8.50.060 - New underground storage facilities.

Every underground storage tank installed after January 1, 1984, shall meet the following requirements: A. Be designed and constructed to provide primary and secondary levels of containment of the hazardous substances stored in them in accordance with the following performance standards: 1. Primary containment shall be product-tight, 2. Secondary containment shall be constructed to prevent structural weakening as a result of contact with any released hazardous substances, and also shall be capable of storing for the maximum anticipated period of time necessary for the recovery of any released hazardous substance, 3. In the case of an installation with one primary container, the secondary containment shall be large enough to contain at least one hundred percent of the volume of the primary tank, 4. In the case of multiple primary tanks, the secondary container shall be large enough to contain one hundred fifty percent of the volume of the largest primary tank placed in it, or ten percent of the aggregate internal volume of all primary tanks, whichever is greater, 5. If the facility is open to rainfall, then the secondary containment must be able to additionally accommodate the volume of a twenty-four hour rainfall as determined by a one-hundred-year storm history, 6. Single-walled containers do not fulfill the requirements of an underground storage tank providing for both a primary and a secondary containment, 7. The design and construction of underground storage tanks for motor vehicle fuels storage need not meet the requirement of subdivisions (1) through (6) of this subsection, if the primary containment construction is of glass fiber reinforced plastic, cathodically protected steel, or steel clad with glass-fiber reinforced plastic, and if any such alternative primary containment is installed in conjunction with a system that will intercept and direct a leak from any part of the tank to a monitoring well to detect any release of motor vehicle fuels stored in the tank and which is designed to provide early leak detection response, and to protect groundwater from releases, and if the monitoring is in accordance with the alternative method identified in Section 8.50.070. Pressurized piping systems connected to underground storage tanks used for the storage of motor vehicle fuels and monitored in accordance with subsection (B)(3) of Section 8.50.070 shall also be deemed to meet the requirements of this subdivision; B. Be designed and constructed with a monitoring system capable of detecting the entry of the hazardous material stored in the primary containment into the secondary containment. If water could intrude into the secondary containment, a means of monitoring for water intrusion and for safely removing the water shall also be provided; C. When required by the health officer and/or local authority, a means of overfill protection for any primary tank, including an overfill prevention device or an attention-getting higher level alarm, or both. Primary-tank filling operations of underground storage tanks containing motor vehicle fuels which are visually monitored and controlled by a facility operator satisfy the requirements of this subsection; D. Different substances that in combination may cause a fire or explosion, or the production of flammable, toxic or poisonous gas, or the deterioration of a primary or secondary container, shall be separated in both the primary and secondary containment so as to avoid potential intermixing; E. If water could enter into the secondary containment by precipitation or infiltration, the facility shall contain a means of removing the water by the owner or operator. This removal system shall also provide for a means of analyzing the removed water for hazardous substance contamination and a means of disposing of the water, if so contaminated, at an authorized disposal facility.

(Ord. 1009 § 1 (part), 1983)

Ask a question about Daly City law

Corpus searches the Daly City sections it holds and shows the ones that match, with their citations. Free, no sign-in.