 1170(a)] P. Sufficient space around electrical equipment to permit ready and safe operation. [Section 1646(a)(b)] Unless otherwise noted, all Section references are found in Title 25 of the California Code of Regulations. The city of Chula Vista shall provide a copy of all referenced code sections to all park owners and/or their agents. Copies of these referenced code sections shall be maintained at all times at the on-site Manager’s office and may be viewed during normal business hours by any and all residents.
Ask a question about Chula Vista law
Corpus searches the Chula Vista sections it holds and shows the ones that match, with their citations. Free, no sign-in.
