15.85.110 Residential security provisions.

(a) Purpose. The purpose of this section is to set forth minimum standards of construction for resistance to unlawful entry to the residential structures located in the city. (b) Alternatives. Nothing contained in this article shall be deemed to prohibit the use of alternate materials, devices, or measures when such alternate provisions are deemed by the Building Official as providing equivalent security. (c) Tests. (1) Sliding glass doors. Panels shall be closed and locked. Tests shall be performed in the following order: a. Test A. With the panels in the normal position, a concentrated load of 300 pounds shall be applied separately to each vertical pull stile incorporating a locking device at a point on the stile within six inches of the locking device, in the direction parallel to the plane of glass that would tend to open the door; b. Test B. Repeat Test A while simultaneously adding a concentrated load of 150 pounds to the same area of the same stile in a direction perpendicular to the plane of glass toward the interior side of the door; c. Test C. Repeat Test B with the 150-pound force in the reversed direction toward the exterior side of the door; d. Tests D, E, and F. Repeat Tests A, B, and C with the movable panel lifted upwards to its full limit within the confines of the door frame. (2) Sliding glass windows. Sash shall be closed and locked. Tests shall be performed in the following order: a. Test A. With the sliding sash in the normal position, a concentrated load of 150 pounds shall be applied separately to each sash member within six inches of the locking device in the direction parallel to the plane of glass that would tend to open the window; b. Test B. Repeat Test A while simultaneously adding a concentrated load of 75 pounds to the same area of same sash member in the direction perpendicular to the plane of glass toward the interior side of the window; c. Test C. Repeat Test B with the 75 pounds force in the reversed direction toward the exterior side of the window; d. Tests D, E, and F. Repeat Tests A, B, and C with the movable sash lifted upwards to its full limit within the confines of the window frame. (3) Testing agency. All tests shall be performed by an approved independent testing agency. Written reports shall be submitted to the Building Official. (d) Doors--General. A door forming a part of the enclosure of a dwelling unit shall be of solid core construction, installed and secured as set forth in subsections (e), (f), and (g), when such door is accessible from a street, highway, yard, court, passageway, corridor, balcony, patio, breezeway, private garage, portion of the building which is available for use by the public or other tenants, or similar area. A door enclosing a private garage with an interior opening leading directly to a dwelling unit shall also comply with said subsections (e), (f), and (g) of this section. (e) Doors--Swing doors. (1) A single swing door, the active leaf of a pair of doors, and the bottom leaf of dutch doors shall be equipped with a deadbolt with a minimum throw of one inch and a deadlocking latch. Deadbolts shall contain hardened inserts, or equivalent, so as to repel cutting tool attack. The lock or locks shall be key operated from the exterior side of the door and engaged or disengaged from the interior side of the door by a device not requiring a key or special knowledge or effort. (2) Flushbolts with a minimum throw of five-eighths inch shall be provided at the head and foot (floor and ceiling) of the inactive leaf of double doors, and at the top and bottom of the upper leaf of dutch doors. (3) Door stops on wooden jambs for in-swing doors shall be of one-piece construction with the jamb or joined by a rabbet. (4) Nonremovable pins or interlocking stud-type hinges shall be used in pin-type hinges which are accessible from the outside when the door is closed. (5) Cylinder guards shall be installed on all mortise or rim-type cylinder locks whenever the cylinder projects beyond the face of the door or is otherwise accessible to gripping tools. (f) Doors--Sliding glass. (1) Sliding glass doors shall be equipped with locking devices and shall be so installed that, when subject to tests specified in subsection (c), they remain intact and engaged. Movable panels shall not be rendered easily openable or removable from the frame during or after the tests. (2) Cylinder guards shall be installed on all mortise or rim-type cylinder locks which project beyond the face of the door or is otherwise accessible to gripping tools. (g) Doors--Overhead and sliding. (1) Metal or wooden overhead and sliding doors shall be secured with a cylinder lock, padlock, with a hardened steel shackle, metal slide bar, bolt, or equivalent on the inside when not otherwise locked by electric power operation. In the event that this type door provides the only entrance to a garage, the cylinder lock or padlock may be on the outside. (2) Cylinder guards shall be installed on all mortise or rim-type cylinder locks which project beyond the face of the door or is otherwise accessible to gripping tools. (h) Windows--General. A window, skylight, or other light forming a part of the enclosure of a dwelling unit shall be constructed, installed, and secured as set forth in subsection (i) when such window, skylight, or light is not more than 12 feet above the grade of a street, highway, yard, court, passageway, corridor, balcony, patio, breezeway, private garage, portion of the building which is available for use by the public or other tenants, or similar area. A window enclosing a private garage with an interior opening leading directly to a dwelling unit shall also comply with said subsection (i). (i) Windows--Locking devices. (1) Sliding glass windows shall be provided with locking devices that, when subjected to the tests specified in subsection (c), remain intact and engaged. (2) Movable panels shall not be rendered easily openable or removable from the frame during or after the tests. (3) Other openable windows shall be provided with substantial locking devices which the Building Official finds render the building as secure as the devices required by this section. (4) Louvered windows, except those above the first story, shall not be permitted. (j) Open parking lots. Open parking lots, including lots having carports, providing more than ten parking spaces shall be provided with a maintained minimum of three horizontal footcandles of light on the parking surface during hours of darkness. (Code 1965, § 3930; Code 2002, § 14-471. Ord. No. 919; Ord. No. 83-15)

Exception: Window openings required by the building code for access by the Fire Department shall be protected by a material approved by the Fire Department.

Ask a question about Concord law

Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.