15.75.170 Standards of construction.

In all areas of special flood hazards the following standards are required: (a) Anchoring. All new construction and substantial improvements of structures, including manufactured homes, shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. (b) Construction Materials and Methods. All new construction and substantial improvements of structures, including manufactured homes, shall be constructed: (1) With flood resistant materials, and utility equipment resistant to flood damage for areas below the base flood elevation; (2) Using methods and practices that minimize flood damage; (3) With electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities elevated to, or above, the BFE or depth number specified on the FIRM; and (4) Within Zones AH or AO, so that there are adequate drainage paths around structures on slopes to guide flood waters around and away from proposed structures. (c) Elevation and Floodproofing. (1) Residential construction. All new construction or substantial improvements of residential structures shall have the lowest floor, including basement: a. In AE, AH, A1-30 Zones, elevated to 1 foot or more above the base flood elevation. b. In an AO zone, elevated above the highest adjacent grade to a height equal to or exceeding 1 foot above the depth number specified in feet on the FIRM, or elevated at least 2 feet above the highest adjacent grade if no depth number is specified. c. In an A zone, without BFE’s specified on the FIRM [unnumbered A zone], where the BFE’s have been determined pursuant to subsection 15.75.140(c), elevated as required in subsection 15.75.170(c)(1)a. d. In an A zone, without BFE’s specified on the FIRM [unnumbered A zone], where the BFE’s have not otherwise been determined, the following requirements shall apply: 1. Single parcels – Elevate the lowest floor of any residential structure to no less than two feet above natural grade when base flood elevation is not established. 2. Multiple parcels (five or more) – All proposals shall establish the 100-year base flood elevation before the first consideration of any plan or permit for construction or development of the parcels. The city may require standards for subdivisions in excess of those identified elsewhere in this chapter. Upon the completion of the forms for the structure’s foundation, and prior to pouring the foundation, the elevation of the lowest flood, including basement, shall be certified by a registered civil engineer or licensed land surveyor, and verified by the building division to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. Upon the completion of the structure, the elevation of the lowest floor, including basement, shall be certified by a registered civil engineer or licensed land surveyor, and verified by the building division to be properly elevated. Such certification and verification shall be provided to the Floodplain Administrator. (2) Nonresidential construction. All new construction or substantial improvements of nonresidential structures shall either be elevated to conform with subsection 15.75.170(c)(1) or: a. Be floodproofed, together with attendant utility and sanitary facilities, below the elevation recommended under subsection 15.75.170(c)(1), so that the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and c. Be certified by a registered civil engineer or architect that the standards of subsections 15.75.170(c)(2)a and 15.75.170(c)(2)b are satisfied. Such certification shall be provided to the Floodplain Administrator. (3) Floodproofing. Nonresidential construction shall either be elevated in conformance with subsections 15.75.170(c)(1) or 15.75.170(c)(2) or, together with attendant utility and sanitary facilities, be floodproofed to the base flood elevation. Examples of floodproofing include, but are not limited to: a. Installation of watertight doors, bulkheads, and shutters; b. Reinforcement of walls to resist water pressure; c. Use of paints, membranes, or mortars to reduce seepage through walls; d. Addition of mass or weight to structure to resist flotation; e. Armor protection of all fill materials from scour and/or erosion; f. Certification provided to the city by a registered professional engineer or architect that the standards of this subsection are satisfied. g. For all new construction and substantial improvements, fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement shall either be certified by a registered professional engineer or architect or shall meet or exceed the following minimum criteria: A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (4) Flood openings. All new construction and substantial improvements of structures with fully enclosed areas below the lowest floor (excluding basements) that are usable solely for parking of vehicles, building access or storage, and which are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement shall meet the following minimum criteria: a. For non-engineered openings: 1. Have a minimum of two openings on different sides having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above grade; 3. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwater; and 4. Buildings with more than one enclosed area shall have openings on exterior walls for each area to allow flood water to directly enter; or b. Be certified by a registered civil engineer or architect. (5) Manufactured homes. See section 15.75.200. (6) Garages and low cost accessory structures. a. Attached garages. 1. A garage attached to a residential structure, constructed with the garage floor slab below the BFE, shall be designed to allow for the automatic entry of flood waters. See subsection 15.75.170(c)(4). Areas of the garage below the BFE shall be constructed with flood resistant materials. See subsection 15.75.170(b). 2. A garage attached to a nonresidential structure shall meet the above requirements or be dry floodproofed. For guidance on below grade parking areas, see FEMA Technical Bulletin TB 5.25.030. b. Detached garages and accessory structures. 1. “Accessory structures” used solely for parking (2 car detached garages or smaller) or limited storage (small, low-cost sheds), as defined in Article II of this chapter, may be constructed such that its floor is below the base flood elevation (BFE), provided the structure is designed and constructed in accordance with the following requirements: i. Use of the accessory structure shall be limited to parking or limited storage; ii. The portions of the accessory structure located below the BFE shall be built using flood-resistant materials; iii. The accessory structure shall be adequately anchored to prevent flotation, collapse and lateral movement; iv. Any mechanical and utility equipment in the accessory structure shall be elevated or floodproofed to or above the BFE; v. The accessory structure shall comply with floodplain encroachment provisions in section 15.75.210; and vi. The accessory structure shall be designed to allow for the automatic entry of flood waters in accordance with subsection 15.75.170(c)(4). 2. Detached garages and accessory structures not meeting the above standards shall be constructed in accordance with all applicable standards in section 15.75.170. (7) Crawl Space Construction. This subsection applies to buildings with crawl spaces up to 2 feet below grade. Below-grade crawl space construction in accordance with the requirements listed below will not be considered basements. a. The building shall be designed and adequately anchored to resist flotation, collapse, and lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. Crawl space construction is not allowed in areas with flood velocities greater than 5 feet per second unless the design is reviewed by a qualified design professional, such as a registered civil engineer; b. The crawl space is an enclosed area below the BFE and, as such, shall have openings that equalize hydrostatic pressures by allowing for the automatic entry and exit of floodwaters. For guidance on flood openings, see FEMA Technical Bulletin TB 1-08; c. Portions of the building below the BFE shall be constructed with materials resistant to flood damage. This includes not only the foundation walls of the crawl space used to elevate the building, but also any joists, insulation, or other materials that extend below the BFE; and d. Any building utility systems within the crawl space shall be elevated above BFE or designed so that floodwaters cannot enter or accumulate within the system components during flood conditions. e. Requirements for all below-grade crawl space construction, in addition to the above requirements, to include the following: 1. The interior grade of a crawl space below the BFE shall not be more than 2 feet below the lowest adjacent exterior grade (LAG), shown as D in figure 3 of Technical Bulletin TB 11-01; 2. The height of the below-grade crawl space, measured from the interior grade of the crawl space to the top of the crawl space foundation wall shall not exceed 4 feet (shown as L in figure 3 of Technical Bulletin TB 11-01) at any point; 3. There shall be an adequate drainage system that removes floodwaters from the interior area of the crawl space within a reasonable period of time after a flood event, not to exceed 72 hours; and 4. The velocity of floodwaters at the site should not exceed 5 feet per second for any crawl space. For velocities in excess of 5 feet per second, other foundation types shall be used. (8) Standards for storage of materials and equipment. a. The storage or processing of materials that are in time of flooding, buoyant, flammable, explosive, or could be injurious to human, animal, or plant life is prohibited. b. Storage of other material or equipment may be allowed if not subject to major damage by floods and firmly anchored to prevent flotation or if readily removable from the area within the time available after flood warning. (Code 2002, § 34-91. Ord. No. 10-1)

Cross references: Buildings and building regulations, Title 15; health and sanitation, Title 8; manufactured homes, mobile homes, and trailers, Ch. 15.105; streets, sidewalks, and other public places, Title 12; subdivisions, Title 17; utilities, Title 13; zoning, Title 18.

Ask a question about Concord law

Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.