For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 17.90.070 — Development standards

Municipal Code of the City of El Monte, California (Codified through Ordinance No. 3055, passed June 11, 2025. (Supp. No. 36, Update 1)) · El Monte Municipal Code § 17.90.070

Corpus is an independent public-information project, not the official City of El Monte website. Stable reference: corpuslaw.us/code/9964c040-85c3-4463-8bc3-ef3984c6857f

17.90.070 - Development standards.

A. Generally Applicable Development Standards. All new wireless facilities and collocations, modifications or other changes to existing wireless facilities not covered under Section 6409 must conform to the applicable development standards in this section: 1. Concealment. Wireless facilities must incorporate concealment elements, measures and techniques that blend the equipment and other improvements into the natural and/or built environment in a manner consistent and/or compatible with the uses germane to the underlying zoning district and existing in the immediate vicinity. As an illustration and not a limitation, a wireless facility designed to mimic a native tree species or a rock outcrop may be appropriate in an open space or hillside location where other natural elements exist to provide effective camouflaging and/or concealment. 2. Noise. Wireless facilities and all accessory equipment and transmission equipment must comply with all applicable noise control standards and regulations in Chapter 8.36 (Noise Control) of Title 8 (Health and Safety) of the El Monte Municipal Code (EMMC), and shall not exceed, either individually or cumulatively, the applicable ambient noise limit in the subject zoning district. The city may require the applicant to incorporate appropriate noise-baffling materials and/or strategies whenever necessary to avoid any ambient noise from equipment (such as backup power generators) reasonably likely to exceed the applicable limit. In the event a duly authorized federal, state, or local official declares an emergency within a region that includes the city in whole or in part, backup power generators may exceed the applicable noise control standards and regulations to the extent reasonably necessary to operate the facility until the declared emergency is lifted or power is restored to the affected facility. 3. Landscaping. All wireless facilities must include landscape features and a landscape plan when proposed to be placed in a landscaped area. The landscape plan must include existing vegetation, and vegetation proposed to be removed or trimmed, and the landscape plan must identify proposed landscaping by species type, size and location. Landscape maintenance must be performed in accordance with Chapter 17.72 (Landscaping Requirements) of this title. The city may require additional landscape features to screen the wireless facility from public view, avoid or mitigate potential adverse impacts on adjacent properties or otherwise enhance the concealment required under this chapter. 4. Site Security Measures. Wireless facilities may incorporate reasonable and appropriate site security measures, such as fences, walls and anti-climbing devices, to prevent unauthorized access, theft or vandalism. Site security measures must be designed to enhance concealment to the maximum extent possible, such as installing equipment within an enclosure designed to mimic a trash-can corral rather than within a chain link fence. The city may require additional concealment elements as deemed necessary to blend the security measures and other improvements into the natural and/or built environment. The use of barbed wire, razor ribbon, electrified fences or any similar security measures shall be prohibited. 5. Backup Power Sources. The city may approve permanent backup power sources and/or generators on a case-by-case basis. The city strongly disfavors backup power sources installed on the ground or mounted on poles within the public rights-of-way. In no event shall any diesel generator or other similar noise or noxious generated by used within two hundred fifty (250) feet of any residentially zoned property; provided, however, the city may approve sockets or other connections used for temporary backup generators. 6. Lighting. Wireless facilities may not include exterior lights other than: (a) as may be required under Federal Aviation Administration, FCC or other applicable governmental regulations; and (b) timed or motion-sensitive lights for security and/or worker safety. All exterior lights permitted or required to be installed must be installed in locations and within enclosures that mitigate illumination impacts on other properties to the maximum extent feasible. 7. Signage; Advertisements. All wireless facilities must include signage that accurately identifies the equipment owner/operator, the owner/operator's site name or identification number and a toll-free number to the owner/operator's network operations center. Wireless facilities may not bear any other signage or advertisements unless expressly approved by the city, required by law or recommended under FCC or other United States governmental agencies for compliance with radiofrequency (RF) emissions regulations. 8. Future Collocations and Equipment. To the maximum extent feasible and aesthetically desirable, all new wireless facilities should be designed and sited in a manner that accommodates potential future collocations and equipment installations that can be integrated into the proposed wireless facility or its associated structures with no or negligible visual changes to the outward appearance. 9. Utilities. All cables and connectors for telephone, primary electric and other similar utilities must be routed underground to the maximum extent feasible in conduits large enough to accommodate future collocated wireless facilities. Meters, panels, disconnect switches and other associated improvements must be placed in inconspicuous locations to the extent possible. The city shall not approve new overhead utility lines or service drops merely because compliance with the undergrounding requirements would increase the project cost; provided, however, that the Community Development Director or Public Works Director may waive this requirement to the extent the approval of new overhead lines or service drops would amount to a de minimis visual change. Microwave or other wireless backhaul is discouraged when it would involve a separate and unconcealed antenna (i.e. the city strong prefers the undergrounding of wirelines in lieu of wireless backhauls). 10. Parking and Access. Any equipment or improvements constructed or installed in connection with any wireless facilities must not reduce any parking spaces below the minimum requirement for the subject property. Whenever feasible, wireless facilities should use existing parking and access rather than construct new parking or access improvements. Any new parking or access improvements should be the minimum size necessary to reasonably accommodate the proposed use. 11. Compliance with Laws. All wireless facilities must be designed and sited in compliance with all applicable federal, state and local laws, regulations, rules, restrictions and conditions. This includes, without limitation, the California Building Standards Code, general plan, EMMC and any applicable specific plan and any conditions or restrictions in any permit or other governmental approval issued by any public agency with jurisdiction over the facility. B. Freestanding Wireless Facilities. In addition to the requirements in subsection A. above, all new freestanding wireless facilities and collocations, revisions or other changes to existing freestanding wireless facilities not covered under Section 6409 shall conform to the following: 1. Height. Freestanding facilities shall not exceed the applicable height limit established for the subject zoning district or overlay zone. 2. Setbacks. Wireless facilities shall not encroach into any applicable setback for structures in the subject zoning district. 3. Tower-Mounted Equipment. All tower-mounted equipment shall be mounted to the vertical support structure as close as possible to reduce its overall visual profile. Applicants must mount non-antenna, tower-mounted equipment (including, but not limited to, remote radio units/heads, surge suppressors and utility demarcation boxes) directly behind the antennas to the maximum extent feasible. All tower-mounted equipment, cables and hardware must be painted with flat colors subject to approval by the Planning Commission or Planning Division. 4. Ground-Mounted Equipment; Shelters. All ground-mounted equipment shall be concealed underground or within an existing or new structure, opaque fences or other enclosures subject to approval by the Planning Commission or Planning Division. The Planning Division may require additional concealment elements as deemed necessary to blend the ground-mounted equipment and other improvements into the natural and/or built environment. C. Building-Mounted Wireless Facilities. In addition to the requirements in subsection A above, all new building-mounted wireless facilities and collocations, modifications or other changes to existing building-mounted wireless facilities not covered under Section 6409 must conform to the following: 1. Height. Building-mounted wireless facilities shall not exceed the applicable height limit established for the subject zoning district or overlay zone, except as permitted in Section 17.60.030 (General Development Standards—Height Exceptions and Restrictions) of this title. 2. Setbacks. Wireless facilities shall not encroach into any applicable setback for structures in the subject zoning district, except as permitted in Section 17.60.130 (General Development Standards—Yard Encroachments) of this title. 3. Preferred Concealment Techniques. All applicants should, to the maximum extent feasible, propose new non-tower wireless facilities that are completely concealed and architecturally integrated into the existing façade or rooftop features with no visible impacts from any publicly accessible areas at ground level (examples include, but are not limited to, antennas behind existing parapet walls or façades replaced with RF-transparent material and finished to mimic the replaced materials). Alternatively, when integration with existing building features is not feasible, the applicant should propose completely concealed new structures or appurtenances designed to mimic the support structure's original architecture and proportions (examples include, but are not limited to, cupolas, steeples, chimneys and water tanks). Facilities must be located behind existing parapet walls or other existing screening elements to the maximum extent feasible. 4. Façade-Mounted Equipment. When wireless facilities cannot be placed behind existing parapet walls or other existing screening elements, the Planning Division may approve façade-mounted equipment in accordance with this section. All façade-mounted equipment must be concealed behind screen walls and mounted as flush to the façade as practicable. The Planning Division may not approve "pop-out" screen boxes unless the design is architecturally consistent with the original building or support structure. The Planning Division shall not approve any exposed façade-mounted antennas, including, but not limited to, exposed antennas painted to match the façade. To the maximum extent feasible, façade-mounted equipment must be installed on the façade(s) along the building frontage that is the least prominent or publicly visible. 5. Rooftop-Mounted Equipment. All rooftop-mounted equipment must be screened from public view with concealment measures that match the underlying structure in proportion, quality, architectural style and finish. The Planning Division may approve unscreened rooftop equipment only when it expressly finds that such equipment is effectively concealed due to its low height and/or setback from the roofline. 6. Ground-Mounted Equipment; Shelters. All ground-mounted equipment must be concealed underground or within an existing or new structure, opaque fences, building interior equipment room, or other enclosures subject to approval by the Planning Division. The city may require additional concealment elements as deemed necessary to blend the ground-mounted equipment and other improvements into the natural and/or built environment. D. Right-of-Way Wireless Facilities. In addition to the applicable requirements in subsection 17.90.070.A. of this chapter, all new right-of-way wireless facilities and collocations, modifications or other changes to existing right-of-way wireless facilities not covered under Section 6409 must conform to the following: 1. Concealment. All wireless facilities in the right-of-way must be concealed to the maximum extent feasible with design elements and techniques that mimic or blend with the underlying support structure, surrounding environment and adjacent uses. In addition, wireless facilities in the rights-of-way may not unreasonably subject the public use, for any purpose including expressive or aesthetic purposes, to inconvenience, discomfort, trouble, annoy, hinder, impede or obstruct. 2. Overall Height. Wireless facilities in the public rights-of-way may not exceed either of the following: a. The minimum separation from supply lines required by the California Public Utilities Corporation (CPUC) General Order 95, as may be amended or superseded, plus four (4) feet; and/or b. Four (4) feet above the height of the existing support structure. To the extent that in the Public Works Director's discretion the four-foot height allowance would cause the applicant's wireless facility to be materially incompatible with the overall height or appearance of the surrounding support structures in the public right-of-way, the Public Works Director may require the applicant to propose an alternative design (such as mounting the antenna(s) on the side of the pole) or location to the maximum extent technically feasible. 3. Existing Support Structures. All wireless facilities in the public right-of-way must be installed on existing above-ground structures (such as light standards or utility poles) whenever possible. The Public Works Director shall not approve any wireless facility proposed to be installed on a traffic control pole unless the Public Works Director finds, in his or her sole discretion, that the traffic control pole has sufficient capacity to support the wireless facility. 4. Replacement Support Structures. Existing above-ground structures may be replaced with structurally hardened, fitted or reinforced support structures so long as the replacement structure is, in the Public Works Director's discretion, substantially similar to the existing structure to be replaced. 5. New Support Structures. The Public Works Director shall not approve any new, non-replacement support structures unless: a. The applicant demonstrates that above-ground support structures within the intended service area either do not exist or are not potentially available to the applicant; or b. The Public Works Director specifically finds that a new, non-replacement support structure would be more aesthetically desirable and consistent with the objectives in this chapter than installations on existing structures near the project site. The city shall have the discretion to require that any new support structure must be a streetlight that conforms to the city's streetlight standards and specifications, which the city shall maintain for street illumination and public safety purposes. 6. Undergrounded Equipment. To conceal the equipment to the maximum degree feasible, applicants must install all equipment (other than the antenna and any electric meter) underground in any area in which the existing utilities are primarily located underground. In all other areas, applicants shall install all equipment (other than the antenna and any electric meter) underground when the Public Works Director finds that the above-ground equipment would unreasonably interfere with the public's ability to use the right-of-way for uses that include without limitation travel, social, expressive and/or aesthetic uses. When making a determination on whether to require undergrounded equipment, the Public Works Director shall take into account the presence of existing above-ground utilities. Mere additional expense to install and maintain an underground equipment enclosure does not exempt an applicant from this requirement. If an applicant proposes to install a facility in an area in which the existing utilities are primarily located underground, the Public Works Director shall have the discretion, consistent with subsections 17.90.070.D.3. through D.5. above, to require that the applicant install a new streetlight that conforms to the city's streetlight standards and specifications as the facility support structure. 7. Pole-Mounted Equipment. All pole-mounted equipment must be installed as close to the pole as technically and legally feasible to minimize the overall visual profile. All pole-mounted equipment and required or permitted signage must face toward the street or otherwise placed to minimize visibility from adjacent sidewalks and structures to the maximum extent feasible. All cables, wires and other connectors must be routed through conduits within the pole whenever possible, and all conduit attachments, cables, wires and other connectors must be concealed from public view to the maximum extent feasible. 8. Ground-Mounted Equipment. To the extent that the equipment cannot be placed underground as required, applicants may be permitted to install ground-mounted equipment in a location that does not obstruct pedestrian or vehicular traffic. All ground-mounted equipment must be placed in the least conspicuous location available within a reasonable distance from the pole. The Public Works Director may conditionally approve new or enhanced landscaping to conceal ground-mounted equipment. The city shall not approve a ground-mounted electric meter pedestal or other electric meter enclosure to the maximum extent feasible. E. Administrative Design Guidelines. The Community Development Director or Public Works Director may develop, and from time to time amend, design guidelines consistent with the generally applicable development standards and any facility-specific development standards to clarify the aesthetic goals and standards in this chapter. In the event that a conflict arises between the development standards in this section and the design guidelines, the development standards in this section shall control.

(Ord. No. 3053, § 3(Exh. A), 5-14-2025)

Ask a question about El Monte law

Corpus searches the El Monte sections it holds and shows the ones that match, with their citations. Free, no sign-in.