For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14.10.060 — Irrigation design

Municipal Code, City of Elk Grove, California · Elk Grove Municipal Code § 14.10.060

Corpus is an independent public-information project, not the official City of Elk Grove website. Stable reference: corpuslaw.us/code/e493a5e4-fa22-473f-ad0f-d66920acc0ad

§ 14.10.060: Irrigation design.

A. Irrigation Design. Irrigation of all landscaped areas of any size shall comply with the following irrigation requirements and be conducted in a manner conforming to the rules and requirements of the State WELO and this chapter and shall be subject to penalties and incentives for water conservation and waste prevention, as determined and implemented by the City: 1. Areas less than ten (10) feet in width in any direction shall be irrigated with subsurface irrigation or other means that produces no water waste, runoff, or overspray. 2. Overhead irrigation shall not be permitted within twenty-four (24") inches of any nonpervious surface. These restrictions may be modified if: a. The landscape area is adjacent to pervious surfacing and no runoff occurs; or b. The adjacent nonpervious surfaces are designed and constructed to drain entirely to land-scaping. B. Residential Irrigation Requirements. All qualifying single-family and multifamily projects shall comply with the following irrigation requirements: 1. Sprinkler heads with a precipitation rate of eighty-five hundredths (0.85") inches per hour or less shall be used on slope exceeding fifteen (15%) percent or on slopes exceeding ten (10%) percent within ten (10' 0") feet of hardscapes to minimize runoff. 2. Valves and circuits shall be separated based on water use. 3. Drip or bubbler irrigation systems are required for trees. Bubblers shall be used that do not exceed one and one-half (1-1/2) gallons per minute per device. 4. Sprinkler heads must have matched precipitation rates within each control valve circuit. 5. Valves are required where elevation differences may cause low head drainage. 6. Head spacing shall be designed for head-to-head coverage. The system should be designed for minimum runoff and overspray onto nonirrigated areas. 7. All irrigation areas shall be equipped with a controller capable of dual or multiple programming. Controllers must have multiple cycle start capacity and a flexible calendar program. All irrigation systems shall be equipped with rain shut-off devices. 8. Dedicated water meter or submeter shall be required for landscape area greater than five thousand (5,000 ft2) square feet. 9. The following statement shall be on the plans: “I have complied with criteria of EGMC Chapter 14.10 and applied them accordingly for the efficient use of water in the irrigation design plan.” 10. The signature of a licensed landscape architect, certified irrigation designer, license land-scape contractor, or any other person authorized to design an irrigation system shall be on the plans. C. Nonresidential Irrigation Requirements. All qualifying commercial, office, and industrial development shall comply with the following irrigation requirements: 1. A low-pressure irrigation system (e.g., drip system) shall be provided for all landscape areas other than turf. 2. Automatic programmable controllers with check valves shall be installed in sloping areas with elevation differences of more than five (5') feet as defined from the toe to the top of slope. 3. Landscape materials with the same watering needs shall be grouped together and irrigated through separate control valves. 4. Irrigation systems shall be designed to avoid runoff, excessive low head drainage, overspray, or other similar conditions where water flows or drifts onto adjacent property, nonirrigated areas, walks, roadways, or structures. 5. The annual maintenance program with seasonal watering schedule shall be laminated and permanently posted in or near the control box on-site. 6. Dedicated water meter shall be required for landscape area of one thousand (1,000 ft2) square feet, but not more than five thousand (5,000 ft2) square feet. 7. The following statement shall be on the plans: “I have complied with criteria of EGMC Chapter 14.10 and applied them accordingly for the efficient use of water in the irrigation design plan.” 8. The signature of a licensed landscape architect, certified irrigation designer, license land-scape contractor, or any other person authorized to design an irrigation system shall be on the plans.

( Ord. 31-2017 § 3 (Exh. A), eff. 2-9-2018 ; Ord. 13-2025 § 3 (Exh. B), eff. 7-25-2025 )

Ask a question about Elk Grove law

Corpus searches the Elk Grove sections it holds and shows the ones that match, with their citations. Free, no sign-in.