For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 23-251 — Connection required for existing and new structures

Code of the City of Fontana, California (Supp. No. 65: codified through Ordinance No. 1987, enacted April 28, 2026) · Fontana City Code § 23-251

Corpus is an independent public-information project, not the official City of Fontana website. Stable reference: corpuslaw.us/code/eb6845fa-6b47-4c33-b1a6-7cf587a7ca91

Sec. 23-251. - Connection required for existing and new structures.

(a) Connection of existing structures. The owner of any premises with an existing structure in or from which sewage is generated must connect the structure directly with the proper public sewer in accordance with the provisions of this chapter as follows: (1) The owner of any building occupied by humans situated within the city and abutting on any street or easement in which there is now located or may in the future be located a public sewer of the city which will serve the building is hereby required, at the owner's expense, to connect the building directly with the proper public sewer, within 90 days after the date of official notice to do so, provided the public sewer is within 200 feet of the nearest point of the building. For purposes of this section, the house connection sewer shall be considered a portion of the public sewer. (2) The owner of any property which is served by an OWTS must connect any structure served by that OWTS to the public sewer or obtain a permit to operate that OWTS from the Santa Ana Regional Water Quality Board if any of the following are true: a. The OWTS receives a flow of more than 10,000 gallons per day; b. The OWTS receives wastewater other than domestic wastewater from residential or commercial buildings; or c. The OWTS receives high-strength wastewater from commercial food service buildings that exceed 900 mg/L for biological oxygen demand or does not have a properly sized and functioning oil/grease interceptor (a.k.a. grease trap); d. The OWTS requires supplemental treatment under tier 3 of the OWTS policy; e. The OWTS requires and cannot comply with the corrective actions under tier 4 of the OWTS policy; or f. The OWTS consists of a cesspool. (b) Connection of new structures. The owner of any property on which a new structure is proposed for construction must connect the structure to the public sewer if sewage will be generated in or from the structure, unless all of the following are satisfied: (1) The public sewer is not available. For purposes of this section, the public sewer is not available when the property boundary is more than 200 feet away from the public sewer; and (2) The lot size is more than one-half acre (average gross) in size, or the owner obtains an exemption from this requirement from the Santa Ana Regional Water Quality Control Board; and (3) The new structure will be served by an OWTS that satisfies the tier 1 or Tier 3 standards under the OWTS policy; and (4) If the new structure is a detached accessory dwelling unit or junior accessory dwelling unit or increases the size of an existing OWTS, the Santa Ana Regional Water Quality Control Board reviews and approves the proposed OWTS. (c) Permit required. In accordance with article IV of this chapter, no person shall connect to the sewer system or construct OTWS without first obtaining a written permit from the city and paying all fees and connection charges as required therein.

(Ord. No. 1984, § 2(Exh. A), 3-10-26)

Ask a question about Fontana law

Corpus searches the Fontana sections it holds and shows the ones that match, with their citations. Free, no sign-in.