18.205.100 Development standards.
A. Generally Applicable Development Standards. All new wireless facilities and substantial changes to existing wireless facilities not covered under Section 6409 must conform to the generally applicable development standards in this subsection (A). 1. Concealment. Wireless facilities must incorporate concealment elements, measures and techniques that blend the equipment and other improvements into the natural and/or built environment in a manner consistent and/or compatible with the uses germane to the underlying zoning district and existing in the immediate vicinity. 2. Overall Height. Wireless facilities may not exceed the applicable height limit for structures in the applicable zoning district. 3. Setbacks. Wireless facilities may not encroach into any applicable setback for structures in the subject zoning district. 4. Noise. Wireless facilities and all accessory equipment and transmission equipment must comply with all noise regulations, which includes without limitation CDC 18.150.130(O) (Noise) and the general plan, and shall not exceed, either individually or cumulatively, the applicable ambient noise limit in the subject zoning district. The approval authority may require the applicant to incorporate appropriate noise-baffling materials and/or strategies whenever necessary to avoid any ambient noise from equipment reasonably likely to exceed the applicable limit. 5. Landscaping. In accordance with Chapters 18.165 (Landscaping) and 18.170 CDC (Water Efficient Landscaping), all wireless facilities proposed to be placed in a landscaped area must include landscape features and a landscape maintenance plan prepared by a California-licensed landscape architect, or other qualified professional. The approval authority may require additional landscape features to screen the wireless facility from public view, avoid or mitigate potential adverse impacts on adjacent properties or otherwise enhance the concealment required under this chapter. All landscape features must be planted and maintained using best practice methods. The approval authority may require that all plants proposed or required under this chapter must be native and/or drought-resistant. 6. Site Security Measures. Wireless facilities may incorporate reasonable and appropriate site security measures, such as fences, walls and anti-climbing devices, to prevent unauthorized access, theft or vandalism. Site security measures must be designed to enhance concealment to the maximum extent possible, such as installing equipment within an enclosure designed to mimic a trash-can corral rather than within a chain link fence. The approval authority may require additional concealment elements as the approval authority finds necessary to blend the security measures and other improvements into the natural and/or built environment. The approval authority shall not approve barbed wire, razor ribbon, electrified fences or any similar security measures. 7. Backup Power Sources. The approval authority may approve permanent backup power sources and/or generators on a case-by-case basis. The city strongly disfavors backup power sources mounted on the ground or on poles within the public rights-of-way. The approval authority shall not approve any diesel generators or other similarly noisy or noxious generators in or within 250 feet from any residence; provided, however, the approval authority may approve sockets or other connections used for temporary backup generators. 8. Lights. Wireless facilities may not include exterior lights other than (a) as may be required under FAA, FCC or other applicable governmental regulations; and (b) timed or motion-sensitive lights for security and/or worker safety. All exterior lights permitted or required to be installed must be installed in locations and within enclosures that mitigate illumination impacts on other properties to the maximum extent feasible. 9. Signage – Advertisements. All wireless facilities must include signage that accurately identifies the equipment owner/operator, the owner/operator’s site name or identification number and a toll-free number to the owner/operator’s network operations center. Wireless facilities may not bear any other signage or advertisements unless expressly approved by the city, required by law or recommended under FCC or other United States governmental agencies for compliance with RF emissions regulations. 10. Future Collocations and Equipment. To the extent feasible and aesthetically desirable, all new wireless facilities should be designed and sited in a manner that accommodates future collocations and equipment installations that can be integrated into the proposed wireless facility or its associated structures with no or negligible visual changes to the outward appearance. 11. Utilities. All cables and connectors for telephone, primary electric and other similar utilities must be routed underground to the extent feasible in conduits large enough to accommodate future collocated wireless facilities. Meters, panels, disconnect switches and other associated improvements must be placed in inconspicuous locations to the extent possible. The approval authority shall not approve new overhead utility lines or service drops merely because compliance with the undergrounding requirements would increase the project cost. 12. Compliance with Laws. All wireless facilities must be designed and sited in compliance with all applicable federal, state and local laws, regulations, rules, restrictions and conditions, which include without limitation the California Building Standards Code, general plan and any applicable specific plan, the Concord Municipal Code and any conditions or restrictions in any permit or other governmental approval issued by any public agency with jurisdiction over the project. B. Development Standards for Specific Types of Wireless Facilities. In addition to the requirements in subsection (A) of this section, all new and substantially changed wireless facilities not covered under Section 6409 must conform to the applicable facility-specific development standards adopted by the city council. The city council shall adopt such standards following a public hearing conducted pursuant to the requirements of the Concord Municipal Code. The facility-specific development standards may include without limitation standards for freestanding facilities, building-mounted facilities and/or facilities located in the public rights-of-way. C. Design Guidelines. The director may develop and from time to time amend design guidelines, consistent with the generally applicable development standards and any development standards for specific types of wireless facilities, to clarify the aesthetic goals and standards in this chapter for city staff, applicants and the public. Any design guidelines for facilities in the public rights-of-way will be subject to approval by the public works director. In the event that a conflict arises between the development standards adopted under subsections (A) and (B) of this section and the design guidelines adopted under this subsection (C), the development standards adopted under subsections (A) and (B) of this section shall control. [Ord. 17-11 § 3 (Exh. 1)].
Prior legislation: DC 2012 §§ 122-664 – 122-677; Ords. 12-4 and 12-5.
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.