15.07.090 Amendment- Chapter 44 Referenced Standards.
"Chapter 44 - Referenced Standards is adopted in its entirety with the following amendments: NFPA 13D 2025 Edition Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes is hereby amended as follows: Section 4.1.4 is hereby added to read as follows: 4.1.4 Stock of Spare Sprinklers 4.1.4.1 A supply of at least two sprinklers of each type shall be maintained on the premises so that any sprinklers that have operated or been damaged in any way can be promptly replaced. 4.1.4.2 The spare sprinklers shall be the same types and temperature ratings as installed in the dwelling. 4.1.4.3 The sprinklers shall be kept in a cabinet located where the temperature to which they are subjected will at no time exceed 100°F. 4.1.4.4 A special sprinkler wrench shall be provided and kept in the spare head cabinet to be used in the removal and installation of sprinklers. One sprinkler wrench shall be provided for each type of sprinkler installed. Section 7.3 Pressure Gauges is amended to add the following Subsection 7.3.4 to read as follows: 7.3.4 Pressure Gauges At least one water pressure gauge shall be installed on the riser assembly. Section 7.6 Alarms is hereby amended its entirety to read as follows: 7.6 Alarms. Exterior alarm indicating device shall be listed for outside service and audible from the street from which the house is addressed. Exterior audible devices shall be placed on the front or side of the structure and the location subject to approval by the fire code official. Additional interior alarm devices shall be required to provide audibility throughout the structure and shall be powered from an uninterruptible circuit serving normally operated appliances in the residence. Exception: 1. When an approved water flow monitoring system is installed, interior audible devices may be powered through the fire alarm control panel. 2. When single or multiple station smoke alarms specified in CBC 907.2.11 are used to sound an alarm upon water flow switch activation." (Ord. 3421 § 5 (part), 2025; Ord. 3357 § 5 (part), 2022; Ord. 3306 § 6 (part), 2019; Ord. 3251 § 5 (part), 2016; Ord. 3159 § 5 (part), 2013; Ord. 3059 § 5 (part), 2010.)
Ask a question about Corona law
Corpus searches the Corona sections it holds and shows the ones that match, with their citations. Free, no sign-in.