§ 31-203 — Implementation
Code of Ordinances, City of Escondido, California (Code 2026-09-30: eCode360 publication current through the 2026-09-30 codification (imported 2026-11-21)) · Escondido Municipal Code § 31-203
Corpus is an independent public-information project, not the official City of Escondido website. Stable reference: corpuslaw.us/code/9454b8e1-6012-4b87-bd5a-ce919137ce22
§ 31-203: Implementation.
(a) No metered water service connection to any premises shall be placed in service by the city unless the city system is protected as required by the CCCPH, city’s CCCMP and by this article. Service of water to any premises shall be immediately discontinued by the city if a backflow prevention device required by this article is not installed, tested and maintained, or if a backflow prevention device has been removed, bypassed, or if an unprotected crossconnection exists on the premises. Service will not be restored until such conditions or defects are corrected. (b) All customer systems shall be open for inspection at all reasonable times to authorized representatives of the city to enable the city to ascertain the existence of cross-connections and compliance with this article of this Code. Any violation of this article shall be grounds for the city to deny or immediately discontinue service to the premises by providing for a physical break in the service line until the customer has corrected the condition(s). (c) An approved backflow prevention device shall be installed on each metered water service connection to a customer system at or near the property line or immediately inside the building being served; but, in all cases, such device shall be installed before the first branch line leading off the service wherever the following conditions exist: (1) In the case of premises having an auxiliary water supply. (2) In the case of premises on which any industrial fluid is handled in such a fashion as to create an actual or potential hazard to the city system, including the handling of process waters and waters originating from the city system which have been subject to deterioration in quality, the city system shall be protected against backflow. (3) In the case where internal cross-connections cannot be permanently corrected or controlled. (4) In the case where there are intricate plumbing and piping arrangements. (5) Where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross-connections exist. (d) The type of protective device required by section 31-203(c) shall depend upon the degree of hazard which exists as follows: (1) In the case of any premises where there is an auxiliary water supply as stated in subsection (c)(1), and such supply is not subject to any of the following rules, the city system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device. (2) In the case of any premises where there is water or substance that would be objectionable, but not hazardous to health, if introduced into the city system, the city shall be protected by an approved reduced pressure principle backflow prevention device. (3) In the case of any premises where there is any material dangerous to health which is handled in such a fashion as to create an actual or potential hazard to the city system, the city system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device. Examples of premises where these conditions will exist include sewage treatment plants, sewage pumping stations, chemical manufacturing plants, hospitals, mortuaries and plating plants. (4) In the case of any premises where there are cross-connections, either actual or potential, the city system shall be protected by an approved air-gap water separation or an approved reduced pressure principle backflow prevention device. (5) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete a hazard assessment, the city system shall be protected against backflow on back-siphonage from the premises by the installation of a backflow prevention device. In this case, maximum protection will be required; that is, an approved air-gap separation or an approved reduced pressure principle backflow prevention device shall be installed in each metered water service connection to the premises. (6) A lead-free reduced pressure backflow preventer will be required by the City for any hazard identified on the premises as outlined in Appendix E of the CCCMP. (7) An air-gap system installed as near to the metered water service connection as possible will be required where toxic wastes injurious materials are pumped or where reclaimed water is used to supplement the city supplied water. (e) Any backflow prevention device required by this article shall be of a model and size approved by the city. The term "approved backflow prevention device" shall mean a device that has been manufactured in full conformance with the standards established by the American Water Works Association, as set forth in its publication entitled, "AWWA C511-17 Standards for Reduced-Pressure Principle Backflow Prevention Assembly" and, that has met completely the laboratory and field performance specifications of the Foundation for Cross-Connection Control and Hydraulic Research of the University of Southern California, as set forth in its publication entitled, "Specifications of Backflow Prevention Devices - 2079-84 dated March 1982" or the most recent edition. Final approval shall be evidenced by a "certificate of approval" issued by an approved testing laboratory, certifying full compliance with the standards and specifications set forth above. (f) It shall be the duty of the customer/user at any premises where backflow prevention devices are installed to have certified inspections and operational tests made at least once per year. These inspections and tests shall be at the expense of the customer/user, and shall be performed by persons who have demonstrated their competency in the testing of these devices to the city. The city shall establish deadlines as to when these tests shall be performed. The customer/user shall notify the city in advance when the tests are to be undertaken so that city personnel may witness the tests if it is so desired. These devices shall be repaired, overhauled or replaced at the expense of the customer/user whenever the devices are defective. Records of such test, repairs and overhaul shall be kept and made available to the city for at least three years.
( Ord. No. 88-27 , § 1, 5-11-88 ; Ord. No. 2025-08 , 12/17/2025 )
Ask a question about Escondido law
Corpus searches the Escondido sections it holds and shows the ones that match, with their citations. Free, no sign-in.