§ 18.45.030 — Table 18.45.030 – Downtown districts – Development standards
Concord Municipal Code (Current through Ordinance 26-2, passed September 8, 2026) · Concord Municipal Code § 18.45.030
Corpus is an independent public-information project, not the official City of Concord website. Stable reference: corpuslaw.us/code/e68bd63d-7ca4-4d24-a852-017f1ac984c2
18.45.030 Table 18.45.030 – Downtown districts – Development standards.
Subdivisions, new uses and structures, and alterations to existing uses and structures shall be designed, constructed, and established in compliance with the requirements specified in Table 18.45.030. Additional requirements may apply pursuant to Division IV (Development Standards) and Division V (Standards for Specific Uses) of this title. Table 18.45.030 Downtown Districts Development Standards(1) | Standards | DP(4) | DMX(4) | WMX | Additional Standards | Density (du/net acre) minimum/maximum | 33 – 100 du/net acre | 33 – 100 du/net acre | NA | | Floor Area Ratio (FAR) minimum | 0.75 | 1.00 | – | | Floor Area Ratio (FAR) maximum (4, 5) | 4.0 | 6.0 | 4.0 | | Lot Area (square feet) minimum | 5,000 | 10,000 | 25,000 | Development on sites with less than the minimum lot size requires a use permit. | Lot Width (feet) minimum | Interior Lot | 50 | 100 | 100 | | Corner Lot | 60 | 110 | 110 | | Lot Depth (feet) minimum | 100 | 100 | 100 | | Building Height (feet) | Minimum | 30 | 30 | – | | Maximum | 70 | 200 | 140(8) | In DMX, increased height may be allowed with a use permit. | Building Height – First floor minimum (feet, floor to floor height)(2) | 15 | 15 | – | | Setbacks (feet) required minimum(3) | Front | 0 | 10 | 10 | | Interior Side | 0(7, 9) | 0 | 10 | CDC 18.150.180, Transitional requirements | Corner Side | 0(9) | 10 | 10 | | Rear | 0(7, 9) | 0 | 0 | | Front and Street Side Yard required maximum | 10 | – | – | | Open Space/Unit (square feet) minimum | 200 | 175 | – | See CDC 18.150.100, Open space and recreational facilities for residential developments (1) See Division IV (General Development Standards) and Division V (Standards for Specific Uses) of this title for additional requirements. Lot area, width, depth and setback limits listed here may not apply if a site in DP or DMX is subdivided into individual multifamily fee simple/condominium units. (2) Nonresidential building height and setbacks shall be established specified by the permit, except when permit does not regulate a standard regulated by an abutting district, or if permit is not required, the regulations of abutting district shall apply to adjacent portion of the property. (3) Measured from property line to face of building or structure. (4) Standard does not apply to small, independent parcels corresponding to individual dwellings within a larger multifamily residential, mixed-use, or townhome development. (5) Parking structures are included within the FAR calculation, unless located below grade. For structures only partially above grade, the portion above ground level will be calculated towards the floor area ratio. Refer to the parking ordinance. (6) Projects outside of minimum and maximum FAR range may be allowed subject to use permit approval. (7) For residential uses five to 10 feet, with at least 50 percent of facade at 10 feet. (8) For residential uses, minimum of 10 feet. (9) Setback area shall be paved for public use if needed for a wider public sidewalk. Two of the five feet may be landscaped. (10) Corner lots adjacent to an R or NTS district, corner side yard shall be minimum 10 feet. Where side or rear lot line abuts a lot in an R or NTS district, the minimum side or rear yard shall be the same as required in abutting R or NTS district. (11) Height shall comply with Contra Costa County airport land use plan. See Chapter 18.100 CDC, Airport Overlay District (A). [Ord. 13-5; Ord. 12-5; Ord. 12-4. DC 2012 § 122-155].
Ask a question about Concord law
Corpus searches the Concord sections it holds and shows the ones that match, with their citations. Free, no sign-in.
