§ 9.34.090 — General provisions for all signs
Municipal Code, City of Clovis, California (code date 2026-08-17) · Clovis Municipal Code § 9.34.090
Corpus is an independent public-information project, not the official City of Clovis website. Stable reference: corpuslaw.us/code/aa833f71-c2c4-4473-b119-b0e9cfc29472
§ 9.34.090: General provisions for all signs.
A. Approval required. No sign shall be altered, constructed, displayed, or maintained within the City except in compliance with a permit approved in compliance with this chapter, unless the sign is specifically exempted from the permit requirements. Signs may be erected and maintained in the zoning district where applicable structures are allowed with an approved permit. B. Compliance with other codes. The erection or placement of all signs shall meet the requirements of the State Public Utilities Commission, the Underwriter’s Laboratory, the Uniform Sign Code as adopted by the City, the regulations of the Department, and all other relevant Federal, State, and local laws and regulations. C. Shopping center signs. 1. The sign program for shopping centers shall be approved with the site plan review in compliance with Chapter 56 of this title. 2. The design criteria for all signs to be located within a shopping center or a mall-type development shall be approved by the Director, before any individual sign permit application for the development is reviewed by the Building Inspection Division. 3. The review shall ensure that signs located within a shopping center are harmonious and of compatible design. 4. Shopping center signs located within the P-C-C (Planned Commercial Center) or the U-C (Urban Center) District shall be reviewed as part of the Zoning Map amendment process, in compliance with Chapter 86 of this title (Amendments). D. Lighting for exterior illuminated signs. Lighting for exterior illuminated signs shall not create a hazardous glare for pedestrians or vehicles, either in a public street or on any private premises. Each sign shall be designed so that illumination does not exceed ten (10) candlepower at a distance of ten feet (10'), measured from the base of the sign. 1. Blinking. Signs shall not have blinking, flashing, or fluttering lights or other illuminating devices that have a changing light brightness, color, or intensity. 2. Colored lights. Colored lights shall not be used at a location or in a manner so as to be confused or construed as traffic control devices. 3. Energy efficient fixtures. Light sources shall utilize energy efficient fixtures to the greatest extent possible. 4. Not a hazard. Neither the direct nor reflected light from primary light sources shall create a hazard to operators of motor vehicles. 5. Reflective bulbs. Reflective-type bulbs and incandescent lamps that exceed fifteen (15) watts shall not be used on the exterior surface of signs so as to expose the face of the bulb or lamp to public rights-of-way or adjacent structures and properties. 6. Light-emitting diode (LED) signs. LED lighting shall not exceed 10 candlepower at a distance of ten feet (10'), measured from the base of the sign. 7. Sign separation. Illuminated freestanding signs shall not be placed within fifty feet (50') of an adjacent residential property. E. Screening light sources. 1. Whenever an illuminated advertising device is allowed, every part of its light source shall be concealed from view, and the light shall not travel from the light sources straight to the viewer’s eye, but instead shall be visible only from a reflecting or diffusing surface. 2. Exemptions from this requirement shall be neon tubing which conforms to subsection D of this section (Lighting for exterior illuminated signs), and is counted in the total permanent sign area. 3. As used in this subsection, “light source” shall mean a bulb or tube from which light is emitted when the bulb or tube is activated (electronically or otherwise), including incandescent filament bulbs, electric discharge bulbs, and fluorescent tubes. F. Measurement of wall sign areas. 1. Wall signs consisting of one or two (2) lines of copy. a. Wall signs consisting of one or two (2) lines of copy painted on or attached to a structure wall where the portion of the wall behind the sign is the same color as the rest of the wall and does not serve as a frame area shall be measured by the smallest regular geometric shape not exceeding eight (8) sides which encompasses the emblem, symbol, or words composing the sign. (See subsection (F)(6) of this section (How to further measure wall sign area).) b. Areas between words in a line and between lines shall not be measured as long as they are reasonably spaced. (See subsection (F)(6) of this section (How to further measure wall sign area).) 2. Other wall signs. Three (3) lines or more of copy or nonlinear arrangement shall be measured as that area which can be enclosed within the smallest regular geometric shape not exceeding eight (8) sides which encompasses the total message, including the open space between cutout figures, letters, objects, panels, or symbols. (See subsection (F)(6) of this section (How to further measure wall sign area).) 3. Signs which are framed or have distinguishing color background. Signs which are framed or have distinguishing color background shall be measured by taking the entire area of the sign and background, including the framing surface. 4. Multiple face signs. a. The area of all faces shall be added together to determine the total sign area. b. However, a double-faced sign may be erected having the allowed sign area on each side of the sign; provided, the maximum dimension between the two (2) faces shall not exceed twenty-four inches (24"). c. Both faces of a double-faced sign which exceeds twenty-four inches (24") between the two (2) faces shall be counted together to determine the total sign area. 5. Neon tube lighting (or LED lighting). Illuminated neon tubing or LED rope lighting when outlining portions of structures or windows shall be deemed to have a minimum width of at least six inches (6") in the calculation of sign area. Where an area bordered by lighting is substantially a closed geometric shape, all the area enclosed shall be considered the sign area. 6. How to further measure wall sign area. The surface area of a sign shall be calculated by enclosing the extreme limits of all emblem, logo, representation, writing, or other display within a single continuous perimeter composed of squares or rectangles with no more than eight (8) lines. [image] FIGURE 3-11 SIGN AREA MEASUREMENT a. Framework. Supporting framework or bracing that is clearly incidental to the display itself shall not be computed as sign area. b. Vertical plane. Where a sign consists of one or more three-dimensional objects (e.g., balls, clusters of objects, cubes, sculpture or statue-like trade-marks), the sign area shall be measured as the total surface area of the object(s). c. Time and temperature. For signs that incorporate time and temperature devices, the area devoted to the time and temperature devices shall be included in the total allowable area of the sign. G. Measurement of sign height. See Section 9.34.100(B)(3) (Measurement of sign height). H. Sign copy. The City does not regulate the message content (copy) of signs; however, the following are principles of copy design and layout that can enhance the readability and attractiveness of signs. Copy design and layout consistent with these principles is strongly encouraged, but not required: 1. Sign copy should relate only to the name and/or nature of the business or commercial center. 2. Information should be conveyed briefly or by logo, symbol, or other graphic manner. The intent should be to increase the readability of the sign and thereby enhance the identity of the business. 3. Freestanding signs should contain the street address of the parcel or the range of addresses for a multi-tenant center. The address(es) shall not be included in the total allowable area of the sign.
(§ 2, Ord. 14-13 , eff. October 8, 2014 )
Ask a question about Clovis law
Corpus searches the Clovis sections it holds and shows the ones that match, with their citations. Free, no sign-in.
