Sec. 23-163. - Food processing facilities—Permit, interceptor requirement.
(a) Food processing facilities must submit a wastewater discharge permit application to the public works director prior to certificate of occupancy approval. (b) All food processing facilities shall install a gravity separation interceptor that meets the following requirements: (1) Except as approved by the public works director and building official consistent with the California Plumbing Code, all sinks, drains, and other fixtures or equipment in a food processing facility that may discharge fats, oils, or grease in amounts that could cause a blockage or interfere with the sewer system shall discharge through the grease interceptor, including pot sinks; wash sinks; sinks used for food preparation or processing; mop sinks; janitorial/service sinks serving food processing or food preparation areas; floor drains; trench drains; indirect waste receptors in areas where grease may be present; and indirect waste from equipment that may generate or convey grease. (2) Toilets; urinals; lavatories; showers; drinking fountains; dishwashers and any discharge from dishwashers; food waste disposal units/grinder and any discharge from such units (unless the unit discharges to a separately approved interceptor specifically designed to receive such discharge, where allowed by the California Plumbing Code and approved by the public works director and building official); and any waste stream the public works director determines should remain separate shall not be connected to, or discharge through, a grease interceptor. (3) All other applicable requirements in section 23-190. (c) A food processing facility with a gravity separation interceptor or grease trap legally and properly installed prior to January 1, 1991, may be exempted subsection (b) if the following conditions are met: (1) The food processing facility demonstrates, to the satisfaction of the public works director, that the existing gravity separation interceptor or grease trap effectively removes grease; and (2) The gravity separation interceptor or grease trap is designed and installed so that it can be inspected and properly maintained. (d) Conditional waivers for the gravity separation interceptor requirement may be granted if the public works director finds all of the following: (1) The discharge will not cause harm to the POTW, and will not unreasonably or inequitably burden the operation of the POTW; (2) The discharge would not violate (a) any applicable federal categorical discharge standard; (b) any other federal, state, or local law; or (c) any agreement between the city and applicable control authority; and (3) The discharge, when considered together with discharges from other users, will not materially affect the ability of the city or control authority to meet any federal or state requirement. (e) A food processing facility seeking a conditional waiver shall submit to the public works director, in addition to any wastewater discharge permit application required by subsection (a), such a conditional waiver application, which shall include at minimum: (1) a description of operations and food processing activities; (2) an equipment list; (3) a menu or product list, as applicable; (4) a plumbing schematic, and (5) any other materials the public works director deems necessary to evaluate the application. (f) The public works director shall not grant a conditional waiver upon a finding that the installation and use of grease trap is feasible. If a conditional waiver is denied because a grease trap is feasible, the director shall require a grease trap pursuant to section 23-164 in lieu of granting a waiver. (g) Conditional waivers may be revoked for the following reasons: (1) Changes in types of food prepared; (2) Falsification of information submitted in the restaurant survey form; (3) Changes in operating hours; (4) Changes in equipment used; (5) Failure to maintain grease trap; (6) Failure to maintain building sewer; (7) Failure to comply with conditional waiver stated requirements and/or conditions; (8) Any sewer blockages and/or sanitary sewer overflows which require any response from the city, and which may be attributed to the discharge of the business; or (9) At any time the public works director makes a subsequent finding that the discharge unreasonably burdens the POTW, or materially affects the ability of the city or IEUA to meet any federal or state requirement.
(Ord. No. 1984, § 2(Exh. A), 3-10-26)
Ask a question about Fontana law
Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.