§ 18.100.040 — Development standards
Concord Municipal Code (Current through Ordinance 26-2, passed September 8, 2026) · Concord Municipal Code § 18.100.040
Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/ecdae4a2-c035-4eb3-ad2a-5cf90bc1eb5f
18.100.040 Development standards.
The following development standards are set forth in the ALUCP and shall apply to all development within the airport influence area and the safety zones as specified below. Where a conflict exists between the development standards herein and the regulations of the base zoning district, the more restrictive shall apply. A. Noise Compatibility. New development within the airport influence area shall be evaluated for compatibility with noise standards pursuant to the ALUCP. B. Safety Compatibility. New development within the safety zones (See ALUCP Safety Zones, Figure 3C) shall meet the following criteria: 1. Safety Zone 1. a. No new structures are permitted other than aeronautical facilities as determined by FAA criteria. b. Storage of fuel and other hazardous materials is prohibited. 2. Safety Zone 2. a. Land uses shall be limited to a maximum of 30 people per acre or one person per 500 square feet of gross building floor area, except that hotels, restaurants, shopping centers, theaters, and other places of public assembly may be acceptable with incorporation of the identified risk-reduction design features (see subsection (B)(5) of this section). b. Buildings shall have no more than two habitable floors above ground. c. Residences, K-12 schools, day care centers, hospitals, and nursing homes are specifically prohibited. d. Above-ground bulk storage of hazardous materials is prohibited with the exception of up to 2,000 gallons of non-aviation flammable materials. 3. Safety Zone 3. a. Land uses shall be limited to a maximum of 125 people per acre, except that fast food restaurants, major shopping centers, theaters, and other places of public assembly may be acceptable with incorporation of the identified risk-reduction design features (see subsection (B)(5) of this section). b. Buildings shall have no more than three habitable floors above ground. However, if a building is proposed to have more than two habitable floors above ground, the project shall provide a disaster management plan to facilitate the rapid evacuation of building occupants in the event of an aircraft accident involving the building. c. Residences, K-12 schools, hospitals, and nursing homes are specifically prohibited. d. Above-ground storage of more than 2,000 gallons of fuel or other hazardous materials is prohibited. 4. Safety Zone 4. a. Land use intensity is not limited, except buildings shall have no more than four habitable floors above ground. b. Above-ground storage of more than 2,000 gallons of fuel or other hazardous materials is prohibited in existing or planned residential or commercial areas. 5. Risk-reduction design features (see ALUCP, Risk Reduction Design Feature Policies 4.2.4 and 5.3.6). Subject to ALUC review as prescribed in CDC 18.100.030, higher intensity uses up to 45 people per acre for Safety Zone 2 and 250 people per acre for Safety Zone 3 may be permitted for buildings that incorporate special risk-reduction design features, such as: a. Use of concrete walls; b. Limited number and size of windows; c. Upgraded building roof strength; d. Avoidance of skylights; e. Fire sprinkler system enhancements; f. Single-story building design; and g. Increased number of emergency exits. C. Airspace Protection Criteria. (See ALUCP, Airspace Protection Surfaces, Figure 3D.) 1. Height Limitations. New development within the airport influence area that exceeds 45 feet in height shall be referred to the ALUC for a consistency determination with Federal Aviation Regulations (FAR) Part 77 and Terminal Instrument Procedures (TERPS) criteria. 2. Height Exception Overlay Zones 1 and 1*. a. Height Exception Overlay Zone 1. Structures having a height up to 279 feet above mean sea level (approximately 250 feet above ground level) are permitted. b. Height Exception Overlay Zone 1* (the area up to 100 feet west of Overlay Zone 1). Proposed structures are permitted to have a height equal to the lower of structures within the westernmost 400 feet of Height Exception Overlay Zone 1; or 279 feet above mean sea level. [Ord. 12-4. DC 2012 § 122-248].
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.
