§ 9.40.030 — Accessory uses and structures
Municipal Code, City of Clovis, California (code date 2026-08-17) · Clovis Municipal Code § 9.40.030
Corpus is an independent public-information project, not the official City of Clovis website. Stable reference: corpuslaw.us/code/8dcdde03-37dd-49a3-aac4-ea2d628113fe
§ 9.40.030: Accessory uses and structures.
This section provides standards for accessory uses and structures allowed in the applicable residential zoning districts (see Section 9.10.020 (Residential district land uses and permit requirements)), subject to the following criteria and standards: A. Definition. Accessory residential uses and structures include any that are: 1. Customarily related to a residence, including garages, greenhouses, storage sheds, studios, above ground swimming pools/spas, and workshops; 2. Not counted as or containing a living area; and 3. A minimum of sixty-four (64) square feet in gross floor area. B. Relationship of accessory use to the main use. Accessory uses and structures shall be incidental to and not alter the residential character of the subject site. C. Attached structures. An attached accessory structure shall: 1. Be compatible with and made structurally a part of the main structure (e.g., share a common wall with the main structure, rely partially on the main structure for structural support, or be attached to the main structure); 2. Comply with the requirements of this Development Code applicable to the main structure, including coverage, height, and setbacks; and 3. Be compatible with the materials and colors of the main structure. D. Detached structures. 1. Detached accessory structures shall require a rear yard encroachment permit if located in the rear setback area. The accessory structure cannot exceed the allowable site coverage for the zone district. A building permit is required for any structure over one hundred twenty (120) square feet in size. 2. Detached accessory structures shall: a. Not exceed a height of twelve feet (12') when located in rear yard setback; with additional height subject to approval of an administrative use permit in compliance with Chapter 62 of this title, not to exceed the height limit of the applicable zoning district; b. Where an accessory building, either attached to or detached from the main building, is less than six feet (6') from such main building, such accessory building shall be deemed a main building for the purposes of applying the property development standards. The required setbacks and maximum height of the main structure shall apply to an accessory structure located less than six feet (6') from such main building. c. Be compatible with the materials and colors of the main structure; and d. Shall comply with building and fire code separation standards. E. Setback and height requirements. Setbacks shall be in compliance with Table 4-1 (Required Setbacks – Accessory Residential Uses and Structures). 1. Maximum height shall be as per the following and Figure 4-1: a. Within allowable building area: same height as permitted for the main structure. b. Within rear yard setback area: twelve-foot (12') overall height. With an approved administrative use permit, accessory buildings in excess of twelve feet (12') in height with a plate height no greater than twelve feet (12'). Freestanding fireplace units shall be a maximum of twelve feet (12') to the top of the flue. [image] FIGURE 4-1 SETBACKS TABLE 4-1 REQUIRED SETBACKS ACCESSORY RESIDENTIAL USES AND STRUCTURES ACCESSORY STRUCTURE | TYPE OF SETBACK (1) | REQUIRED SETBACK SINGLE-FAMILY DETACHED HOMES Garage, gazebo, greenhouse, lightweight frame structure, patio cover, storage shed, workshop (2) | Front | As required for the main structure Sides, street side, reverse corner side yard | As required for the main structure for structures greater than 120 square feet. No requirement for structures of 120 square feet or less in side setbacks. (5) Rear | As required for the main structure, or 5-foot minimum with an approved rear yard encroachment for structure greater than 120 square feet. No requirement for structures of 120 square feet or less in rear setback. Between detached structures | As required for the main structure, 5-foot minimum Fish pond, waterfalls, outdoor play equipment, spa, pool slides, swimming pool | Front | 20 feet Sides | 5 feet Street side | 10 feet Rear | 5 feet Reverse corner side yard | 15 feet Stationary barbecue, outdoor fire pit/fireplaces | Front | 10 feet Sides | 3 feet Street side | 10 feet (3) Rear | 3 feet Small cargo containers (aka pods and seatrains) | Front | 10 feet (4) Sides | 3 feet Street side | 10 feet (3) Rear | 3 feet Air conditioning equipment, diving board, emergency generator, pool and spa equipment | Front | 20 feet Sides | 3 feet Street side | 10 feet Rear | 3 feet MULTIFAMILY, ATTACHED/DETACHED Garage, gazebo, greenhouse, lightweight frame structure, patio cover, storage shed, workshop | Sides, street side | As required for main structure Rear | As required for main structure Small cargo containers (aka pods and seatrains) | Front, sides, street side, and rear | As required for main structure (4) Air conditioning equipment, fish pond, outdoor play equipment, pool and spa equipment, spa, swimming pool | Front, sides, street side, and rear | As required for main structure Stationary barbecue, fire pit | Front | 10 feet Side | 3 feet Street side | 10 feet Rear | 3 feet Notes: (1) | Where a parcel is situated so that the front, side, or rear property lines are not readily determinable, required setbacks shall be established by the Director. (2) | Garages on corner or reverse corner lots shall not be built closer than twenty feet (20') to any street side property line. (3) | Reverse corner lots shall maintain a minimum street (e.g., front or street side) setback of fifteen feet (15'), or as required by the subject zoning district. (4) | Shall comply with Section 9.40.060. (5) | Accessory structures over one hundred twenty (120) square feet may be located within three feet (3') of a side yard when the front face is more than eighty-five feet (85') from the front property line. F. Lightweight frame structures. This subsection provides standards for accessory lightweight frame structures allowed in the applicable residential zoning districts (see Section 9.10.020 (Residential district land uses and permit requirements)), subject to the following criteria and standards: 1. A lightweight frame structure located in any residential zoning district shall meet all required front, side, and rear setback requirements for the main structure. 2. A lightweight frame structure in excess of one hundred twenty (120) square feet of roof area may encroach into the rear setback but only with a rear yard encroachment permit, provided: a. The structure is at least six feet (6') away from the main structure; b. The structure shall not be located in the required side setback for the zoning district in which it is located; c. Space equal to the reduction (e.g., the amount of the rear yard encroachment) shall be provided elsewhere on the subject parcel, exclusive of the required yard area. The replacement space shall be equal to the total square footage encroaching into the rear yard setback and shall be located in a manner suitable for general use by the occupants; d. The standards for issuance of a rear yard encroachment permit are satisfied; and e. In no event shall the standards for issuance of a rear yard encroachment permit be considered satisfied unless the applicant first submits, together with the required site plan, written statements, or other evidence deemed satisfactory to the Director, that all adjoining property owners have consented to the requested encroachment. 3. A detached lightweight frame structure of less than one hundred twenty (120) square feet of roof area may encroach into a side or rear setback, and shall be allowed up to the property line. 4. Building permit requirements. Lightweight frame structures shall be subject to the California Building Code requirements. a. A detached lightweight frame structure of any size shall require the issuance of a building permit. 5. In no event shall any lightweight frame structure result in the maximum lot coverage restrictions for the subject zoning district being exceeded. 6. In no event shall any lightweight frame structure exceed twelve feet (12') in overall height or seven feet (7') in overall height within three feet (3') of a property line. 7. Each application shall be reviewed for compliance with the requirements of Chapter 1 of Title 8 and the State Building Standards Code, Title 24, Chapter 31, Division II (Membrane Structures).
(§ 2, Ord. 14-13 , eff. October 8, 2014 ; § 1 (Att. 3), Ord. 18-19 , eff. September 5, 2018 ; § 1(2) (Atts. 1, 2), Ord. 20-18 , eff. February 3, 2021 ; § 1(2) (Att. A), Ord. 23-05 , eff. August 9, 2023 )
Ask a question about Clovis law
Corpus searches the Clovis sections it holds and shows the ones that match, with their citations. Free, no sign-in.
