§ 12-39 — Standards of construction
Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana City Code § 12-39
Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/655ed207-ab16-4e15-8429-ebfeafc89122
Sec. 12-39. - Standards of construction.
In all areas of special flood hazards, the following standards are required: (1) Anchoring. a. All new construction and substantial improvements shall be adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy. b. All manufactured homes shall meet the anchoring standards of section 12-42. (2) Construction materials and methods. a. All new construction and substantial improvement shall be constructed with materials and utility equipment resistant to flood damage. b. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. c. All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. d. Within zones AH or AO, adequate drainage paths are required around structures on slopes to guide floodwaters around and away from proposed structures. (3) Elevation and floodproofing. The federal insurance administrator will provide the data upon which floodplain management regulations shall be based. If the federal insurance administrator has not provided sufficient data to furnish a basis for these regulations in the community, the community shall obtain, review and reasonably utilize data available from other federal, state or other sources as provided by the property owner, owner's representative or applicant, pending receipt of data from the federal insurance administrator. However, when special flood hazard area designations and water surface elevations have been furnished by the federal insurance administrator, they shall apply. The symbols defining such special flood hazard designations are set forth in section 12-40. In all cases the minimum requirements governing the adequacy of the floodplain management regulations for floodprone areas adopted by the community depend on the amount of technical data formally provided to the community by the federal insurance administrator. Minimum standards for the city are as follows: a. When the federal insurance administrator has not defined the special flood hazard areas within the community, has not provided water surface elevation data, and has not provided sufficient data to identify the floodway, but the community has indicated the presence of such hazards by submitting an application to participate in the program, the community shall: 1. Require permits for all proposed construction or other development in the community, including the placement of manufactured homes, so that it may determine whether such construction or other development is proposed within floodprone areas. 2. Review proposed development to ensure that all necessary permits have been received from those governmental agencies from which approval is required by federal or state law, including section 404 of the Federal Water Pollution Control Act Amendments of 1972, 33 USC 1334. 3. Review all permit applications to determine whether proposed building sites will be reasonably safe from flooding. If a proposed building site is in a floodprone area, all new construction and substantial improvements shall be designed or modified and adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; be constructed with materials resistant to flood damage; be constructed by methods and practices that minimize flood damages; and be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. 4. Review subdivision proposals and other proposed new development, including manufactured home parks or subdivisions, to determine whether such proposals will be reasonably safe from flooding. If a subdivision proposal or other proposed new development is in a floodprone area, any such proposals shall be reviewed to ensure that all such proposals are consistent with the need to minimize flood damage within the floodprone area; all public utilities and facilities, such as sewer, gas, electrical, and water systems are located and constructed to minimize or eliminate flood damage; and adequate drainage is provided to reduce exposure to flood hazards. 5. Require within floodprone areas new and replacement water supply systems to be designed to minimize or eliminate infiltration of floodwaters into the systems. 6. Require within floodprone areas new and replacement sanitary sewage systems to be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems to be located to avoid impairment to them or contamination from them during flooding. b. When the federal insurance administrator has designated areas of special flood hazards (A zones) by the publication of the community's FIRM, but has not produced water surface elevation data or identified a floodway, the community shall: 1. Require permits for all proposed construction and other developments, including the placement of manufactured homes, within zone A on the community's FIRM. 2. Require the application of the standards in subsections (3)a.2, (3)a.3, (3)a.4, (3)a.5, and (3)a.6 of this section to development within zone A on the community's FIRM. 3. Require that all new subdivision proposals and other proposed developments, including proposals for manufactured home parks and subdivisions, greater than 50 lots or five acres, whichever is the lesser, include within such proposals base flood elevation data. 4. Obtain, review and reasonably utilize any base flood elevation and floodway data available from a federal, state, or other source, including data developed pursuant to subsection (3)b.3 of this section, as criteria for requiring that new construction, substantial improvements, or other development in zone A on the community's FIRM meet the standards in subsections (3)c.2, (3)c.3, (3)c.5, (3)c.6, (3)c.12, (3)c.14, (3)d.2 and (3)d.3 of this section. 5. Where base flood elevation data are utilized within zone A on the community's FIRM: i. Obtain the elevation, in relation to mean sea level, of the lowest floor, including basement, of all new and substantially improved structures; ii. Obtain, if the structure has been floodproofed in accordance with subsection (3)c.3.ii of this section, the elevation, in relation to mean sea level, to which the structure was floodproofed; and iii. Maintain a record of all such information with the official designated by the community under section 12-41. 6. Notify, in riverine situations, adjacent communities and the state coordinating office prior to any alteration or relocation of a watercourse, and submit copies of such notifications to the federal insurance administrator. 7. Ensure that the flood-carrying capacity within the altered or relocated portion of any watercourse is maintained. 8. Require that all manufactured homes to be placed within zone A on the community's FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not to be limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. c. When the federal insurance administrator has provided a notice of final flood elevations for one or more special flood hazard areas on the community's FIRM and, if appropriate, has designated other special flood hazard areas without base flood elevations on the community's FIRM, but has not identified a regulatory floodway, the community shall: 1. Require the standards of subsection (3)b of this section within all A1—30 zones, AE zones, A zones, AH zones, and AO zones, on the community's FIRM. 2. Require that all new construction and substantial improvements of residential structures within zones A1-30, AE and AH zones on the community's FIRM have the lowest floor, including basement, elevated to or above the base flood level. 3. Require that all new construction and substantial improvements of nonresidential structures within zones A1—30, AE and AH zones on the community's FIRM: i. Have the lowest floor, including basement, elevated to or above the base flood level; or ii. Together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. 4. Provide that where a nonresidential structure is intended to be made watertight below the base flood level: i. A registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of subsection (3)c.3.ii or (3)c.8.ii of this section; and ii. A record of such certificates which includes the specific elevation, in relation to mean sea level, to which such structures are floodproofed, shall be maintained with the official designated by the community under section 12-41. 5. Require, for all new construction and substantial improvements, that fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottoms of all openings shall be no higher than one foot above grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. 6. Require that manufactured homes that are placed or substantially improved within zones A1—30, AH, and AE on the community's FIRM on sites: i. Outside of a manufactured home park or subdivision; ii. In a new manufactured home park or subdivision; iii. In an expansion to an existing manufactured home park or subdivision; or iv. In an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as the result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to or above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation collapse and lateral movement. 7. Require that within an AO zone on the community's FIRM that all new construction and substantial improvements of residential structures have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM, at least two feet if no depth number is specified. 8. Require that within any AO zone on the community's FIRM that all new construction and substantial improvements of nonresidential structures: i. Have the lowest floor, including basement, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM, at least two feet if no depth number is specified; or ii. Together with attendant utility and sanitary facilities be completely floodproofed to that level to meet the floodproofing standard specified in subsection (3)c.ii of this section. 9. Require that within any A99 zones on the community's FIRM the standards of subsections (3)a.1 through (3)a.4.i and (3)b.5 through (3)b.8. 10. Require, until a regulatory floodway is designated, that no new construction, substantial improvements, or other development, including fill, shall be permitted within zones A1—30 and AE on the community's FIRM, unless it is demonstrated that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water more than one foot at any point within the community. 11. Require within zones AH and AO adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures. 12. Require manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within zones A1-30, AH, and AE on the community's FIRM that are not subject to the provisions of subsection (3)c.6 of this section be elevated so that either: i. The lowest floor of the manufactured home is at or above the base flood elevation; or ii. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and are securely anchored to an adequately anchored foundation system to resist floatation, collapse, and lateral movement. 13. Notwithstanding any other provisions of subsection (3) of this section, a community may approve certain development in zones A1—30, AE, and AH, on the community's FIRM which increases the water surface elevation of the base flood by more than one foot, provided that the community first applies for a conditional FIRM revision, fulfills the requirements for such a revision, as established under the provisions of section 12-42, and receives the approval of the federal insurance administrator. 14. Require that recreational vehicles placed on sites within zones A1-30, AH, and AE on the community's FIRM either: i. Be on the site for fewer than 180 consecutive days; ii. Be fully licensed and ready for highway use; or iii. Meet the permit requirements of subsection (3)b.1 and elevation and anchoring requirements for manufactured homes in subsection (3)c.6 of this section. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. (4) When the federal insurance administrator has provided a notice of final base flood elevations within zones A1—30 and/or AE on the community's FIRM and, if appropriate, has designated AO zones, AH zones, A99 zones, and A zones on the community's FIRM, and has provided data from which the community shall designate its regulatory floodway, the community shall: a. Meet the requirements of subsection (3)a through (3)n of this section. b. Select and adopt a regulatory floodway based on the principle that the area chosen for the regulatory floodway must be designed to carry the waters of the base flood, without increasing the water surface elevation of that flood more than one foot at any point. c. Prohibit encroachments, including fill, new construction, substantial improvements, and other development within the adopted regulatory floodway unless it has been demonstrated through hydrologic and hydraulic analyses performed in accordance with standard engineering practice that the proposed encroachment would not result in any increase in flood levels within the community during the occurrence of the base flood discharge. d. Notwithstanding any other provisions of subsection (3) of this section, the community may permit encroachments within the adopted regulatory floodway that would result in an increase in base flood elevations, provided that the community first applies for a conditional FIRM and floodway revision, fulfills the requirements for such revisions as established under the provisions of section 12-42, and receives the approval of the federal insurance administrator.
(Code 1968, § 8-65; Ord. No. 1078, § 2(8-60), 5-25-93)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.
