§ 25.30.7 — Trash and Recyclables Enclosures
City Code, City of Fairfield, California (Fairfield City Code includes legislation through 07-21-2026 (eCode360 publication FA4438, scraped 2026-11-21)) · Fairfield City Code § 25.30.7
Corpus is an independent public-information project, not the official City of Fairfield website. Stable reference: corpuslaw.us/code/4233bf53-acb9-4480-8ec8-f83b26f996cf
§ 25.30.7: Trash and Recyclables Enclosures.
This Section is intended to provide regulations consistent with the California Solid Waste Reuse and Recycling Access Act (Public Resources Code Sections 42900 through 42911) and the City’s adopted Source Reduction and Recycling Element. All development, except single-family attached and detached dwellings, shall provide trash and recyclable enclosures that comply with the requirements of this Section. A. Regulations by land use. New multifamily and non-residential development shall incorporate enclosures for refuse and recycling materials collection as follows: 1. Multifamily. The enclosure shall be large enough to accommodate bins holding 30 gallons of trash per household and 30 gallons of recyclables per household. 2. Non-residential. The applicant shall consult the service provider as to the size and location of any enclosure. The location shall be shown in any plans submitted to the City for approval. 3. Mixed Used Development. Mixed-use development projects, as defined in Section 25.22.4.3 (Mixed Use Residential Development Regulations), shall provide trash and recycling receptacles in aggregate of the amounts identified by this section and/or as required by the service provider. B. Location requirements. Exterior refuse enclosure shall not be located in any required front yard, street side yard, landscaped, or open space areas or any area required by the City Code to be maintained as unencumbered (e.g., required parking areas, utility rights-of-way, or easements). In addition, the enclosure(s) shall be conveniently accessible to residents and/or employees. C. Design and construction. The design and construction of the storage area shall be compatible with the surrounding structures and land uses; employ a style, materials, and colors to be consistent with any buildings on the property; and designed in compliance with the Trash Enclosure Standard Detail provided by the Director. Trash receptacle(s) shall be enclosed by a six (6) foot high masonry wall with metal, solid view obstructing gates pursuant to City standards. Within multi-family residential projects, all trash enclosures shall be provided with a shade structure. The enclosure shall include a reinforced concrete apron as approved by the Department of Public Works. Trash enclosures shall also comply with all requirements of the Fairfield-Suisun Sewer District and Solano County Environmental Health.
( Ord. No. 2011-03 , § 2 )
Ask a question about Fairfield law
Corpus searches the Fairfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.
