§ 25.23.3 — General Development Regulations
City Code, City of Fairfield, California (Fairfield City Code includes legislation through 07-21-2026 (eCode360 publication FA4438, scraped 2026-11-21)) · Fairfield City Code § 25.23.3
Corpus is an independent public-information project, not the official City of Fairfield website. Stable reference: corpuslaw.us/code/5da0c811-153e-41bb-a70d-f1776acf0965
§ 25.23.3: General Development Regulations.
All new development, subdivisions, establishment of new land uses, and alterations to existing land uses, structures and site improvements, shall be designed and constructed in compliance with the regulations in the following tables, except those activities and land uses specified in Section 25.10.6 (Exemptions from Zoning Ordinance Requirements). Additional Zoning Ordinance regulations may apply as referenced in the tables, as well as other City Code regulations City Standards, Specifications and Details, or regulations of another local agency, special district, and State or Federal agency. In addition, development in the Heart of Fairfield Plan Areas must be consistent with the vision, goals, objectives, and design concepts outlined in the Plan. The Heart of Fairfield Zoning General Development Regulations, unlike the zone-based regulations in other Sections of this Ordinance, are based on building type. Building types specifically addressed in this Ordinance include non-residential (commercial, office, and institutional buildings), multifamily (apartments and townhouses with at least three attached dwelling units), single family homes, and mixed use (commercial/institutional and residential buildings). Specific guidelines are also established for the proposed Fairfield Transportation Center parking structure on Auto Mall Parkway. Table 25-H2: Development Regulations for Commercial (Non-Residential) Buildings Regulations (all figures are minimums measured from property lines and in linear feet, unless otherwise indicated) | HD/HDC | HWT | HO | HTD | Sections and Footnotes Heart of Fairfield Land Use Designation | CD-CDC | MU-WTS | MU-O | MU-TOD Site Planning Lot Area (sq. ft. for new subdivisions only) | 6,000 | 10,000 | 6,000 | 15,000 Lot Dimensions (for new subdivisions only) Width | 60' | 80' | 60' | 100' Depth | 100' | 120' | 100' | 150' Floor Area Ratio | 3.0 | 2.0 | 2.0 | 3.0 | Note 1 Commercial Buildings-Where Permitted | No restrictions | Commercial buildings permitted only on parcels with West Texas Street and Beck Avenue access | No restrictions | No restrictions Parking | | | | | Note 2, Note 3 See Section 25.28.3 Number of spaces required | 1 space per 1,000 square feet | See Section 25.34 | See Section 25.28.3 and 25.34 | See Section 25.34 Private surface lot location and access | Rear or side only. No access from Texas Street. | Rear or side only | Rear or side only | Rear or side only Landscaping Depth @ street frontage | 4' | 10' | 8' | 5' | Note 5, Note 6 Depth @ interior property line | 0' | 5'; 0' if side building setback is 0' | 5' | 5' Depth adjacent to residential zone or use | 0' | 5' | 5' | 5' | Note 5 Street tree spacing (one tree for each ...) | 30' | 30' | 30' | 30' Outdoor Seating or Merchandise Display | See Section 25.32.9 Activity Zone | 4' along Texas Street; 0' elsewhere | 0' | 0' | 4' | Note 7 Buildings Building Height Limit | 50' | 50' | 45' | 65' | Note 1 Number of Habitable Floors | 2 minimum | 2 minimum | No requirement | Exactly 2 floors facing Webster Street; 3 floors facing other streets Building-Streetscape Interface Ground floor ceiling heights | 14' | Note 4, Note 9 Ground floor transparency | 75% on Texas Street; 50% on other streets | 50% | 50% | 50% | Note 4, Note 9 Upper floor transparency | 30% | 30% | 30% | 30% | Note 4, Note 9 Front pedestrian entrance from street | Required; may provide private entrances off a courtyard with a shared entrance off street | Note 4 Setbacks Front and street side minimum (maximum setbacks) | 0'; (5') | 11' (16') | 12' measured from back of curb (15' measured from curb) | 13' measured from back of curb (15' measured from curb) | Note 10 Interior side ... minimum | 0' on Texas Street; 10' on other streets | 0' where permitted | 10' | 10' ... abutting residential zone or use | 0' on Texas Street; 10' on other streets | 0' where permitted | 10' | 10' Rear ... minimum | 10'; 0' facing alley | 15' | 10' | 10' | Note 8 ... abutting residential zone or use | 10' | 15' | 10' | 10' Upper floor (fourth floor and higher) additional setbacks | 0' in HDC and in HD for buildings fronting on Texas Street; 10' setback from edges of building façade on other streets. | 10' additional setbacks from edge of building façade | 15' additional setbacks from edge of building façade | 10' additional setbacks from edge of building façade Notes: (1) | An increase in the Floor Area Ratio or Building Height is allowed with approval of a Conditional Use Permit (see Section 25.40.6). (2) | Refer to P-1 Overlay District to understand when parking required. (3) | Fifty percent of any required parking may be provided through on-street parking located within 300 feet of the parcel line and the remaining 50% may be provided on any private parcel or public parking facility within 750 feet of the parcel line. Proof of authorization is required to use any private parcel or public parking facility for parking. (4) | In the HWT Zone, this applies only to properties with access from West Texas Street. (5) | Landscaping depth includes required “Amenity Zone” improvements in the public right-of-way described in Table 4.1 in the Heart of Fairfield Plan (and defined in Section 25.50.2.A). In areas where the Amenity Zone contains street tree grates, the area between the gates may be comprised of sidewalk and other Amenity Zone improvements authorized by the Plan or consistent with the Downtown Streetscape Project. (6) | Landscaping depth may include “Activity Zone” improvements described in Table 4.1 of the Heart of Fairfield Plan (and defined in Section 25.50.2.A). (7) | See Heart of Fairfield Plan for description of the Activity Zone. (8) | In the HWT Zone, an additional 1' of setback shall be provided for each 1' of building height over 20', up to 40' maximum setback. (9) | Transparency is defined as vertical surfaces constructed with transparent materials (e.g., glass windows or storefronts). (10) | In the HWT Zone, for properties located in the “bookends” defined in the Heart of Fairfield Plan, an additional 4' front setback applies. Table 25-H3: Development Regulations for Multifamily Buildings Regulations (all figures are minimums measured from property lines and in linear feet, unless otherwise indicated)Heart of Fairfield Land Use Designation | HD/HDCCD-CDC | HWTMU-WTS | HOMU-O | HTDMU-TOD | HRRM-D | Sections and Footnotes Site Planning Density (dwelling units per acre) | 15-48 | 15-48 | 8-35 | 20-80 | 8-35 | Note 1 Lot Area (sq.ft., for new subdivisions only) | 7,500 | 7,500 | 7,500 | 7,500 | 7,500 Lot Dimensions (for new subdivisions only) Width | 50' | 50' | 50' | 50' | 50' Depth | 150' | 150' | 150' | 150' | 150' Lot Coverage (%) | 100% | 60% | 60% | 60% | 60% | Note 1 Multifamily Building-Where Permitted | Not permitted to face onto Texas Street | No restrictions | No restrictions | No restrictions | No restrictions Parking Number of spaces required | 1 space per unit | 1 1/3 spaces per unit | 1 1/3 spaces per unit | 1 1/3 spaces per unit | 1 1/3 spaces per unit | Note 2 Private surface lot location and access | Rear or side only; no access from Texas Street | Rear or side only | Rear or side only | Rear or side only | Rear or side only; rear alley access only Open Space and Recreational Amenities Common open space (as percentage of net parcel area) | 0% | 25% | 25% | 0% | 25% | Includes shared courtyards and useable yards. 50% of common open space must be “usable” as defined in Section 25.20.4.8 A. Note 9, Note 10 Private open space (ground floor/upper floor in square feet) | 48 | Buildings fronting West Texas Street: 48 sf; other streets: 80/48 | 80/48 | 48 | 80/48 | Includes balconies, rooftop open spaces, courtyards, yards. For buildings facing West Texas, solid portions of fence enclosing open spaces cannot exceed 42" in height Recreational amenities | Required | Required | See Section 25.20.4.8 B. Note 10 Landscaping Depth @ street frontage | 4' | 10' | 8' | 5' | 8' | Note 3, Note 4, Note 10 Depth @ interior property line | 0' | 5'; 0' if side building setback is 0' | 5' | 5' | 5' Depth adjacent to residential zone or land use | 0' | 5' | 5' | 5' | 5' Street tree spacing (one tree for each ...) | 30' | 30' | 30' | 30' | 30' Laundry Facilities | Required Storage Space (private square footage per unit) | 100 cubic feet per unit Trash Enclosures (including recyclables) | Required | Section 25.30.7 Buildings Building Height Limits | 60' | 50' | 45' | 65' | 35'; except 40' on Broadway or Pennsylvania | Note 1 Number of Habitable Floors | 2 minimum | 2 minimum | No Minimum | Exactly 2 floors facing Webster Street; 3 floors facing other streets | 2 floors required on Broadway and Pennsylvania Building-Streetscape Interface Garage location and entrance | Garages may not face public street(s) unless located on back half of lot Ground floor transparency | 50% | 50% | 30% | 30% | 30% | Note 6 Upper floor transparency | 30% | 30% | 30% | 30% | 30% | Note 6 Front pedestrian entrance from street | Required; may provide private entrances off a courtyard with a shared entrance off street Setbacks Front and street side minimum (maximum setbacks) | 0' where permitted (5') | 11' (18') | 12' measured from back of curb (15' measured from property line) | 13' measured from back of curb (15' measured from property line) | 10' (20') | Note 8 Interior side minimum | 5' where permitted | 10' | 10' | 10' | 5' minimum, 15' total Rear | 10' where permitted | 10.0 | 10 | 10.0 | 15' to habitable building; 0' to alley Accessory structures: | 5' | 5' | 5' | 5' | 5' Upper floor (fourth floor and higher) additional setbacks | 10' setback from edges of building façade | 10' setback from edges of building façade | 15' setback from edges of building façade | 10' setback from edges of building façade | 15' setback from edges of building façade Between any two buildings: front to front | 15' minimum, 30' average | 15' minimum, 30' average | 15' minimum, 30' average | 15' minimum, 30' average | 15' minimum, 30' average | Note 7 Between any two buildings: front to rear | Not permitted | Not permitted | Not permitted | Not permitted | Not permitted Between any two buildings: rear to rear | 26' | 26' | 26' | 26' | 26' | Note 7 Between any two buildings: side to side | 10'; or exactly 0' | 10'; or exactly 0' | 10' | 10'; or exactly 0' | 10' Upper Floor Encroachments | 3' projection of architectural features into setbacks | 5' projection of architectural features into front setbacks, 0' into rear | 5' projection of architectural features into front setbacks, 0' into rear | 5' projection of architectural features into front setbacks, 0' into rear | 5' projection of architectural features into front setbacks, 0' into rear Notes: (1) | An increase in the Floor Area Ratio or Building Height is allowed with approval of a Conditional Use Permit (see Section 25.40.6). (2) | Fifty percent of any required parking may be provided through on-street parking located within 300 feet of the parcel line and the remaining 50% may be provided on any private parcel or public parking facility within 750 feet of the parcel line. Proof of authorization is required to use any private parcel or public parking facility for parking. (3) | Landscaping depth includes required “Amenity Zone" improvements in the public right-of-way described in Table 4.1 in the Heart of Fairfield Plan (and defined in Section 25.50.2.A). In areas where the Amenity Zone contains street tree grates, the area between the gates may be comprised of sidewalk and other Amenity Zone improvements authorized by the Plan or consistent with the Downtown Streetscape Project. (4) | Landscaping depth may include “Activity Zone" improvements described in Table 4.1 of the Heart of Fairfield Plan (and defined in Section 25.50.2.A). (5) | Restrictions not applied to garages facing an alley or located on the rear half of lot. (6) | Transparency is defined as vertical surfaces constructed with transparent materials (e.g., glass windows or storefronts). (7) | Where public utilities are located between buildings, separation shall be minimum 30'. (8) | In the HWT Zone, for properties located in the “bookends” defined in the Heart of Fairfield Plan, an additional 4' front setback applies. (9) | For projects within 1/2 mile of a public park or other offsite open space or amenity, common open space may be reduced to that necessary to meet landscaping and setback requirements. (10) | Landscape and hardscape improvements within the current public right of way that provide recreational or open space amenities as envisioned in the Heart of Fairfield Plan may be counted towards the common open space, landscaping, and recreational amenity requirements. Table 25-H4: Development Regulations for Mixed Use (Properties with a Mixture of Residential and Commercial Development) (all figures are minimums measured from property lines and in linear feet, unless otherwise indicated)Heart of Fairfield Land Use Designation | HD/HDCCD-CDC | HWTMU-WTS | HOMU-O | HTDMU-TOD | Sections and Footnotes Site Planning Density (dwelling units per acre) | 15-48 | 15-48 | 8-35 | 20-80 | Note 1 Lot Area (sq. ft., for new subdivisions only) | No Minimum | 7,500 | 7,500 | 7,500 Lot Dimensions (for new subdivisions only) Width | N/A | 50' | 50' | 50' Depth | N/A | 150' | 150' | 150' Floor Area Ratio | 3.0 | 2.0 | 0.6 | 3.0 | Note 1 Multifamily Housing-Where Permitted | Not permitted on first floor of Texas Street | No restrictions | No restrictions | No restrictions Commercial Buildings-Where Permitted | No restrictions | Commercial buildings permitted only on parcels with West Texas Street and Beck Avenue access | No restrictions | No restrictions Parking | | | | | Note 4See Section 25.28.3 Number of spaces required-residential | 1 space per unit | 1 space per unit | 1 space per unit | 1 space per unit Number of spaces required-commercial | 1 space per 1,000 square feet | Section 25.34 | See Section 25.28.3, Section 25.34 | Section 25.34 Private surface lot location and access | Rear or side only; no access from Texas Street | Rear or side only Open Space and Recreational Amenities Common open space (as percentage of net parcel area) | 0% | 25% | 25% | 0% | Note 9, Note 10 Private open space (ground floor/upper floor in square feet) | 48 | Buildings fronting West Texas Street: 48; other streets: 80/48 | 80/48 | 48 Recreational amenities | Required | See Section 25.20.4.8(B) Landscaping | | | | | Note 2, Note 3, Note 9 Depth @ street frontage | 4' | 10' | 8' | 5' | Note 9 Depth @ interior property line | 0' | 5'; 0' if side building setback is 0' | 5' | 5' Depth adjacent to residential zone or land use | 0' | 5' | 5' | 5' Street tree spacing (one tree for each ...) | 30' | 30' | 30' | 30' Laundry Facilities | Required Storage Space (private area per unit) | 100 cubic feet per unit Trash Enclosures (including recyclables) | Required | Section 25.30.7 Buildings Building Height Limit | 60' | 50' | 45' | 65' | Note 1 Number of Habitable Floors | 2 minimum | 2 minimum | No minimum | Exactly 2 floors facing Webster Street; 3 floors facing other streets Building-Streetscape Interface Garage location and entrance | Garages may not face public streets unless located on back half of lot Ground floor ceiling heights | 14' | 14' | No Requirement | 14' | Note 7 Ground floor transparency | 50% | 50% | 30% | 30% | Note 6 Upper floor transparency | 30% | 30% | 30% | 30% | Note 6 Front pedestrian entrance from street | Required; may provide private entrances off a courtyard with a shared entrance off street Setbacks | | | | | Note 2 Front and street side minimum setbacks (maximum setbacks) | 0' minimum, (5' maximum) | 11' (16' maximum) | 12' measured from back of curb (15' measured from property line) | 13' measured from back of curb (15' measured from property line) | Note 8 Interior side: ... minimum | 0' on Texas Street, 10' on other streets | 0' On West Texas Street; 10' in other locations | 10' | 10' Rear ... minimum | 10'; 0' facing alley | 15' | 10' | 10' Accessory structures: | 5' | 5' | 5' | 5' Between any two buildings: front to front | 15' minimum, 30' average Between any two buildings: front to rear | Not permitted Between any two buildings: rear to rear | 26' Between any two buildings: side to side | Exactly 0' or 10' | Exactly 0' or 10' | 10' | Exactly 0' or 10' Upper Floor Encroachments | 3' projection of architectural features into setbacks | 5' projection of architectural features into front setbacks, 0' into rear | 5' projection of architectural features into front setbacks, 0' into rear | 5' projection of architectural features into front setbacks, 0' into rear Notes: (1) | An increase in the Floor Area Ratio or Building Height is allowed with approval of a Conditional Use Permit (see Section 25.40.6). (2) | Landscaping depth includes required “Amenity Zone” improvements in the public right-of-way described in Table 4.1 in the Heart of Fairfield Plan (and defined in Section 25.50.2.A). In areas where the Amenity Zone contains street tree grates, the area between the gates may be comprised of sidewalk and other Amenity Zone improvements authorized by the Plan or consistent with the Downtown Streetscape Project. (3) | Landscaping depth may include “Activity Zone” improvements described in Table 4.1 of the Heart of Fairfield Plan (and defined in Section 25.50.2.A). (4) | Fifty percent of any required parking may be provided through on-street parking located within 300 feet of the parcel line and the remaining 50% may be provided on any private parcel or public parking facility within 750 feet of the parcel line. Proof of authorization is required to use any private parcel or public parking facility for parking. (5) | Restrictions not applied to garages facing an alley or located on the rear half of lot. (6) | Transparency is defined as vertical surfaces constructed with transparent materials (e.g., glass windows or storefronts). (7) | Ground floor ceiling height may be reduced for first floor residential development. (8) | In the HWT Zone, for properties located in the “bookends” defined in the Heart of Fairfield Plan, an additional 4' front setback applies. (9) | Landscape and hardscape improvements within the current public right of way that provide recreational or open space amenities as envisions in the Heart of Fairfield Plan may be counted towards the common open space, landscaping, and recreational amenity requirements. (10) | For projects within 1/2 mile of a public park or other offsite open space or amenity, common open space may be reduced to that necessary to meet landscaping and setback requirements. Table 25-H5: Development Regulations for Single Family Homes (all figures are minimums measured from property lines and in linear feet unless otherwise indicated)Heart of Fairfield Land Use Designation | HWTMU-WTS | HOMU-OCD | HRRM-D | Sections and Footnotes Site Planning Lot Area | No Minimum | No Minimum | No Minimum Lot Dimensions Width | 25' interior, 35' corner | 25' interior, 35' corner | 25' interior, 35' corner | Note 6 Depth | As required to provide private open space | As required to provide private open space | As required to provide private open space Location of Home (Street Frontage) | Any location except fronting on West Texas Street | Any location | Any location Density | 8 - 48 | 8 - 35 | 8 - 35 Parking On Site Space per Dwelling | For units larger than 960 square feet: 1 covered, 1 uncovered parking space. For units smaller than 960 square feet: 1 uncovered space Off-Site Space per Dwelling (Includes on-street parking) | 1 uncovered. Second uncovered off-site space may replace on-site space | 1 uncovered. Second uncovered off-site space may replace on-site space | 1 uncovered. Second uncovered off-site space may replace on-site space | Note 1 Driveway Widths-Maximum Percentage | 50% | 50% | 50% Open Space and Recreational Amenities Private Open Space | 280 square feet | 280 square feet | 280 square feet | Notes 2, 5 Common Open Space (Subdivisions with 20 or more units) | 5% of net subdivision area | 5% of net subdivision area | 5% of net subdivision area Landscaping | | | | Note 3 Depth @ street frontage | 10' | 8' | 8' Depth @ interior property line | 5'; 0' if side building setback is 0' | 5' | 5' Depth adjacent to residential zone or land use | 5' | 5' | 5' Street tree spacing (one tree for each ...) | 30' | 30' | 30' Residential Waste Collection and Storage | For new subdivisons with street frontage, project shall provide 12 linear feet per unit on street for toter placement.Alternatively, residential waste can be disposed of in a shared receptacle (dumpster or bin) contained within an approved trash enclosure that meets City of Fairfield standards | Note 7 Alley Development Single Family Dwellings Fronting on Alley Permitted? | With a Conditional Use Permit | Note 3 Buildings Dwelling unit size (minimum) | 200 square feet Lot Coverage Maximum | 60% | Accessory structure lot coverage regulated by Section 25.20.4.1 Building Height Limit | 35 | Note 4 Garage Width-Maximum Percentage of Façade Width (front or street side elevation) | 60% | Not applied when garages face an alley or located on the rear half Setbacks to garages if garage faces any street | 18' if garage faces interior side yard | 15' if garage faces alley or courtyard | 5' exactly or 18' Accessory Structures | Accessory structure setbacks regulated by Section 25.20.4.1 Setbacks to Habitable Structures Front or street side minimum (maximum) | 11' (16') where permitted | 12' measured from back of curb (15' measured from property line) | 10' (20') Front faces private courtyard | 5' Interior side | Either 0', 4', or as necessary to provide private open space | Note 8 Rear | 10' Upper Floor Encroachments | 5' projection of architectural features into front setbacks, 0' into rear | 5' projection of architectural features into front setbacks, 0' into rear | None Specified Notes: (1) | Parking may also be provided off-site within 750 feet of the residential parcel lines. (2) | Required private open space shall not be located in the required front yard setback, and shall have a minimum uncovered dimension of 8 feet. Partially covered or enclosed rear yard areas shall be allowed to be counted towards 50% of the required open space as long as they are completely open to the rear yard on a minimum of two sides. (3) | Housing fronting on an alley is permitted only when the alley development represents at least 1/2 block face and provides a fully improved residential environment along the alley with landscaping and street trees. (4) | An increase in Building Height is allowed with approval of a Conditional Use Permit (see Section 25.40.6). (5) | Private open space may be reduced to 80 square feet with a minimum dimension of 5 feet when the project provides at least 200 square feet per dwelling unit of common open space developed for multiple active uses, such as playgrounds, play courts, barbecue areas, pool, etc. (6) | Houses may be developed on a single parcel where common land ownership is 1) held by a homeowners association or a landlord and 2) when the approved development plan identifies private use areas for each unit that are the equivalent of property lines for site planning and setback purposes. (7) | If individual toters for each unit are used, an enclosure screened from view shall be provided. (8) | Interior side-yard setback may be reduced to three feet for structures complying with all applicable Uniform Building Code regulations. Table 25-H6: Development Regulations for HPF Zoning District (all figures are minimums measured from property lines and in linear feet, unless otherwise indicated) | Sections and Footnotes Site Planning Floor Area Ratio (max. % of net lot area) | 5.0 Lot Area (in sq. ft., for new subdivisions only) | None Lot Dimensions (for new subdivisions only) Width | None Depth | None Landscaping Depth @ street frontage (incl. hwy or fwy) | 0 Depth @ interior property lines: | 0 Minimum | 0 Street tree spacing (one tree for each ...) | 30 feet of street frontage Buildings Setbacks Front: | 0 Street side yard (min. abutting arterial) | 0 Side yard | 0 Rear yard | 0 Building Height Limit | 75
( Ord. No. 2017-14 , §§ 15, 17 ; Ord. No. 2018-03 , § 5 ; Ord. No. 2018-06 , §§ 3, 16 – 21 ; Ord. No. 2021-14 , §§ 3 (Exh. B), 7 ; Ord. No. 2023-03 , §§ 5 – 8 ; Ord. No. 2025-01 , §§ 5 – 9. )
Ask a question about Fairfield law
Corpus searches the Fairfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
