§ 8A.5.1.3 — Elevation and floodproofing

City Code, City of Fairfield, California (Fairfield City Code includes legislation through 07-21-2026 (eCode360 publication FA4438, scraped 2026-11-21)) · Fairfield City Code § 8A.5.1.3

Corpus is an independent public-information project, not the official City of Fairfield website. Stable reference: corpuslaw.us/code/6330461f-01ee-4a65-91ad-68ebef524b0d

§ 8A.5.1.3: Elevation and floodproofing.

(a) New construction and substantial improvement of any structure shall have the lowest floor, including basement, elevated to at least one (1) foot above the base flood elevation. Nonresidential structures may meet the standards in section 8A.5.1.3(c). Upon completion of the structure the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor and verified by the building inspector that elevation requirements have been met. Notification of compliance shall be recorded as set forth in section 8A.4.2.3(a). (b) New construction and substantial improvement of any structure in Zone AO shall have the lowest floor, including basement, elevated above the highest adjacent grade to at least one (1) foot above the depth number specified on the FIRM. If there is no depth number on the FIRM, the lowest floor, including basement, shall be elevated to at least three (3) feet above the highest adjacent grade. Nonresidential structures may meet standards in section 8A.5.1.3(c). Upon completion of the structure compliance to the elevation requirement shall be certified by a registered professional engineer or surveyor and verified by the building inspector. Notification of compliance shall be recorded as set forth in section 8A.4.2.3(b). (c) Nonresidential construction shall either be elevated in conformance with section 8A.5.1.3(a) or (b), or together with attendant utility and sanitary facilities: (1) Be floodproofed below the elevation recommended in section 8A.5.1.3 so that below the level of one (1) foot above the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water; (2) Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and, (3) Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certification shall be provided to the director of public works as set forth in section 8A.4.2.3(c). (d) Manufactured homes shall meet the above standards and also the standards in section 8A.5.5. (e) For all new construction and substantial improvements, fully enclosed areas below the lowest floor (excluding basements) that are useable solely for parking of vehicles, building access or storage, and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: A minimum of two openings located on different sides of the building having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottom of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.

( Ord. 2002-17 , § 7 ; Ord. 98-28 , § 4 ; Ord. No. 2012-14 , § 4 )

Ask a question about Fairfield law

Corpus searches the Fairfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.